The central process data exists for different telegrams. For example, telegram 391 is used for transferring measuring times and digital inputs/outputs.

The following central process data is available: Receive signals:

 CU_STW Control Unit control word  A_DIGITAL Digital outputs

 MT_STW Probe control word Transmit signals:

 CU_ZSW Control Unit status word  E_DIGITAL Digital inputs

 MT_ZSW Probe status word

CU_STW (control word for Control Unit, CU) See function diagram [2448]

Table 4-20 Description CU_STW (control word for Control Unit)

Bit Meaning Comments BICO

0 Synchronizations flag – This signal is used to synchronize the jointsystem time between the master and slave. BI: p0681

1...6 Reserved – – –

7 Acknowledging faults 0/1 Acknowledging faults BI: p2103

8...11 Reserved – – –

12 Master sign–of–life bit 0 – 13 Master sign–of–life bit 1 –

Master sign of life CI: p2045

14 Master sign–of–life bit 2 – Master sign of life CI: p2045

15 Master sign–of–life bit 3 –

A_DIGITAL (digital outputs)

This process data can be used to control the Control Unit outputs. See function diagram [2449]

Table 4-21 Description A_DIGITAL (digital outputs)

Bit Meaning Comments BICO

0 Digital input/output 8 (DI/DO8) – DI/DO 8 on the Control Unit must be parameter-ized as an output (p0728.8 = 1). BI: p0738

1 Digital input/output 9 (DI/DO9) – DI/DO 9 on the Control Unit must be parameter-ized as an output (p0728.9 = 1). BI: p0739

2 Digital input/output 10 (DI/DO 10) – DI/DO 10 on the Control Unit must be para-meterized as an output (p0728.10 = 1). BI: p0740

3 Digital input/output 11 (DI/DO 11) – DI/DO 11 on the Control Unit must be para-meterized as an output (p0728.11 = 1). BI: p0741

4 Digital input/output 12 (DI/DO 12) – DI/DO 12 on the Control Unit must be para-meterized as an output (p0728.12 = 1). BI: p0742

5 Digital input/output 13 (DI/

DO 13) –

DI/DO 13 on the Control Unit must be para-

meterized as an output (p0728.13 = 1). BI: p0743 6 Digital input/output 14 (DI/DO 14) – DI/DO 14 on the Control Unit must be para-meterized as an output (p0728.14 = 1). BI: p0744

7 Digital input/output 15 (DI/

DO 15) –

DI/DO 15 on the Control Unit must be para-

meterized as an output (p0728.15 = 1). BI: p0745

PROFIdrive Cyclic communication

MT_STW

Control word for the ”central probe” function. Display via r0685.

Table 4-22 Description MT_STW (control word for Control Unit)

Bit Meaning Comments BICO

0 Falling edge probe 1 – Activation of measuring time determination

1 Falling edge probe 2 –

Activation of measuring time determination with the next falling edge

2...7 Reserved – –

CI: p0682 8 Rising edge probe 1 – Activation of measuring time determination CI: p0682

9 Rising edge probe 2 –

Activation of measuring time determination with the next rising edge

10...15 Reserved – –

CU_ZSW (status word for Control Unit, CU) See function diagram [2458]

Table 4-23 Description CU_ZSW (status word for Control Unit)

Bit Meaning Comments BICO

0...2 Reserved – – –

3 Fault active 1 Fault active BO: r2139 3

3 Fault active

0 No fault present BO: r2139.3

4...6 Reserved – – –

7 Alarm present 1 Alarm present BO: 2139 7

7 Alarm present

0 No alarm present BO: 2139.7

8 SYNC – – BO: r0899.8

9...11 Reserved – – –

12 Slave sign–of–life bit 0 – 13 Slave sign–of–life bit 1 –

Slave sign of life Implicity in-

14 Slave sign–of–life bit 2 – Slave sign of life

Implicity in terconnected 15 Slave sign–of–life bit 3 –

E_DIGITAL (digital inputs)

See function diagram [2459]

Table 4-24 Description E_DIGITAL (digital inputs)

Bit Meaning Comments BICO

0 Digital input/output 8 (DI/DO= 8) – DI/DO 8 on the Control Unit must be para-meterized as an input (p0728.8 = 0). BO: p0722.8

1 Digital input/output 9 (DI/DO= 9) – DI/DO 9 on the Control Unit must be para-meterized as an input (p0728.9 = 0). BO: p0722.9

2 Digital input/output 10 (DI/DO = 10) – DI/DO 10 on the Control Unit must be para-meterized as an input (p0728.10 = 0). BO: p0722.10

3 Digital input/output 11 (DI/

DO = 11) – DI/DO 11 on the Control Unit must be para-meterized as an input (p0728.11 = 0). BO: p0722.11 4 Digital input/output 12 (DI/DO = 12) – DI/DO 12 on the Control Unit must be para-meterized as an input (p0728.12 = 0). BO: p0722.12

5 Digital input/output 13 (DI/

DO = 13) – DI/DO 13 on the Control Unit must be para-meterized as an input (p0728.13 = 0). BO: p0722.13 6 Digital input/output 14 (DI/DO = 14) – DI/DO 14 on the Control Unit must be para-meterized as an input (p0728.14 = 0). BO: p0722.14

7 Digital input/output 15 (DI/

DO = 15) – DI/DO 15 on the Control Unit must be para-meterized as an input (p0728.15 = 0). BO: p0722.15 8 Digital input 0 (DI 0) – Digital input DI 0 on the Contol Unit BO: r0722.0 9 Digital input 1 (DI 1) – Digital input DI 1 on the Contol Unit BO: r0722.1 10 Digital input 2 (DI 2) – Digital input DI 2 on the Contol Unit BO: r0722.2 11 Digital input 3 (DI 3) – Digital input DI 3 on the Contol Unit BO: r0722.3 12 Digital input 4 (DI 4) – Digital input DI 4 on the Contol Unit BO: r0722.4 13 Digital input 5 (DI 5) – Digital input DI 5 on the Contol Unit BO: r0722.5 14 Digital input 6 (DI 6) – Digital input DI 6 on the Contol Unit BO: r0722.6 15 Digital input 7 (DI 7) – Digital input DI 7 on the Contol Unit BO: r0722.7

Note:

The bidirectional digital inputs/outputs (DI/DO) can be connected as either an input or an output (see also receive signal A_DIGITAL).

PROFIdrive Cyclic communication

MT_ZSW

Status word for the ”central probe” function.

Table 4-25 Description MT_ZSW (status word for the central probe function)

Bit Meaning Comments BICO

0 Digital input probe 1 –

Display of the digital inputs 1 Digital input probe 2 – Display of the digital inputs

2...7 Reserved – –

CO: r0688

8 Sub–sampling probe 1 –

Not yet carried out

CO: r0688 9 Sub–sampling probe 2 – Not yet carried out.

10...15 Reserved – –

MTn_ZS_F and MTn_ZS_S

Displays the determined measuring time

Features of the central probe

 The time stamps from probes in more than one drive can be transferred simul- taneously in a single telegram.

 The time in the controller and drive unit is synchronized via the CU_STW and the CU_ZSW.

Note: The controller must support time synchronization!

 A higher–level controller can then use the time stamp to determine the actual position value of more than one drive.

 The system outputs a message if the measuring time determination function in the probe is already in use (see also p0488, p0489, and p0580).

Example: central probe

Assumptions for the example:

 Determination of the time stamp MT1_ZS_S by evaluating the rising edge of probe 1

 Determination of the time stamp MT2_ZS_S and MT2_ZS_F by evaluating the rising and falling edge of probe 2

 Probe 1 on DI/DO9 of the Control Unit (p0680[0] = 1)  Probe 2 on DI/DO10 of the Control Unit (p0680[1] = 2)  Manufacturer–specific telegram p0922 = 391 is set

a b la u fd ia g ra m m _ ze nt r_ m es se n .v sd 1 0 MT_STW .0 1 0 Value available MT2_ZS_F 1 0 Probe 1 1 0 Probe 2 1 0 1 0 MT_STW .8 MT_STW .9 Value available MT1_ZS_S 1 0 1 0 Value available MT2_ZS_S

PROFIdrive Acyclic communication