Prerequisites Before the operation, it is required to confirm:

� The number of exchange to be configured is known.

The MML Terminal window is opened.

Context By default, some data are created in the OMM system, including Country Code (CC), Mobile Country Code (MCC), Mobile Network Code (MNC), National Destination Code (NDC), and supported types. Modify the mobile data of local exchange as required.

Steps 1. If no exchange is specified, execute command SET on the MML Terminal window or select a NE from the system tree to spec-ify the exchange to be configured.

Example: Select the MSCS exchange with ID as 11 from the system tree.

SET:NEID=11;

2. Create local office mobile data as required. The command is ADD MSCCFG.

Table 35 describes the main parameters in the ADD MSCCFG command.

TABLE35 PARAMETERS IN THE ADD MSCCFG COMMAND

Parameter Name

Parameter

Description Instruction

MSC MSC number

It is a mandatory parameter, with a length ranging from 1 to 16 digits. MSC GT number is uniformly planned by the carrier for distinguishing different MSCs

VLR VLR number

It is a mandatory parameter, with a length ranging from 0 to 16 digits. VLR GT number is uniformly planned by the carrier for distinguishing different VLRs

CC Country Code

(CC)

It is an optional parameter, with a length ranging from 0 to 4 digits. Type it according to the actual conditions. The country code of China is 86

NDC National

destination code

It is an optional parameter, with a length ranging from 0 to 4 digits. Type it according to the

Parameter Name

Parameter

Description Instruction

MCC Mobile country code

It is an optional parameter, with a length ranging from 0 to 3 digits. Type it according to the actual conditions. The country code of China is 460.

MNC Mobile network code

It is an optional parameter, with a length ranging from 0 to 3 digits. Type it according to the actual conditions.

OFCTYPE Local exchange type

It is an optional parameter, including NONE (select none), LV1 (first connection center), LV2 (second connection center), and EO (mobile peer office).

Select it according to the actual conditions

SNLEN Mobile subscriber number length

It is an optional parameter. Type an integer ranging from 3 to 4, with a default of 3

PREINT International toll prefix

It is an optional parameter, with a length ranging from 0 to 4 digits, with a default of 00

PRENAT National toll prefix

It is an optional parameter, with a length ranging from 0 to 4 digits, with a default of 0

RC Area code It is an optional parameter. Do not add 0 ahead of an area code TAG Miscellaneous

tag It is an optional parameter.

NSYIND

NAS

synchronization indicator

It is an optional parameter. It ranges from 0 to 255, with a default of 255 (0xff indicates invalidity)

It is an optional parameter, with a default of SPEECH

RNCRESET Times of RNC reset

It is an optional parameter. The parameter are integers ranging from 1 to 10, with a default of 3

SUPCAPA Capabilities Of local office

It is an optional parameter, indicating the supplemental functions supported by the exchange. Options include NONE and IP

Parameter options: IP and SSP

It is an optional parameter, indicating the connection mode between the local MSCS and SCP when the IP playback is conducted

IPDLGVER

CAMEL version between IP and SCP, including options:

CAMEL2 , CAMEL3 and CAMEL4

It is an optional parameter.

Generally, it is configured as 3

SELFCIC

Local CIC (carrier identification code)

It is an optional parameter. It ranges from 0 to 6, with a default of 0

It is an optional parameter. It ranges from 0 to 6, with a default of 0

PLMNLIST Binding carrier PLMN

It is an optional parameter.

When the subscriber location update succeeds, MSCS notifies the PLMN number (a peer of MS) through Equivalent PLMNs of the LOCATION UPDATING ACCEPT message. PLMNLIST can have up to five groups of Equivalent PLMNs.

OPERATOR Carrier of local office

It is an optional parameter. The carrier of local office does not need to be configured in the background system, and it is generated according to MCC and MNC during the transmission.

CODETYPE

Default codec type of local office

It is an optional parameter, including options: G711A64 (ITUT_G711A_64) and G711U64 (ITUT_G711U_64)

SUPPCAL-LEDPBRT

PRBT support mode of called use

It is an optional parameter. The parameter indicates whether the exchange supports personalized ring back tone (PRBT) and the mode of the support. Options include NO, CALLER1 and CALLER2.

SUPPCAL-LINGPBRT

PRBT support mode of calling use, including options: NO and YES

It is an optional parameter, with a default of NO

Parameter Name

Parameter

Description Instruction

PBRTPFX Voice service PRBT prefix

It is an optional parameter, indicating the calling prefix of the PRBT defined by operator and mainly used for connection with the PRBT center.

PLAY-CWTONE

Whether to play the warning tone during the call waiting, including options: NO and YES

It is an optional parameter, with a default of NO

IPPFX IP pre-embeded

prefix It is an optional parameter

OMCPRIOR

Traffic control static data priority, including options: NO and YES

It is an optional parameter, with a default of NO

LOADTYPE

It is an optional parameter, with a default of NEXTLV

MISSCALL MissCall short message center

It is an optional parameter, indicating the number of MissCall short message center. It is made up of numeric characters with 0~16 digits

It is an optional parameter. It is made up of numeric characters with 0~16 digits

RCSKEY Remote Control Key(IGW)

It is an optional parameter. It ranges from 0 to 255, with a default of 255

RCMINLEN Minimum length of code(IGW)

It is an optional parameter. It ranges from 1 to 32, with a default of 1

RCMAXLEN Maximum length of code(IGW)

It ranges from 1 to 32, with a default of 20

RCTAG

Whether need to press '#' to end, including option NO and YES

It is an optional parameter, with a default of NO

CNID CNID

It is an optional parameter. It ranges from 0 to 4095, with a default of 0

LICOFCID Monitor Center Office

It is an optional parameter. It ranges from 0 to 3000, with a default of 0

Parameter Name

Parameter

Description Instruction

NAME Alias

It is an optional parameter, which is used to describe the local mobile date of MSCS for easy recognition

OSBDAS OSB analysis selector

It is an optional parameter, indicating the calling prefix of the multimedia PRBT defined by operator and mainly used for connection with the multimedia PRBT center. It is made up of numeric characters with 0~2000 digits

It is an optional parameter, with a default of NO

USSDPLC

It is an optional parameter, with a default of MSISDN_USSDC

IFDFTZC

It is an optional parameter, with a default of DISABLE

DFTZC Default ZoneCode

It is an optional parameter. It is made up of characters with 0~4 digits, with a default of FFFF

RDIPREFIX RDI prefix

It is an optional parameter. It is made up of characters with 0~16 digits

USRTYPE-JUDGE

Judgement of user type, including options:

NUMBER and ROAMTYPE

It is an optional parameter, with a default of NUMBER

The parameter is used to configure the rate of TUP/ISUP/BICC releasing successful call relevant to unaccessible DPC, and it is only effective for the inter-office signaling of TUP/ ISUP/BICC. It is 0 or within a range of 40~500.

Parameter Name

Parameter

Description Instruction

are not 0, if the office direction recovery is not considered (the call of the office direction is immediately released after the office direction signaling is recovered), the smaller the value is, the slower the release speed is. Thus the subscriber gets a better experience, but the time difference in the calling record and called record becomes larger.

For the end office, one is advised to set the value as 100, and the value of the end office should not exceed 200; For the tandem office, the default is 310

Example: Configure the mobile data of local exchange with the following requirements.

MSC number: 8613903023

VLR number: 8613903023

Country code: 86

Mobile country code: 460

Mobile network code: 00

Local office type: Mobile peer office

Miscellaneous tag: "SMS MT"&"SMS MO"&"LOCCIC_NOO UT"

Other parameters: default.

The specific command is as follows.

ADD MSCCFG:MSC="8613903023",VLR="8613903023",C C="86",NDC="139",MCC="460",MNC="00",OFCTYPE="EO

",SNLEN=3,PREINT="00",RC="25",TAG="SMS MT"&"SMS MO"&"LOCCIC_NOOUT",NSYIND=255,SOURCE=SPEECH,R NCRESET=3,SUPCAPA="NONE",SELFCIC="0",DEFCIC="0

",DEFNAEA=65535,CODETYPE=G711A64,SUPPCALLEDPB RT=NO,SUPPCALLINGPBRT=NO,PLAYCWTONE=NO,OMC PRIOR=NO,LOADTYPE=NEXTLV,RCSKEY=255,RCMINLEN

=1,RCMAXLEN=20,RCTAG=NO,CNID=0,LICOFCID=0,OS BDAS=0,ROAMPLC=NO,USSDPLC=MSISDN_USSDC,IFDFT ZC=DISABLE,DFTZC="FFFF",USRTYPEJUDGE=NUMBER,RE LCALLNUM=0,BICCCS=OFF,FAXDELAY=5,IGNLANOTALL OW=NO,CRD=NO,CMPBSCCODEC=FALSE;

END OF STEPS