• No se han encontrado resultados

4. RESULTADOS

4.2 CICLO Y TABLA DE VIDA

9 During Straps, Quick

Disconnect Check interior and exterior quick disconnect strap fasteners for tears, fraying, or broken hardware.

Straps loose or missing. Quick disconnect fasteners broken.

10 During Stakes Ensure stakes are in good working

condition and are firmly in ground.

Stakes are missing or not serviceable.

Figure 9. Power Distribution Components. FOOT TOGGLE SWITCH CIRCUIT BREAKER ELECTRICAL RECEPTACLE CABLES QUICK RELEASE PIN BASE PLATE

Table 2. PMCS During Procedures – Continued. ITEM NO. INTERVAL ITEM TO BE CHECKED OR SERVICED PROCEDURE EQUIPMENT NOT READY/ AVAILABLE IF: 11 During Power Distribution Box and Power Panel

Stand

Check power distribution box for damage, such as deformations, loose or missing hardware, and corrosion.

Check main panel, circuit breakers, and toggle switches for proper operation.

Check for missing covers and dirt in electrical receptacles or plugs. Check cables for fraying and all assemblies for signs of shorts.

Circuit breakers and toggle switches do not operate. Cable frayed. Burn marks indicating shorts. Covers missing.

Check power panel stand for security of base plate and foot. Ensure quick release pin is present and in proper condition.

Ensure outer and inner tubes move freely.

Stand has damaged base plate or foot. Quick release pin is missing or not working.

Tubes do not slide freely.

Figure 10. Convenience Outlets.

Table 2. PMCS During Procedures – Continued. ITEM NO. INTERVAL ITEM TO BE CHECKED OR SERVICED PROCEDURE EQUIPMENT NOT READY/ AVAILABLE IF: 12 During Convenience Outlets

Check for missing covers and dirt in electrical receptacles or plugs. Check cables for fraying and all assemblies for signs of shorts.

Covers missing. Cable frayed. Burn marks indicating shorts.

CABLE

Figure 11. Light Assembly. WARNING

Lethal voltage is present when light set is connected to power source. Disconnect from power source before inspecting or repairing any electrical component. Be careful not to contact electrical connections. Electrical shock or death may result from failure to heed this warning.

Table 2. PMCS During Procedures – Continued. ITEM NO. INTERVAL ITEM TO BE CHECKED OR SERVICED PROCEDURE EQUIPMENT NOT READY/ AVAILABLE IF:

13 During Light Assembly Check lights for damage to end

caps and plastic cover, missing parts, such as power cords, and

Parts of light set missing or damaged.

STRAP CABLE ASSEMBLY

Table 3. PMCS After Procedures. ITEM NO. INTERVAL ITEM TO BE CHECKED OR SERVICED PROCEDURE EQUIPMENT NOT READY/ AVAILABLE IF:

Figure 12. Fabric Assembly.

1 After Fabric Assembly

(Roof, Wall) Check for tears, punctures, rips, and seams that may have separated in walls, liners, and floor.

Fabric ripped or torn. Separated seams or fabric punctures.

2 After Grommets Check for grommets that are torn

away from or out of material. Grommets are missing or torn away from material causing fabric to tear.

3 After Slide Fasteners Check for smooth operation,

missing teeth and separated seams. Slide fastener binds, does not open or close, or is torn away from fabric.

4 After Hook and Pile

Fastener Inspect hook and pile fasteners for proper alignment and cleanliness. Remove dirt by brushing fastener strips.

Fasteners do hot hold when pressed

together. Strips loose.

5 After Zipper Check for proper operation. Zipper does not move

freely.

6 After Tent Lines Inspect tent lines for cuts or fraying. Tent lines are cut,

frayed, or excessively worn.

7 After Tent Line Slips Inspect for broken tent line slips. Tent line slips broken

Table 3. PMCS After Procedures – Continued. ITEM NO. INTERVAL ITEM TO BE CHECKED OR SERVICED PROCEDURE EQUIPMENT NOT READY/ AVAILABLE IF:

8 After Straps Check interior and exterior straps

for fraying or tears.

Straps loose or missing.

9 After Straps, Quick

Disconnect

Check interior and exterior quick disconnect strap fasteners for tears, fraying, or broken hardware.

Straps loose or missing. Quick disconnect fasteners broken.

10 After Stakes Ensure stakes are in good working

CARRYING HANDLE

Figure 13. Transport Bags.

FRAME

TRANSPORT BAG

TENT PINT CONTAINER TRANSPORT BAG

FABRIC TRANSPORT BAG

Table 3. PMCS After Procedures – Continued. ITEM NO. INTERVAL ITEM TO BE CHECKED OR SERVICED PROCEDURE EQUIPMENT NOT READY/ AVAILABLE IF:

11 After Transport Bags Check frame and fabric transport

bags and tent pin container for rips, tears, or splitting seams.

Check strap assemblies for fraying or missing/broken hardware. Check carrying handles for excessive fraying.

Bags are ripped. Straps are loose. Broken hardware. Handles ripped.

Figure 14. Frame Components.

UPPER ARCH

QUICK RELEASE PIN

CABLE HEADER HITCH CLIP PIN LOWER ARCH BINDING STRAP ASSEMBLY PURLIN

Table 3. PMCS After Procedures – Continued. ITEM NO. INTERVAL ITEM TO BE CHECKED OR SERVICED PROCEDURE EQUIPMENT NOT READY/ AVAILABLE IF: 12 After Frame

Components Check condition of upper arch, cable header, lower arch, purlin, and tent threshold.

Sectional arch does not fold, locking tabs on purlin and door sill do not rotate and lock. Look for bends, cracks or other

damage. Check for free movement.

Ensure quick release pins and hitch clip pins are present and in proper working order.

Inspect binding strap assembly for fraying and presence of buckles.

Quick release pins and hitch clip pins are missing or broken.

Figure 15. Power Distribution Components. TOGGLE SWITCH CIRCUIT BREAKER ELECTRICAL RECEPTACLE BASE PLATE HANDLE FOOT QUICK RELEASE PIN

Table 3. PMCS After Procedures – Continued. ITEM NO. INTERVAL ITEM TO BE CHECKED OR SERVICED PROCEDURE EQUIPMENT NOT READY/ AVAILABLE IF:

13 After Cables Check cable assemblies for frayed

cables or damage to swaged ends. Cable assemblies frayed, damaged or missing.

14 After Handles Check fittings (handles) for damage. Cracked or broken

fittings. Handles inoperable.

15 After Power Distribution

Box and Power Panel Stand

Check power distribution box for damage to circuit breakers and toggle switches.

Check for missing covers and dirt in electrical receptacles or plugs. Check cables for fraying and all assemblies for signs of shorts.

Circuit breakers and toggle switches do not operate. Covers missing. Cable frayed. Burn marks indicating shorts.

Check power panel stand for security of base plate and foot. Ensure quick release pin is present and in proper condition.

Ensure outer and inner tubes move freely.

Stand has damaged base plate or foot. Quick release pin is missing or not working.

Tubes do not slide freely.

Figure 16. Convenience Outlets. Table 3. PMCS After Procedures – Continued. ITEM NO. INTERVAL ITEM TO BE CHECKED OR SERVICED PROCEDURE EQUIPMENT NOT READY/ AVAILABLE IF: 16 After Convenience

Outlets Check for missing covers and dirt in electrical receptacles or plugs. Check cables for fraying and all assemblies for signs of shorts.

Covers missing. Cable frayed. Burn marks indicating shorts.

COVER

Figure 17. Light Assembly. WARNING

Lethal voltage is present when light set is connected to power source. Disconnect from power source before inspecting or repairing any electrical component. Be careful not to contact electrical connections. Electrical shock or death may result from failure to heed this warning.

Table 3. PMCS After Procedures – Continued. ITEM NO. INTERVAL ITEM TO BE CHECKED OR SERVICED PROCEDURE EQUIPMENT NOT READY/ AVAILABLE IF:

17 Before Light Assembly Check lights for damage to end

caps and plastic cover, missing parts, such as power cords, and presence of fluorescent bulbs.

Parts of light set missing or damaged.

STRAP

CABLE ASSEMBLY

STANDARD INTEGRATED COMMAND POST SYSTEM (SICPS), MEDIUM NSN: 8340-01-516-0904, GREEN

NSN: 8340-01-516-0903, TAN

Documento similar