The machine size of TNL-100ALII/120ALII/130AII is 2450.5 (2759.5) mm long, 1830 mm wide, 1725 mm high, a side wharf disposal changes to 3185.5 (3494.5) mm long, 1830 mm wide, 1725 mm high, and if added an wharf collection cart it becomes 3309.5 (3618.5) mm long, 1830 mm wide, 1725 mm high, (please refer to P.2-4-1). While installed with a back wharf accumulator it becomes 2450.5 (2759.5) mm long, 2155 mm wide, 1725 mm high, and to add a accumulator cart will become 2450.5 (2759.5) mm long, 2260 mm wide, 1725 mm high (Please refer to P.2-4-1).
Above mentioned sizes are space sizes for machine completing installation, actually, when you plan a factory layout, please take the following factors into consideration:
1. Room for in/out when installed, and for move around on the walkway.
2. The required height for up/down of the lifter or handling of the hoist.
3. When operating, the moving space for operator and working pieces in front of the machine.
4. The room for installation, for model TNL-100ALII/120ALII/130AII please refer to P.3-1-2, 3-1-3,3-1-4.
It is advised to leave at least 1 meter on the surrounding of the machine as safety walkway.
OPERATION MANUAL
NCT Ipari Elektronikai Kft. 31/82 Date: 18.02.2014
1148 Budapest, Fogarasi út 7.
Tel.: 06 1 467 6300 www.nct.hu
OPERATION MANUAL
NCT Ipari Elektronikai Kft. 32/82 Date: 18.02.2014
1148 Budapest, Fogarasi út 7.
Tel.: 06 1 467 6300 www.nct.hu
3.2. Requirements of the foundation
Any machine requires hard and steady foundation,
TNL-100ALII/120ALII/130AII is no exception, good foundation pluses accurate horizontal adjustment are two of the necessary conditions for the machine to take the precision processing capability into fully play.
In addition, to choose the site with less vibration and good ventilation and to avoid direct sunshine etc., heat influence to install TNL-100ALII/120ALII/130AII is very important.
Upon decided the site prepared for installation of this machine, please follow the figure on P.40 to work on good foundation engineer, and please pay attention to the follows:
1. The earth at the bottom of the lathe shall have resistance over 5 TONS/M.
2. The grinding stones paved at the bottom of the lathe shall have thickness over 300mm.
3. The cement filled between the grinding stones shall have thickness over 300mm.
4. No brick style concrete shall be used to stack as the cement foundation as it has very bad effects.
OPERATION MANUAL
NCT Ipari Elektronikai Kft. 33/82 Date: 18.02.2014
1148 Budapest, Fogarasi út 7.
Tel.: 06 1 467 6300 www.nct.hu
OPERATION MANUAL
NCT Ipari Elektronikai Kft. 34/82 Date: 18.02.2014
1148 Budapest, Fogarasi út 7.
Tel.: 06 1 467 6300 www.nct.hu
3.3. Requirements of the environment
Principally, this machine shall be installed under the following conditions. However, these conditions may be subject to area or seasons, if the difference is too much, you should consider other control measures:
1. Humidity: +5° C ~ +40° C.
2. Relative humidity: 30% ~ 50%(no steam shall be formed) 3. Atmosphere: no excessive dust, acid air, rotten air or salt.
4. Good ventilation, no direct sunshine and stay away from heat source.
5. Shall be at site that is away from vibration source such as keep away from punching &
cutting machine, roads with rushed traffic, etc.
6. Shall be away from electric-magnetic interference source sites such as: electric welding machinery, electric discharge processing machinery, radar station, etc.
If there is any problem, please contact our factory, agent or service centre for service.
Requirements of power source
1. Power source: 220±10% VAC(Standard); or 380 + 10% VAC(to install a transformer by our company).
2. Frequency: 60±1% Hz (Standard); or 50 + 1% Hz.
3. Wire size: 22 mm
4. The sensitivity of the breaker on testing electric leaking of the power source.
5. Grounding: The control box at the rear of this machine has an External protective conductor connection point labelled with PE, please connect with the PE conductor of the power system; the size of this conductor shall be above 22mm. If there is no PE conductor on the power system, then prepare a brass stick at meter away from the underground, and connect this grounding to the PE terminal of the control box, the resistor of the grounding shall be under 100 ohm.
6. Specification of the fuse: 75A (For Asia)
7. Oil pressure power source: The power of the oil pressure system is supplied by the machine itself, no external connection required.
8. Air compress source: General standard type no need to use air compressor, but if auto gate function added, there is an external compressing air required, the pressure is 5kg/cm2, the air consumption for each auto gate action is 1.3 litres.
3.4. Requirements of power source
1. Electric vo.ltage:220V±10%VAC (Standard) or 380±10%VAC (Transformer).
2. Electric frequency: 60±l% Hz (Standard) or 50±1% Hz.
3. Electric cable: 22 mm.
4. Inspected the leakage of electric sensitive will be 50mA.
5. Conductor inside of cabinet there will a external protective conductor mark ”PE” please connect with electric system ”PE” cable and the cable diameter will be 22mm .If electric system on ”PE” cable, please insert a brass bar on the ground and connect to the cabinet
”PE” point and the resistance will be 100 ohm below.
OPERATION MANUAL
NCT Ipari Elektronikai Kft. 35/82 Date: 18.02.2014
1148 Budapest, Fogarasi út 7.
Tel.: 06 1 467 6300 www.nct.hu
6. Fuse type: 80 A. (CE MARK)
7. Hydraulic source the standard machine do not need import the hydraulic source.
8. Pneumatic source the standard machine do not need the air compressor, if add auto door that there will be needed air compressor and the pressure is 5 Kg/cm2, one time for auto door need 1.3 litres.
OPERATION MANUAL
NCT Ipari Elektronikai Kft. 36/82 Date: 18.02.2014
1148 Budapest, Fogarasi út 7.
Tel.: 06 1 467 6300 www.nct.hu
4. TRANSPORTATION, STORAGE AND INSTALLATION