• No se han encontrado resultados

Water vapor

First water vapor measurements over Athens, Greece, obtained by a combined Raman-elastic backscatter lidar system

First water vapor measurements over Athens, Greece, obtained by a combined Raman-elastic backscatter lidar system

... Water vapor is the most influential greenhouse gas, since it absorbs infrared radiation emitted from Earth's surface and lower atmosphere more than any other constituent, thereby causing about two third of ...

8

Remote measurement of high preeruptive water vapor emissions at Sabancaya volcano by passive differential optical absorption spectroscopy

Remote measurement of high preeruptive water vapor emissions at Sabancaya volcano by passive differential optical absorption spectroscopy

... of water vapor, but these emissions are dif fi cult to measure because they are immediately mixed into the atmosphere which also contains signi fi cant water ...volcanic water vapor ...

25

Concentration of heavy metals in condensed atmospheric water vapor at three Mexican localities

Concentration of heavy metals in condensed atmospheric water vapor at three Mexican localities

... of water vapor is a very useful technique in mitigating the scarcity of water resources for human consumption; however, the quality of this water must meet the highest standards to avoid ...

12

Validation of MODIS integrated water vapor product against reference GPS data at the Iberian Peninsula

Validation of MODIS integrated water vapor product against reference GPS data at the Iberian Peninsula

... the water vapor product from MODIS (MODerate-resolution Imaging Spectroradiometer) instrument, on-board Aqua and Terra satellites, is compared against GPS water vapor data from 21 stations in ...

29

Column water vapor determination in night period with a lunar photometer prototype [Discussion paper]

Column water vapor determination in night period with a lunar photometer prototype [Discussion paper]

... tropics and the poles. Raman Lidars and microwave radiometers are complex and ex- pensive instruments to set up a global network. Radiosondes routine operation is also rather expensive and for this reason they are flown ...

27

Validation of integrated water vapor from OMI satellite instrument against reference GPS data at the Iberian Peninsula

Validation of integrated water vapor from OMI satellite instrument against reference GPS data at the Iberian Peninsula

... integrated water vapor (IWV) measurements retrieved from the Ozone Monitoring Instrument (OMI), using as reference nine ground-based GPS stations in the Iberian ...

8

Column water vapor determination in night period with a lunar photometer prototype

Column water vapor determination in night period with a lunar photometer prototype

... the water vapor molecules (Duan et ...of water va- por (“map function”) derived from column-averaged temper- ature obtained from ...GPS water vapor program (E- ...column water ...

9

GEWEX water vapor assessment (G-VAP): final report

GEWEX water vapor assessment (G-VAP): final report

... GEWEX Water Vapor Assessment (G-VAP) which has the major purpose to quantify the current state of the art in water vapour products being constructed for climate applications and to support the ...

221

AERONET Web Data Access and Relational Database

AERONET Web Data Access and Relational Database

... This presentation describes the design, capability, and delivery of data from the AERONET web site. In early 2004, the web site was redesigned to improve readability and content in addition to meeting NASA web site ...

29

Winter aerosol and trace gas characteristics over a high-altitude station in the Western Ghats, India

Winter aerosol and trace gas characteristics over a high-altitude station in the Western Ghats, India

... and water vapor measurements were made with a Cimel Sun/Sky radiometer manufactured by M/s Cimel Electronique, ...columnar water vapor parameters from Cimel Sun/Sky radiometer data can be ...

18

Characterization of the vertical structure of the atmosphere using ground-based remote sensing (III)

Characterization of the vertical structure of the atmosphere using ground-based remote sensing (III)

... atmospheric water vapor at nighttime,WMO Technical conference o meteorological and environmental instruments and methods of observation, (TECO- 2012), Brussels (Belgium), 16-18 October ...

23

Estimation of atmospheric attenuation at 99 GHz using a total power radiometer

Estimation of atmospheric attenuation at 99 GHz using a total power radiometer

... liquid water particles found in clouds and rain ...constituents, water vapor exhibit the most important absorption characteristics, within the band, with exception of those frequencies corresponding ...

5

MOLECULAR DYNAMICS SIMULATIONS OF BUBBLE COLLAPSE AT SONOLUMINESCENCE CONDITIONS

MOLECULAR DYNAMICS SIMULATIONS OF BUBBLE COLLAPSE AT SONOLUMINESCENCE CONDITIONS

... The physical processes within collapsing bubbles are investigated by molecular dynamics simulations with up to several million particles. The chosen bubble and driving parameters cor- respond to typical conditions of ...

6

Evaluación energética y de la seguridad tecnológica ambiental en el central azucarero “Carlos Baliño”

Evaluación energética y de la seguridad tecnológica ambiental en el central azucarero “Carlos Baliño”

... El central azucarero “Carlos Baliño”, localizado en el municipio Santo Domingo, provincia Villa Clara, tiene potencial para mejorar los rendimientos agroindustriales y aportar un mayor valor a sus coproductos, con el ...

79

Mucilage from chia seeds (Salvia hispanica) : microestructure, physico chemical characterization and applications in food industry

Mucilage from chia seeds (Salvia hispanica) : microestructure, physico chemical characterization and applications in food industry

... 73 polysaccharides such as gum Arabic, modified starch and celluloses (Dickinson, 2003; Garti & Leser, 2001). Mucilage showed an EAI of 41.41± 0.104 m 2 /g with 40% oil and 4.46 ± 0.015 m 2 /g with 60 % oil. ...

146

Determinación de la higroscopicidad y comportamiento termodinámico de la madera juvenil y madura a través de sus isotermas de sorción

Determinación de la higroscopicidad y comportamiento termodinámico de la madera juvenil y madura a través de sus isotermas de sorción

... La respuesta higroscópica de la madera varía a lo largo de la dirección radial del árbol. El aumento de corta de ejemplares jóvenes y el uso de troncos de pequeños diámetros en la industria de los productos forestales, ...

323

Evaluación del Sistema de Recuperación de Condensados en la Empresa Azucarera Ignacio Agramonte

Evaluación del Sistema de Recuperación de Condensados en la Empresa Azucarera Ignacio Agramonte

... Los Organismos Centrales del Estado Cubano le prestan una atención priorizada al MINAZ. Sus fábricas de azúcar de caña poseen la característica única entre las grandes industrias, de obtener de la materia prima el ...

100

Alteration of the hydrologic cycle due to forest clearing and its consequences for rainforest succession

Alteration of the hydrologic cycle due to forest clearing and its consequences for rainforest succession

... converted land remains in sparse shrub cover. We hypothesized that the arrested conversion back to forests may reflect a nearly permanent condition associated with a rise in the water table. To evaluate this ...

9

UNIVERSIDAD NACIONAL EXPERIMENTAL “FRANCISCO DE MIRANDA” COMPLEJO ACADEMICO "EL SABINO" PROGRAMA DE INGENIERIA PESQUERA AREA DE TECNOLOGIA UNIDAD CURRICULAR: TERMODINÁMICA APLICADA

UNIVERSIDAD NACIONAL EXPERIMENTAL “FRANCISCO DE MIRANDA” COMPLEJO ACADEMICO "EL SABINO" PROGRAMA DE INGENIERIA PESQUERA AREA DE TECNOLOGIA UNIDAD CURRICULAR: TERMODINÁMICA APLICADA

... comprime vapor saturado del regrigerante, disminuye el volumen y aumenta su presión (P2 > P1) y por ende su temperatura (T2 > T1), obteniendo finalmente vapor sobrecalentado, en un proceso ...

20

Evaluación de la mejora energética de la unidad # 3 de la CTE” 10 DE OCTUBRE”

Evaluación de la mejora energética de la unidad # 3 de la CTE” 10 DE OCTUBRE”

... suministrando vapor para servicio de planta directo del generador de vapor, para evitar este problema se coordina con el despacho nacional y la carga mínima de generación de este bloque es de 40 MW, en la ...

86

Show all 2649 documents...

Related subjects