Ion implantation

1020 steel coated with Ti/TiN by Cathodic Arc and Ion Implantation
... The experiment was carried out in a d-c vacuum arc system, which is schematically shown in figure 1. The discharge was produced between a cylindrical Ti cathode (60 mm in diameter) and a grounded annular Cu anode (80 mm ...
7

Estudio de guias de onda ópticas activas obtenidas por implantación de iones en cristales de YAGStudy of active optical waveguides obtained by ion implantation in YAG cristals
... This thesis presents an experimental and theoretical study of optical channel waveguides fabricated by either proton or carbon implantation in Nd:YAG crystals, and their application to the development of compact ...
170

Atomistic modeling of ion implantation technologies in silicon
... as ion implantation and annealing, for the manufacturing of ultra-shallow junctions and finFET devices ...proposed ion implantation strategies, mainly cluster and cold implants, are aimed to ...
7

TiN Coatings on Titanium Substrates Using Plasma Assisted Ion Implantation
... Plasma-Based Ion Implantation and Deposition ...the ion species to be ...the ion sheath surrounding the substrate to be accelerated across the sheath and implanted into the ...
6

Temperature effect on damage generation mechanisms during ion implantation in Si. A classical molecular dynamics study
... Nowadays cold implants are being incorporated into the fabrication process of electronic devices [1]. Ion implantation at low temperature facilitates the creation of amorphous layers at the Si substrate ...
5

Resistencia al desgaste y corrosión de AISI 316L nitrurado por dos diferentes métodos asistidos por plasma
... Immersion Ion Implantation (PIII), que es un tratamiento que consiste en la implantación de iones a altas energías sobre el contorno completo de la pieza, combinado con la difusión, y la nitruración DC, que ...
5

Corrosion resistance of AISI 316L stainless steel nitrided by three different plasma assisted techniques.
... 15 Wei R, Vajo JJ, Matossian JN, Wilbur PJ, Davis JA, Williamson DL and Collins GA. A comparative study of beam ion implantation, plasma ion implantation and nitriding of AISI 304 stainless ...
6

Development and implantation of a Thesaurus of Manufacturing Engineering terms
... The new implantation was applied to the whole degrees and subjects considered in the project. According to the improvements planned previously, students received several documents that contents detailed ...
8

Universidad de Buenos Aires Colegio Nacional de Buenos Aires
... 5.2. Equilibrio iónico: ácidos y bases fuertes, ionización del agua: Kw y pH.(Revisión), ácidos y bases débiles; constante de disociación electrolítica: cálculo de pH.(revisión). Indicadores ácidos básicos. Hidrólisis; ...
5

Permanent pacemaker implantation after transcatheter aortic valve implantation: impact on late clinical outcomes and left ventricular function.
... 13. Kappetein AP, Head SJ, Généreux P, Piazza N, van Mieghem NM, Blackstone EH, Brott TG, Cohen DJ, Cutlip DE, van Es GA, Hahn RT, Kirtane AJ, Krucoff MW, Kodali S, Mack MJ, Mehran R, Rodés-Cabau J, Vranckx P, Webb JG, ...
21

A method for ion phase space validation for below therapeutic ion fluences (by single ion tracking)
... At present HIT facility has 3 treatment rooms (Figure 3.1) plus an experimental/quality assurance beamline room. Two treatment rooms and the experimental one are equipped with horizontal fixed beamlines. In the third ...
73

N.º de electrones del ion Configuración electrónica
... i. La energía de ionización (EI) o potencial de ioniza- ción (PI) es la energía necesaria que hay que propor- cionar a un átomo, en estado fundamental y gaseoso, para arrancar el último electrón de una capa de valencia y ...
8

Estudio de guías de onda angostas por multi-implantación de iones de plataStudy of optical channel waveguides by silver ion multi-implantation
... La primera etapa comprende la simulación del índice de refracción, los parámetros trabajados en ésta etapa fueron: índice de refracción de sustrato, cambio máximo de índice de refracción y profundidad. Cada uno de estos ...
87

Percutaneous pulmonary valve implantation
... A study on the experience in Germany 27 re- viewed the results during a one year period using the Edwards SAPIEN™ pulmonic valve in 22 pa- tients. Implantation was successful in 21 (10 re- ceived a 23 mm valve and ...
8