OverviewIndustrial Twisted Pair cable
• For constructing Industrial Twisted Pair (ITP) networks
• Double cable shield for industrial use
• Easy to lay
• Low-cost connection of data terminals
• Exceeds Category 5 of the international cabling standards ISO/IEC 11801 and EN 50173
• Available as standard type and as halogen-free version (FRNC)
Industrial Twisted Pair connector
• Connector is assembled on site with screw terminals without the need for special tools
• Data transfer is noise resistant thanks to - rugged metal connector
- system-wide grounding concept
• Fast, error-free installation using factory-tested preassembled cables.
■
BenefitsData transfer is noise resistant thanks to
• double shielding with plastic and braided shield
• System-wide grounding concept
• Silicon-free, therefore suitable for use in the automotive indus-try (e.g. on paint shop conveyors)
• Available as standard and hologen-free version
■
DesignIndustrial Twisted Pair cable
• 2 x 2 cores.
• Two cores with two dummy elements twisted into a pair.
• Each pair is encased in plastic film and shielded with two aluminum-clad plastic films
• Outer braided shield around all pairs made of tinned copper wire.
• Plastic sheath (PVC).
The ITP Cable is available as a pre-assembled cable in the following versions:
• ITP Cable 9/15
with a 9-pole and a 15-pole connector. It is used to directly connect data terminals with an ITP interface to Industrial Ethernet network components with an ITP interface.
• ITP XP Standard Cable 9/9
with two 9-pole connectors. It is twisted and used to directly connect two Industrial Ethernet network components with ITP interfaces.
• ITP XP Standard Cable 15/15
with two 15-pole connectors. It is twisted and used to directly connect two data terminals with ITP interfaces.
Possible applications for pre-assembled ITP cables Industrial Twisted Pair connector (9-pole)
• Metal Sub D connector
• Vertical outgoing cable
• For connecting the 2 x 2-core installation cable to OSM or ESM
• Easy assembly using a screwdriver.
Industrial Twisted Pair connector (15-pole)
• Metal Sub-D connector
• Variable cable outlet
• For connecting the 2 x 2-core installation cable to a data terminal
• Internal plug-in jumper for automatic switchover from AUI to Twisted Pair operation in SIMATIC NET CPs with integrated Twisted Pair transceiver
• Easy assembly using a screwdriver.
■
Function• With their double, particularly dense shield, the industrial twisted pair cables are especially suitable for installation in industrial environments subject to electromagnetic inter-ference, e.g. for linking control cabinets.
• An integrated grounding concept can be implemented through the outer shield.
• The ITP cable is flame retardant and has a copolymer outer casing FRNC (Flame Retardant Non Corrosive)
• The cables considerably exceed Category 5 of the interna-tional cabling standard. They can be implemented for up to 300 MHz and are suitable for Fast Ethernet with 100 Mbit/s.
Network components
Data terminal Network components ITP XP 9/9 ITP 9/15
Data terminal ITP 9/15 ITP XP 15/15
Passive Network Components
Industrial Twisted Pair – Cables/connectors
■
Technical specifications■
Ordering data Order No.2
ITP Standard and FRNC Cable Electrical data (at 20 °C)
Damping
Near-end cross-talk attenuation
• at 1 ... 100 MHz ≥ 80 dB/100 m
• at 1 ... 300 MHz ≥ 80 dB/100 m
Coupling resistance
• at 10 MHz ≤ 2 m Ω /100 m
Operating voltage ≤ 160 V
Mechanical data
Cable type (standard designation)
• Standard J-02YSCY 2 x 2 x 0.64/1.5 PIMF F
• FRNC J-02YSCH 2 x 2 x 0.64/1.5 PIMF F
GN FRNC Internal conductor diameter
(copper)
0.64 mm
Outer diameter approx. 6.0 x 9.4 mm
(+0.3/-0.5 mm) Core cross-section acc. to AWG 22 0.64 mm Resistance (CV Ω/100 m)
acc. to AWG 22
5.3 Perm. ambient conditions
• Operating temperature -40 °C ... +80 °C
• Transport/storage temperature -40 °C ... +80 °C
• Installation temperature -25 °C ... +80 °C Permissible bending radius
• One time approx. 48 mm (standard cable)
≥ 90 mm multiple (FRNC cable)
• Multiple bends approx. 33 mm (standard cable)
≥ 60 mm single (FRNC cable) Permissible tensile force ≤ 80 N
Cu number 46 kg/km
Shield coated plastic sheet
braid: tinned copper wires, 0.20 mm Ø
approx. 90% cover Weight
• Standard approx. 90 kg/km
• FRNC approx. 98 kg/km
Halogen-free
• Standard No
• FRNC Yes
Behavior in fire
• Standard flame-retardant to
VDE 0482-265-2-1 IEC 60332-1
• FRNC flame-retardant to
VDE 0482-266-2-4 IEC 60332-3-24 Oil resistance
• Standard limited resistance to
mineral oils and grease
• FRNC limited resistance to
mineral oils and grease
Silicone-free Yes
ITP Standard Cable für Industrial Ethernet
6XV1 850-0AH10 non-assembled, sold by the meter,
2 x 2-pole, without connector for connecting a data terminal; for customer assembly with connectors or for the connection between the patch field and the outlet ITP Standard Cable 9/15 ITP installation cable for direct connection of data terminals with ITP interface to Industrial Ethernet network components with ITP interface; with one 9-pole and one 15-pole Sub-D connector
• 2 m 6XV1 850-0BH20
ITP XP Standard Cable 9/9 twisted ITP installation cable for direct connection of two Industrial Ethernet components with an ITP interface with two 9-pole Sub D connectors
• 2 m 6XV1 850-0CH20
ITP XP Standard Cable 15/15 twisted ITP installation cable for direct connection of two data ter-minals with an ITP interface with two 15-pole Sub D connectors
• 2 m 6XV1 850-0DH20
• 6 m 6XV1 850-0DH60
• 10 m 6XV1 850-0DN10
Passive Network Components
Industrial Twisted Pair – Cables/connectors
2 ■
Ordering data (continued) Order No.1) Additional language variants and manuals can be found with the various products under:
http:// www.siemens.com/automation/csi/net
■
More information Installation instructionsThe installation cable is either supplied by the meter or with pre-assembled connectors. It can be used to connect a single data terminal or two active network components (OSM/ESM).
On the network component side, 9-pole metal Sub-D connectors are used, and on the device side, 15-pole connectors are used.
The 15-pole connectors contain a special plug-in jumper which can be used by modules with integrated twisted pair transceiver to switch from AUI to twisted pair operation.
Preassembled cables are used to connect data terminals di-rectly to an active network component or for cascading active network components.
The ITP cables can also be ordered by the meter for on site as-sembly. 9-pole and 15-pole ITP connectors for assembly without special tools are available for this purpose.
The maximum cable length of a laid ITP Standard Cable is 100 m if connected directly.
ITP cables are intended only for use inside buildings.
Note:
Additional components of the SIMATIC NET wiring range can be ordered from your local contact person.
For technical advice contact:
J. Hertlein, A&D SE PS Tel.: +49(0)911/750 44 65 Fax.: +49(0)911/750 99 91
Email: [email protected]
Note:
Additional installation instructions can be found in the manual for TP and fiber-optic-networks.
ITP FRNC Cable for Industrial Ethernet
6XV1 851-0AH10 non-assembled, halogen-free,
sold by the meter, 2 x 2-pole, without connector
for connecting a data terminal; for customer assembly with connectors or for the connection between the patch field and the outlet ITP FRNC Cable 9/15 ITP installation cable for direct connection of data terminals with ITP interface to Industrial Ethernet network components with ITP interface; with one 9-pole and one 15-pole Sub-D connector
• 2 m 6XV1 851-1AH20
• 5 m 6XV1 851-1AH50
• 8 m 6XV1 851-1AH80
• 12 m 6XV1 851-1AN12
• 15 m 6XV1 851-1AN15
• 20 m 6XV1 851-1AN20
• 30 m 6XV1 851-1AN30
ITP connector ITP connector for Industrial Ethernet, 9-pole
6GK1 901-0CA00-0AA0 for connection to OLM/ELM and
OSM/ESM ITP connector for Industrial Ethernet, 15-pole
6GK1 901-0CA01-0AA0 for connection to data terminal
with ITP interface Manual for TP and fiber-optic networks Paper version network architecture, components, configurations, mounting guidelines 1)
• German 6GK1 970-1BA10-0AA0
• English 6GK1 970-1BA10-0AA1
SIMATIC NET Manual Collection 6GK1 975-1AA00-3AA0 Electronic manuals for
communication systems, communication protocols and communication products on CD-ROM
German/English