• No se han encontrado resultados

Infrared thermography

Infrared thermography applied to lower limb muscles in elite soccer players with functional ankle equinus and non-equinus condition

Infrared thermography applied to lower limb muscles in elite soccer players with functional ankle equinus and non-equinus condition

... GSE participants had a higher TA muscle temperature after exercise that non-GSE participants. The GSE groups showed a higher TA skin temperature. Therefore infrared thermography, in the way it measures skin ...

11

The usage of infrared thermography to study thermal performance of walls: a bibliographic review

The usage of infrared thermography to study thermal performance of walls: a bibliographic review

... Lerma et al. (2018) worked on a paper to promote a discussion on the opportunities and constraints of using active infrared thermography to detect air leaks. The potential is evaluated in a qualitative ...

13

Validity of inner canthus temperature recorded by infrared thermography as a non-invasive surrogate measure for core temperature at rest, during exercise and recovery

Validity of inner canthus temperature recorded by infrared thermography as a non-invasive surrogate measure for core temperature at rest, during exercise and recovery

... through infrared thermography (IRT) were successfully used for screening potential infected individuals at international airports, becoming an important primary step for mass prevention of the spread of ...

6

Damage detection in two-dimensional plates via infrared thermography

Damage detection in two-dimensional plates via infrared thermography

... active infrared thermography has been used for the detection and character- ization of defects (cavities, cracks, inclusions) in a wide range of fields, including medical [7, 15], building [13], and ...

12

Relationship between shoulder pain and skin temperature measured by infrared thermography in a wheelchair propulsion test

Relationship between shoulder pain and skin temperature measured by infrared thermography in a wheelchair propulsion test

... infrared thermography [25,26], unfortunately they do not provide demographic or IRT data. Understanding the thermographic response to wheelchair exercise in relation to SP may offer an insight into the ...

8

Infrared thermography to quantify the risk of breast cancer.

Infrared thermography to quantify the risk of breast cancer.

... special infrared cameras to produce high quality images, detecting changes in ...the infrared image, the first signs of breast cancer can be observed in the ...of thermography after injecting the ...

7

Infrared thermography as a non-destructive test for the inspection of reinforced concrete bridges: A review of the state of the art

Infrared thermography as a non-destructive test for the inspection of reinforced concrete bridges: A review of the state of the art

... Procedural factors refer to the experimental conditions and previous knowledge of the object of study; they can be minimized by using qualified thermographers to obtain data and data correction or interpretation ...

15

Skin temperature of physically active elderly and young women measured using infrared thermography

Skin temperature of physically active elderly and young women measured using infrared thermography

... Age is a key factor that influences the blood flow of the human skin, since this is controlled by the sympathetic nervous system innervation, which is greatly affected by the aging process (Kenney & Munce, 2003). An ...

7

Effect of endurance, speed and strength training on skin temperature measured by infrared thermography = Efecto del entrenamiento de resistencia, velocidad y fuerza en la temperatura de la piel a través de la termografía infrarroja

Effect of endurance, speed and strength training on skin temperature measured by infrared thermography = Efecto del entrenamiento de resistencia, velocidad y fuerza en la temperatura de la piel a través de la termografía infrarroja

... According to the Littlejohn (2008) classification of ICC values (poor: 0 – 0.39, Fair: 0.40 – 0.59, Good: 0.60 – 0.79 and Excellent: 0.80 – 1.0), our results showed excellent ICC values between the two first thermograms ...

253

Reliability of infrared thermography in skin temperature evaluation of wheelchair users

Reliability of infrared thermography in skin temperature evaluation of wheelchair users

... the infrared camera was fi xed at 2 – 3 m, depending on the height of subjects, as the aim was to match the center of the image with the geometric center of the area to be ...

6

Infrared thermography and shoulder pain in wheelchair users = Termografía infrarroja y dolor de hombro en usuarios de sillas de ruedas

Infrared thermography and shoulder pain in wheelchair users = Termografía infrarroja y dolor de hombro en usuarios de sillas de ruedas

... From all the usages of IRT, we are obviously more interested in human applications. The utilization of IRT in the clinical field in humans dates back to the 1960s, although it started to become more accessible in the ...

187

Infrared thermography studies on the photothermal effect of gold nanoparticles in water

Infrared thermography studies on the photothermal effect of gold nanoparticles in water

... In this chapter, we describe a novel IR thermography method of study on the photothermal effect in plasmonic nanoparticles immersed in dielectric media illuminated with light. As a model system was chosen a water ...

74

Use of infrared thermography as a tool to monitor skin temperature along the recovery process of an anterior cruciate ligament surgery

Use of infrared thermography as a tool to monitor skin temperature along the recovery process of an anterior cruciate ligament surgery

... Based on these results and adding our experience in the San Carlos Clinical Hospital and our conversations with rehabilitation physicians and physiotherapists, this occurs in almost all cases when patients recover from a ...

126

Detección de fallas en elementos de un tablero eléctrico para control de motores utilizando tecnología infrarroja

Detección de fallas en elementos de un tablero eléctrico para control de motores utilizando tecnología infrarroja

... Failure analysis using infrared thermography has been considered a diagnosis technique with the advantage of being non-invasive. It also provides a fast, reliable, and accurate temperature profile of any ...

98

Caracterización de procesos de infusión de resina mediante visión artificial / presentada por Ubaldo Pineda Castillo ; dirigida por [el] Dr  Fernando Sánchez López [y el] Dr  Nicolás Montés Sánchez

Caracterización de procesos de infusión de resina mediante visión artificial / presentada por Ubaldo Pineda Castillo ; dirigida por [el] Dr Fernando Sánchez López [y el] Dr Nicolás Montés Sánchez

... exploring infrared thermography, looking at its usefulness beyond its conventional use in measuring temperatures: estimating the variation in the part’s degree of cure in the process, in terms of time and ...

261

Aerodynamic analysis of an unmanned aerial vehicle with infrared camera for monitoring oil leakage in pipeline networks

Aerodynamic analysis of an unmanned aerial vehicle with infrared camera for monitoring oil leakage in pipeline networks

... The oil industry uses pipeline networks to transport oil through thousands of kilometers. Generally, these pipeline networks are built from steel and cast iron, which need regular inspections. These inspections are ...

15

Unraveling the Infrared Transient VVV WIT 06: The Case for the Origin as a Classical Nova

Unraveling the Infrared Transient VVV WIT 06: The Case for the Origin as a Classical Nova

... Three NIR spectra of VVV-WIT-06 were obtained on 2017 March 7, 26, and April 21 using the Folded Port Infrared Echellette ( FIRE ) spectrograph on the 6.5 m Magellan Baade Telescope ( Simcoe et al. 2013 ) . The ...

6

Near Infrared Counterparts to Chandra X Ray Sources Toward the Galactic Center  I  Statistics and a Catalog of Candidates

Near Infrared Counterparts to Chandra X Ray Sources Toward the Galactic Center I Statistics and a Catalog of Candidates

... our infrared/X-ray matches, we are left with only 61 and 93 hard and soft matches, respectively, which is an insufficient number of sources to determine their true dis- ...red infrared and hard X-ray ...

12

Near infrared photometry of WISE J085510 74 071442 5

Near infrared photometry of WISE J085510 74 071442 5

... The excellent spatial resolution of the WFC3 images allowed us to constrain the multiplicity nature of J0855−0714 at separa- tions ≥0.5 AU (provided the trigonometric distance of 2.2 pc). We investigated the presence of ...

9

Infrared glucose portable device

Infrared glucose portable device

... Blood and in special glucose have a key absorption wavelength that matches in the infrared spectra. This characteristic offers quite large variations whilst analysed. If blood under test has a large quantity of ...

8

Show all 195 documents...

Related subjects