This sectionprovidestheinformationfor convertingyourtowermodelservertoa rack-mounted system.

Note: Thiskitisdesignedfor convertinganumberofdifferentmodels.Your model mightlookdifferentfromthemodelsillustrated,andsomepartsof thekitmightnot beused.

Preparing your server

Completethefollowingstepsto prepareyourserver.

1. Readthesafetyinformationbeginningonpage v,“Installationguidelines”on page 3,and“Handlingstatic-sensitivedevices”onpage3.

2. Shutdowntheserveroperating system.

3. Turn offtheserveranddisconnectallcables.

Note: Forinstructionsonhowto turnoff yourserver,refertothedocumentation thatcomeswithyourserver.

Removing the covers, bezel, and feet

Completethefollowingstepsto removethecovers, bezel,andfeetfromyour server.

1. Removetheleft-sidecover.

a. Unlock,open, andremovetheserverdoor,if necessary;then,locatethe cover-releaselatchonthefrontoftheserver.

Left-side cover

Cover-release latch

Figure2.Removingtheleft-sidecover

©Copyright IBM Corp.2004 5

b. Slide thecover-releaselatchonthefrontoftheservertotheunlocked positiontoreleasetheleft-side cover;then, slidetheleft-side covertoward therearoftheserverapproximately25mm(1 in.).Movethetopedgeofthe coveroutandthenliftthecoverofftheserver.Set theleft-side coveraside.

2. Removethebezel.

a. Pushtheblue bezel-releaselever up,asshown intheillustration.

b. Liftthebezeltabsoutoftheslots;then,pull thebezelawayfromthefrontof theserver.

Figure3.Removingtheserverbezel

3. Removetheright-sidecover.

a. Openthetwocable-restraintbracketsontherearof theserver.

b. Fromtherearoftheserver,removethescrewsthatholdtheright-sidecover inplace.(Thenumberof screwsvariesdependingonthemodel.)

Note: Youwillneedto savethescrewsremovedinthis stepforfuture use instep2conpage12.

c. Slide theright-sidecovertowardtherearoftheserverabout25mm(1in.);

then, lifttheright-sidecoverawayfromtheserver.Storetheright-sidecover for potentialfutureuse.

Screws

Cover

Figure4.Removingtheright-sidecover

Chapter2.Installingthetower-to-rackconversionkit 7

4. Removethefourfeetfromthebottomof theserver.

Statement 4:

≥18kg(39.7lb) ≥32kg(70.5lb) ≥55kg(121.2lb)

CAUTION:

Use safepracticeswhen lifting.

a. Carefullypositiontheserveronaflatsurfaceasshowninthefollowing illustration.Thefeetshouldhang overtheedgeoftheflatsurfaceto ease removal.

b. Press inontheclipsholdingthefeetinplace;then,rotate thefeetaway fromtheserver.Insomecases,youmightneeda screwdrivertoprythefeet fromtheserver.Storethefeetinasafe placefor potentialfuture use.

Feet

Figure5.Removingtheserverfeet

Relocating and installing hardware, covers, and bezel

Completethestepsinthissectionto:

v Movetheserialnumberbracket v Installthenewbottomcover

v Movethepower-switch panelto thenew location v Removetheoperatorinformationpanel

v Locatetheoperatorinformationpanelcableconnectoronthesystemboard v Installtheoperatorinformationpanelinthenew location

v Routetheoperatorinformationpanelcable v RemovetheM4screws

v InstalltwoM4screwsontheoppositesideoftheserver v Repositionthenon-hot-swapdrives

v Installtherelease-latch-bracketassemblies v Installthenewbezel

v Installthenewtopcoverandservice label v Installtherack-supportwheels

Chapter2.Installingthetower-to-rackconversionkit 9

1. Movetheserialnumberbrackettotherackpositiononthefrontof theserver.

a. Usea pairofplierstocompressthelockingtabontheserialnumber bracketandrotatethetophalfofthebracketawayfromtheserver.

b. Pullthebracketawayfromtheserver.

c. Positiontheserialnumberbracketasshowninfigure6.

d. Placethetworeartabsof theserialnumberbracketintothetwosmall openingsontheserver.

e. Rotatethetophalfof theserialnumberbrackettowardtheserverpressing thelockingtabintothematchinghole ontheserver.

Tower position

Rack position Serial

number bracket

Figure6.Removingandinstalllingthetowerserialnumberbracket

2. Installthenewbottomcoverthatcomeswiththiskitasshowninfigure7:

Statement4:

≥18kg(39.7lb) ≥32kg(70.5lb) ≥55kg(121.2lb)

CAUTION:

Usesafepracticeswhenlifting.

a. Carefullyturntheservertop-sidedownona flatsurfaceandplacethe bottomcoverontheserver.

Note: Thenewbottomcoverisdifferentfromthetopcover.

b. Alignthebottomcoverwiththeframe oftheserver;then,slidethecover towardthefront,making surethatthetabs ontherearandfrontofthe coverfitintotheslotsontherearandfrontof theserver.

Screws

Cover

Figure7.Installingthenewbottomcover

Chapter2.Installingthetower-to-rackconversionkit 11

c. Securethebottomcoverinplacewithtwo ofthescrewsthatyouremoved instep 3bonpage7.

d. Closethecable-restraintbracketsontherearof theserver.

e. Tocontinuewiththenext installationprocedure,carefullyturntheserver top-sideuponaflatsurface.

3. Movethepower-switchpaneltothenew location.

a. Removethefrontfansandhousing fromthefrontof theserver.Seethe OptionInstallationGuideorHardwareMaintenanceManualontheIBM xSeriesDocumentationCDforinformationonhowto removethefans and housing.

b. Removethepower-switchpanelbypressingdownandinwardonthetop tab.

c. Fromtheinsideoftheserver,alignthepanelwithitsnew location;then, placethesquareendof thepower-switch panelintothebottomopening.

d. Presstheotherendofthepower-switchpaneltowardthefrontofthe serveruntil itsnapsintoplace.

Tab

New location for power-switch panel

Figure8.Movingthepower-switchpanel

4. Removetheoperatorinformationpanel.

a. Pressupfirmlyonthebottomof theoperatorinformationpanelbracketat thepoint closestto thechassis.

b. Removethebracketsothatyoucanmoveitto thenew location.

5. Disconnecttheoperatorinformationpanelcablefromthesystem board connector.

Note: Check thesystem servicelabelontheservercoverto findtheoperator informationpanelcableconnectorlocationfor yourserver.

a. Locatetheoperatorinformationpanelcableconnectoronthesystem board.

b. Pullthecableallthewaythroughtheopeningat theoldpositionofthe operatorinformationpanel.

Note: Makesureyoudonotdisconnectanyothercableswhileyou completethis step.

New location for operator information panel bracket

Operator information panel bracket

Figure9.Removingtheoperatorinformationpanel

Chapter2.Installingthetower-to-rackconversionkit 13

6. Installtheoperatorinformationpanelinthenew location.

a. Placethetabbedendoftheoperatorinformationpanelbracketintothe opening,aligningtheLEDssothattheyshowthroughtheholesinthe serverfront.

Note: Theillustrationsinthis documentmightdifferslightlyfromyour hardware.

b. Pressthelatchendof thebracketthroughtheotheropeninguntil the operatorinformationpanelsnapsintoplace.

c. Reinstallthefrontfansandhousing.

Tabbed end

Position tabs in opening Position operator information panel bracket into opening

Figure10.Installingtheoperatorinformationpanelinthenewlocation

7. Routetheoperatorinformationpanelcablebetweenthenon-hot-swapdrive cageandthefrontfanassembly,sothatitisoutofthewayandwillnotbe pinched.

Attention: Makesurethecabledoes notobstruct thevent.

8. RemovethefourM4screwsfromtheserverasshown infigure 12.Save two ofthesescrewsareforuseinstep9 onthefollowingpage anddiscardthe remainingscrewsorstorethem forfutureuse.

Front of Server

Figure11.Routingtheoperatorinformationpanelcable

M4 Screws (4X)

Figure12.RemovingthefourM4screws

Chapter2.Installingthetower-to-rackconversionkit 15

9. InstalltwocoverretentionM4screwsinthetopholesontheoppositeside of theserverasshowninfigure13.Thesescrewsareused tosecurethetop coverto theserver.

M4 Screws (2X)

Figure13.InstallingtwoM4screws

10. RepositiontheCD-ROMdriveandanyotherdrivesorfiller panelsinthe non-hot-swapdrive baysfor rackoperation.

a. Unlatchtheside releaseforeach driveorfiller panel;then, pullthedrives orfillerpanelsoutof theserver.

Note: Youmightneedtodisconnectthecableswhenrepositioningthe drives.

b. Repositionthedrivessothattheyaretop-sideupandhorizontal;then, insertthedrivesintotheserver.Ifyoudisconnectedthedrive cables, reconnectthem.

c. Lookfor thetoplabelonthefiller panels;then,insertthemintotheunused bays.

Side release

Side release

Figure14.Repositioningthenon-hot-swapdrives

Chapter2.Installingthetower-to-rackconversionkit 17

11. Installtherelease-latchbracketassembliesthatcomewiththiskit.

a. Insertthebrackettabintotheslotontheleft-side oftheserveruntil the uppernotchonthebrackettabalignswiththeside oftheserver.

Note: TheleftbracketisstampedwithanL, andtherightbracketis stampedwithanR.

b. Pushthebracket upuntil theholesinthebracketalignwiththeholesinthe sideoftheserver;then,securethebracketwithtwoM3.5x 7mmscrews thatcomewiththiskit.

c. Repeatsteps11aand11bto installtheright-siderelease-latchbracket assembly.

12. Selectthetransparencyforyourserver.

a. Comparethetransparenciesinthekitagainstthetransparencyinstalledin thebezelthatwasremovedinstep2onpage6.

b. Discardthetransparencythatdoesnotmatchtheoneinstalledinthe bezel.

Bracket tab slot

Bracket tab

M3.5 screws

Figure15.Installingtherelease-latchbracketassemblies

13. Installthelensdefussers,transparency,andlensintothenewbezelthat comeswiththis kit.

a. Peeltheprotectivebackingfromthelensdefussers.

b. Fitthelensdefussersintothenotchedcutouts asshowninfigure 16.

c. Positionthetransparencyasshowninfigure16;then,fitthetransparency overthesquareholesinthebezel,usingtherecessasaguide.

d. Fitthelensover thetransparency.

Protective backing

Lens diffusers

Lens Transparency

Figure16.Installingthelensdefussers,transparency,andlens

Chapter2.Installingthetower-to-rackconversionkit 19

14. Installthenewbezel.

a. Alignthetabsonthebackofthebezelwiththetabopeningsonthefront oftheserver.

b. Swingthebezeltowardtheserverandpressuntilit snapsintoplace.

Bezel-release lever

Bezel

Figure17.Installingthenewbezel

15. Installthenewtopcoverthatcomeswiththiskit.

a. Alignthetopcoverwiththetopof theserver,about 25mm(1 in.)fromthe frontoftheserver.

b. Holdthetopcoveragainsttheserverandslideittowardthefrontuntilthe coversnapsintoplace.

Note: Ensure thatthetabs onthebackofthecoverfitintotheslotson thebackoftheserver.Besure thatthefrontedge ofthecoverisflat againsttheserver.

16. Selectthesystemservice labelandlight pathlabelforyourserver.

a. Comparethelabelsinthekitagainst thelables ontheleft-sidecoverthat wasremovedinstep1 onpage 5.

b. Discardthelabelsthatdonotmatchtheones ontheleft-sidecover.

Flange

Flange

Top cover

Left latch

Right latch

Figure18.Installingthetopcover

Chapter2.Installingthetower-to-rackconversionkit 21

17. Installthenewsystemservice labelandlight pathlabel.

a. Attachthenewsystem servicelabelforyourserverontheoutsidesurface ofthetopcover.

Note: Ensure thatthesystem servicelabelforyourserveralignswiththe labelpositionindicatorsonthetopof thecover.

b. Lineupthenew lightpathlabelwiththeremindbuttonandLEDsonthe cover;then, attachthelight pathlabelto thecover.

18. Storetheparts youremovedduringtheconversion ina safeplaceforpotential futureuse.

System ServiceInformation

ATTENTION: inutes at a time

. 1st power supply failur

e Replace power supply 1.

OVER Power supplies using more power than max rating Remove optional d

evices from the server until 'OVER' LED is no longer lit.

TEMPSyste m temperature exceeded maximum rating

If FAN LED is on, follow instruction s for that

LED.Make sur e the room temperatu

re is

not to o hot (see Insta

llation Guide).If

If one of the DIMM error LEDs on thesystem board is on, replace the DIMM

in that slot.

PCI AErro r occurred on an adapter in PCI slot 1, or one of thePCI devices integrated on the system board

If error log does not lis t the failing adapter, turn off server and remove adapter fromslot 1, restart the server to determine if theadapter failed.If problem persists, have

system serviced.

PCI CError occurred on an adapterin PCI slot 4, 5, or one ofthe PCI devices integrated on the system board

If error log does not list the failing adapter,turn off server and remove adapters fromslots 4 and 5, one at a time, restartingserver after each removal, to determinefailing adapter.If problem persists, have

system serviced.

DASD Hot-swap hard disk drive

failu re

If amber LED on a hard disk drive is on,replace the hard disk drive. If error logindicates temperature problem and thefans are working correctly, have the

system serviced.

MEMCPUPCI APCI BPCI C VRM DASDSP PS1PS2PS3NONOVERNMITEMPFAN

REMIND

PS3 3rd power supply failure

Replace power supply 3, if installed.

Fans a

Memory DIMM 4Memory DIMM 3Memory DIMM 2Memory DIMM 1

PCI Slot 1 32-bit (J44)PCI Slot 2 64-bit (J41)PCI Slot 3 64-bit (J42)PCI Slot 4 64-bit (J29)PCI Slot 5 64-bit (J30)

Label position

Figure19.Installingthesystemserviceandlightpathlabels

19. Installthetwobluerack-supportwheelsthatcomewiththiskit.

a. Locatethethreadedscrewholesontheserverasshownintheillustration.

b. Attachtherack-supportwheelstothesidesoftheserverbyrotatingthe wheelsinaclockwisedirectionintothethreadedscrewholes,neartherear oftheserver.(Thesewheelsareusedtohelp aligntheserverwhenyou installitintherackandwillberemoved later.)

20. UseChapter3,“Rackinstallationinstructions,”onpage 25andthetemplate

Documento similar