• No se han encontrado resultados

Study of comparative bioavailability among two formulations containing hydroxyzine hydrochloride in healthy volunteers after a single dose administration

N/A
N/A
Protected

Academic year: 2017

Share "Study of comparative bioavailability among two formulations containing hydroxyzine hydrochloride in healthy volunteers after a single dose administration"

Copied!
1
0
0

Texto completo

(1)

514 ISSN 0326-2383 KEY WORDS: Bioequivalence, Hydroxyzine hydrochloride, LC-MS/MS, Pharmacokinetics.

* Author to whom correspondence should be addressed. E-mail: eabib@scentryphar.com

Latin American Journal of Pharmacy

(formerly

Acta Farmacéutica Bonaerense)

Lat. Am. J. Pharm. 30

(3): 514-8 (2011)

Original Article Received: February 1, 2010 Revised version: July 1, 2010 Accepted: August 17, 2010

Study of Comparative Bioavailability Among Two Formulations

Containing Hydroxyzine Hydrochloride in Healthy Volunteers

After a Single Dose Administration

Eduardo A. JUNIOR

1,2

*, Luciana F. DUARTE

1

, Daniela A. de OLIVEIRA

1

, Tatiane A.M. STEIN

1

,

Marina M. NAKAMURA

1

, Moisés L.P. VANUNCI

1

, Silvana F. de SOUZA

1

,

Eunice M. SUENAGA

3

& Alessandro de C. CRUZ

4

1

Scentryphar Clinical Research, Av. Barão de Itapura, 885, 13020-420, Campinas-SP, Brazil.

2

Unicamp - College of Medical Sciences - Department of Medical Clinic/Cardiologia,

Rua Tessalia Vieira de Camargo, 126, 13083-970, Barão Geraldo, Campinas-SP, Brazil.

2

NUBEC/ Nucleus of Bioequivalence and Clinical Research, 4SPDM/Association for Development

of the Medicine, Rua Onze de Junho, 581, 04041-152, Vila Clementino, São Paulo-SP, Brazil.

SUMMARY. The study was performed to compare the bioavailability of two hydroxyzine hydrochloride 25 mg tablet formulation in 16 volunteers of both sexes. The study was conducted open with randomized two period crossover design and a two weeks wash out period. Plasma samples were obtained over a 96 h in-terval. Hydroxyzine concentrations were analyzed by Liquid Chromatography with Tandem Mass Spec-trometry (LC-MS/MS). Bioequivalence between the products was determined by calculating 90 % confi-dence intervals (90 % I.C) for the ratio of AUC0-t, AUC0-infand Cmaxvalues for the test and reference

products, using logarithmic transformed data. The 90 % confidence intervals were 81.89–105.85 %, 84.61–105.30 %, and 84.04–108.66 %, respectively. Since the 90 % confidence intervals for Cmax, AUC0-t

and AUC0 -infwere within the 80–125 % interval proposed by the Food and Drug Administration, it was

Referencias

Documento similar

Four identification and quantification techniques, including liquid chromatography (LC) separation coupled to (i) a diode array ultraviolet (UV(DAD)) (ii), mass spectrometer in

structure of the complex of enniatin B with KNCS.. Schematic representation of the in vivo study carried out on EN A toxicity. a) LC-MS-LIT chromatogram of the EN A present in the

In this Doctoral Dissertation, the impressive analytical power of on-line comprehensive two-dimensional liquid chromatography (LC × LC) for the separation of very complex natural

Determination of phenols in environmental water samples by ionic liquid-based headspace liquid-phase microextraction coupled with high-performance liquid chromatography.

The European guidelines for conducting bioequivalence studies of immediate-release formulations state that two formulations are bioequivalent if the 90% confidence

Yusà, Liquid chromatography- Orbitrap Tribrid high-resolution mass spectrometry using data dependent-tandem mass spectrometry with triple stage fragmentation as a screening tool

Total phenolic compounds (TPC) and antioxidant capacity (FRAP and ABTS) of broccoli stalk slices and covering liquid on day 0 (raw) and during the fermentation process (days 3 and

The authors developed a simple and rapid method based on liquid chromatography in tandem with mass spectrometry (LC/MS-MS) with solid phase extraction (SPE)