Centrifugal pumps

Top PDF Centrifugal pumps:

60 Hz 6BP SINGLE STAGE ELECTRIC CENTRIFUGAL PUMPS ELETTROPOMPE CENTRIFUGHE MONOGIRANTI ELECTROBOMBAS CENTRIFUGAS CON UNA TURBINA.

60 Hz 6BP SINGLE STAGE ELECTRIC CENTRIFUGAL PUMPS ELETTROPOMPE CENTRIFUGHE MONOGIRANTI ELECTROBOMBAS CENTRIFUGAS CON UNA TURBINA.

A COMPLETE RANGE FOR ANY NEED. SAER produces and exports more than 700 types of submersible and centrifugal pumps and motors all over the world… End suction pumps according to EN 733 in close-coupled, bareshaft and stub shaft version, end suction pumps with dimensions exceeding the norm, split casing, horizontal and vertical multistage, booster sets, pumps for residential use, radial and semi-axial submersible pumps and submersible motors: SAER offers global solutions in the water field… The products are available in different metallurgies: carbon steel, brass, cast iron, techno-polymer, several grades of stainless steel, marine bronze, DUPLEX……… with such a choice, SAER provides a products range suitable for any application…
Mostrar más

44 Lee mas

NM4, NMS4 60 Hz. Close Coupled Centrifugal Pumps n 1750 rpm Bombas centrífugas monobloc n /min. Coverage chart - Campo de aplicaciones

NM4, NMS4 60 Hz. Close Coupled Centrifugal Pumps n 1750 rpm Bombas centrífugas monobloc n /min. Coverage chart - Campo de aplicaciones

Construction Close-coupled centrifugal pumps; electric motor with extended shaft directly connected to the pump up to 15 kW, new bracket construction for standard motors (Stub-shaft construction) from 18,5 to 75 kW with integrated thrust bearing. Pump casing with axial suction and radial delivery on top, main dimensions and performance according to EN 733 with additional sizes for completion.

20 Lee mas

IE2 LPS. ELECTROBOMBA MONOBLOC IN-LINE Acero Inox. AISI 304 IN-LINE CENTRIFUGAL PUMPS in AISI 304

IE2 LPS. ELECTROBOMBA MONOBLOC IN-LINE Acero Inox. AISI 304 IN-LINE CENTRIFUGAL PUMPS in AISI 304

Adecuada en siste- mas de calefacción domésticos e Industriales, circulación de agua caliente sanitaria, sistemas de calefacción y refrigera- ción, vehiculación de líquidos a baja presió[r]

6 Lee mas

Pompe centrifughe autoadescanti Self-priming centrifugal pumps Bombas centrífugas autocebantes. J Rev. 08

Pompe centrifughe autoadescanti Self-priming centrifugal pumps Bombas centrífugas autocebantes. J Rev. 08

The air-liquid emulsion is forced into the priming chamber where the lighter air is separated and leaves through the discharge pipe; the heavier liquid drops back down into circulation. Once all of the air has been expelled from the suction pipe, the pump is primed and works like a normal centrifugal pump. The pump can also work with an air-liquid mixture.

16 Lee mas

Centrifugal Pumps. Bombas Centrífugas CLCP OWNER S MANUAL MANUAL DEL USUARIO. Call English... Pages 2-8

Centrifugal Pumps. Bombas Centrífugas CLCP OWNER S MANUAL MANUAL DEL USUARIO. Call English... Pages 2-8

For parts or troubleshooting assistance, DO NOT return product to your retail store. Contact CountyLine Customer Service at 1-800-535-4950. Claims made under this warranty shall be made by returning the product (except sewage pumps, see below) to the retail outlet where it was purchased or to the factory immediately after the discovery of any alleged defect. CountyLine will subsequently take corrective action as promptly as reasonably possible. No requests for service will be accepted if received more than 30 days after the warranty expires. Warranty is not transferable and does not apply to products used in commercial/rental applications.
Mostrar más

16 Lee mas

NM, NMS 60 Hz. Close Coupled Centrifugal Pumps with flanged connections Bombas centrífugas monobloc con bridas. Coverage chart - Campo de aplicaciones

NM, NMS 60 Hz. Close Coupled Centrifugal Pumps with flanged connections Bombas centrífugas monobloc con bridas. Coverage chart - Campo de aplicaciones

Pump casing with axial suction and radial delivery on top, main dimen- sions and performance according to EN 733. NM(S): version with pump casing and lanter bracket in cast iron. B-NM(S): version with pump casing and lanter bracket/casing cover in bronze. (the pumps are supplied fully painted).

16 Lee mas

Centrifugal electric pumps Electropompes centrifuges Fliehkraft-Pumpen Electrobombas centrífugas Elettropompe centrifughe

Centrifugal electric pumps Electropompes centrifuges Fliehkraft-Pumpen Electrobombas centrífugas Elettropompe centrifughe

Targa in acciaio inossidabile Figure 1 - Plate for single-block electrical pumps Figure 2 - Plate for pump body of detachable electrical pumps Figure 1 - Plaque pour électropompe monobloc Figure 2 - Plaque pour corps de pompe de l'électropompe amovible Abbildung 1 - Typenschild für die Monoblock Elektropumpe Abbildung 2 - Typenschild für Pumpenkörper der abnehmbaren Figura 1 - Placa para electrobomba monobloque Elektropumpe

25 Lee mas

Tests of a centrifugal pump operating as a water turbine

Tests of a centrifugal pump operating as a water turbine

The characteristic pump curves clearly show a problem related to the testing of both pumps. At a flow rate of approximately 1.7 Lps pump efficiency, total head and hydraulic power are greatly diminished, which is not the typical behavior for any centrifugal pump. This loss of head and efficiency is due to a problem regarding the test method used: the Armfield F1 has an insufficient inlet head, thus at a high flow rate cavitation occurs at the suction of the pump. Figure 20 shows that the 1A-3/4W pump behaves in a very similar fashion as to the one depicted in the manufacturer´s supplied curve up until the point where the cavitation problem arises. Thus, it is a good approximation to use the manufacturer´s curve for calculations.
Mostrar más

58 Lee mas

Uncertainty analysis of a test-rig for centrifugal compressors

Uncertainty analysis of a test-rig for centrifugal compressors

Abstract: This work stablishes the experimental procedure aimed to obtain a compressor performance map, and the description of the uncertainty propagation method in the final results of a test-rig for centrifugal compressors to improve the accuracy and therefore the precision of the experimental set-up. A mathematical method has been developed to implement all the uncertainties, errors and calibration factors of the different measuring and processing devices.

9 Lee mas

LPC 7000 PRESSURE COMPARISON TEST PUMPS MANUAL

LPC 7000 PRESSURE COMPARISON TEST PUMPS MANUAL

• Retire la tapa del depósito y llene el depósito con líquido hasta el nivel de la cisterna • Cierre la tapa y fije el tornillo de la válvula de aguja... Abrir la válvula de aguja de dep[r]

12 Lee mas

Bomba Centrífuga BC615 BC620. Centrifugal Water Pump

Bomba Centrífuga BC615 BC620. Centrifugal Water Pump

- The pump does not require maintenance as long as the following precautions are taken: when there is a risk of freezing, empty the pump by removing the suction tube, ensuring that t[r]

16 Lee mas

A Leader of Pumps for Industry

A Leader of Pumps for Industry

Las bombas monocelulares y las bombas de cámara partida son utilizadas en los sistemas de bombeo en acueductos, para el servicio de extinción de incendios y en la industria para aguas[r]

20 Lee mas

PLC BOMBAS DE ENGRANAJES GEAR PUMPS

PLC BOMBAS DE ENGRANAJES GEAR PUMPS

El dibujo aquí representado indica que la bomba es de giro derecha, para giro izquierda se sustituirá la “D” de la referencia por una “I”, en este caso los orificios de aspiración y pres[r]

24 Lee mas

71489750 Metso Pumps Manual Spanish

71489750 Metso Pumps Manual Spanish

e) La grasa de los rodamientos debería ser inspeccionada al menos cada doce meses. f) El cilindro de rodamiento debe ser desarmado, limpiado y vuelto a engrasar antes de volverlo a a[r]

137 Lee mas

Vane pumps Service information T6CC - T6CCM - T6CCP

Vane pumps Service information T6CC - T6CCM - T6CCP

Descrizione Descripcion Part N° Teil Nr. Code N° Cod. Code N° Cod. Steuerplatte Linkslauf Plaque arrière rotation gauche.. Piatto distributore post. antioraria Plato distribuidor trasero[r]

15 Lee mas

1PN Gear Pumps / Bombas de engranaje 1PN SERIE

1PN Gear Pumps / Bombas de engranaje 1PN SERIE

Floating composite bushes are used in the pumps which house the bearing liners and provide a face seal to the gears. This efficient seal is achieved by pressure loading precise areas of the bush rear face with fluid at working pressure. Special features are incorporated in the bush sealing face to compensate for operating variables such as pressure, speed and temperature. The pressure balancing system a minimum net on-load for high mechanical efficiency yet at the same time balancing a varying pressure distribution across the bush face, thus contributing to the high volumetric performance of pumps.
Mostrar más

24 Lee mas

PLUNGER PUMPS POMPE A PISTONI BOMBAS DE EMBOLOS PPB

PLUNGER PUMPS POMPE A PISTONI BOMBAS DE EMBOLOS PPB

pressure Pressione massima Presiòn màxima bar Operating pressure a range Campo di pressioni di esercizio Rango de presiones de ejercicio (bares) bar Power requirements Potenza installat[r]

8 Lee mas

PNA BOMBAS DE ENGRANAJES GEAR PUMPS

PNA BOMBAS DE ENGRANAJES GEAR PUMPS

Ancho del diente 6 H8 / Tooth width 6 H8 N.º de dientes 8 / 8 Teeth Para bombas reversibles conexión sólo ”R”, las tomas serán iguales en ambos lados y las medidas corresponderán a la toma de aspiración. In reversible pumps, threaded ports available ”R” only, both ports same dimensions that corresponds to the suction dimension.

17 Lee mas

BOMBAS DE ENGRANAJES 2P/ 2P GEAR PUMPS SERIE/ SERIES

BOMBAS DE ENGRANAJES 2P/ 2P GEAR PUMPS SERIE/ SERIES

A shaft key supplied with the pump must be hand fitted when the coupling is assembled. The key or coupling should never be fitted or removed from the shaft by hammering. This will cause internal damage to pump. Avoid misapplication of pumps equipped with splined shafts, do not insert the pump shaft directly into the rigidly supported mating shaft of a prime mover. This practice should be avoided since very high radial loads can be imposed on the pump shaft unless the concentricity of the driving and the driven shafts, when under load, is perfectly aligned.

18 Lee mas

DLX-DLXB Dosing Pumps Pompe Dosatrici DLX-DLXB

DLX-DLXB Dosing Pumps Pompe Dosatrici DLX-DLXB

In the instance where a second pulse is received before the pump unit has completed the cycle, the pump retains this external pulse within its memory and re-starts at the end of the com[r]

8 Lee mas

Show all 101 documents...