AutoDimensionBox

Default value: No Allowed values: No, Yes

Controls boxes around rolling offset automatic dimensions when using Automatic . When set to Yes, a box is drawn for the rolling offset.

For more information, see Automatic (on page 196).

BomBoltControl

Default value: 0

Allowed values: 0, 1, 2, or 3

Specifies bolt placement in the Plant ISOGEN bill of material schedules.  0 - Places the quantity for a set in the pre-CADWorx 2002 format, such as:

QUANTITY = 4, ALPHA_SIZE = 3/4", LONG_DESC = (8) Studs with nuts

 1 - Places the quantity for total bolts, and strips the set number from the long description, such as:

QUANTITY = 32, ALPHA_SIZE = 3/4", LONG_DESC = Studs with nuts

 2 - Places the quantity for a set, the alpha size based on the flange size, and appends the bolt diameter to the long description, such as:

QUANTITY = 4, ALPHA_SIZE = 12", LONG_DESC = (8) 3/4" Studs with nuts.

 3 - Places the quantity for total bolts, strips the set number from the long description, places the alpha size based on the flange size, and appends the bolt diameter to the long

description, such as:

QUANTITY = 32, ALPHA_SIZE = 12", LONG_DESC = 3/4" Studs with nuts

When this option is set to 1 or 3, the long description of the bolt must contain the number of bolts in the set enclosed by parenthesis. The software uses the value in parenthesis as the new quantity. The number is then automatically removed from the long description when displayed in the material list.

32

CADWorx Plant User's Guide

BomScheduleDirection

Default value: Yes

Allowed values: No or Yes

Specifies the direction of the bill of materials schedule.

 No - Places the bill of materials schedule in the upward direction, with the column headings at the bottom.

 Yes - Places the bill of materials schedule in the downward direction, with the column headings at the top.

BomScheduleSpacing

Default value: 0.25

Allowed values: Positive real

Controls the spacing on the bill of material schedule.

BomTagGridFactor

Default value: 1.0

Allowed values: Positive real

Controls the bill of material tag grid density on the drawing.

When BomTagOptimize (on page 32) is set to 2, set this variable to 0.5, 1.0, 2.0, or 3.0.

BomTagOptimize

Default value: 2

Allowed values: 0, 1, or 2

Specifies the tagging algorithm used for the bill of material.  0 - The tagging algorithm is off.

 1 - The algorithm is on, but does not stack any tags.

 2 - The algorithm is on. Flange, bolt, and gasket tags are stacked.

BomTagRadiusFactor

Default value: 1.25

Allowed values: Positive real

Controls the radius of tag bubbles. Bubbles are sized using this factor multiplied by the AutoCAD setvar TEXTSIZE.

BomTagSpacingFactor

Default value: 1.25

Allowed values: Positive real

Controls how far bill of materials bubbles are spaced from the model or components within the drawing.

CADWorx Plant User's Guide

33

BoltRoundControl

Default value: 0

Allowed values: 0, 1, 2, or 3

Specifies the rounding for bolt length calculations.  0 - No rounding is performed.

 1 - Rounds the value up to the nearest multiple of the value specified in Catalog.  2 - Rounds the value down to the nearest multiple of the value specified in Catalog.  3 - Rounds the value up or down to the nearest multiple of the value specified in Catalog.

CADWorxMaterial

Default value: No

Allowed values: No or Yes

Controls CADWorx material generation when using System In . For more information, see

System In (on page 174).

 No - The software bases component descriptions in CADWorx on the material types in CAESAR II. The CADWorx component name is combined with the CAESAR II material type.  Yes - The software bases component descriptions in CADWorx on the specifications.

Material types from CAESAR II are ignored.

The component name is defined in the [Product Folder]\Plant\System\Prgm.tbl file.

CAESARMaterial

Default value: 0

Allowed values: 0, 1, or 2

Controls CAESAR II material generation when using System Out . For more information, see

System Out (on page 152).

 0 - Provides extended material database material types in CAESAR II based on the pipe material defined in Spec Editor . This does not apply if the component was originally created in CAESAR II.

 1 - Provides basic material types in CAESAR II (1-17) corresponding to the component material long description in the specification.

 2 - Provides extended material database material types in CAESAR II based on the actual component material long description in the specification.

When using CAESAR II version 3.23, only option 1 can be used.

CAESARMemory

Default value: 12.0

Allowed values: Positive real

Specifies the amount of computer RAM used when importing a large CAESAR II input model. This variable is not required, but is helpful if the import is failing. The value is multiplied by megabytes.

CAESARTolerance

Default value: 0.001

Allowed values: Positive real

Specifies the tolerance for items that are not transferring correctly to CAESAR II. For example, hangers placed on a skewed line sometimes fail and require a larger tolerance factor.

34

CADWorx Plant User's Guide

CAESARVersion

Default value: 5.20

Allowed values: 5.20 or 2011

Specifies the format of the CAESAR II .c2 input file created by CADWorx. The value should match the version of CAESAR II that you are using.

DataBaseCodesISOGEN

Default value: No

Allowed values: No or Yes

Specifies how CADWorx ISOGEN uses the DataBaseCodes system.

 No - The DataBaseCodes system is not used. CADWorx Plant creates generic item code combinations for each run of ISOGEN, starting at 1 for each run. Components with identical long annotation and specification file names are given the same item-code combination.  Yes - ISOGEN uses the DataBaseCodes system.

If this option is set to Yes and a valid DataBaseCodes system is not established, bill of material generation within ISOGEN is not correct.

DimensionsExcludedSlope

Default value: 10.0

Allowed values: Positive real

Specifies the minimum percentage slope (rise/run) for automatic dimensioning of the vertical leg of sloped pipe when using Automatic . If the pipe slope is under the specified value, then the vertical leg dimension and the associated hatched graphics for the rise are not placed. The horizontal dimension is still placed.

For more information, see Automatic (on page 196).

DimensionsExistingISOGEN

Default value: 0

Allowed values: 0, 1, or 2

Controls ISOGEN isometric representation of existing components.

 0 - Existing components are exported with dotted lines and are dimensioned.  1 - Existing components are exported with dotted lines and are not dimensioned.  2 - Existing components are exported with solid lines and are dimensioned.

Individual ISOGEN dimension settings override this setting. For more information, see

ISOGEN Data Dialog Box (on page 64).

ElbowCenterLine

Default value: 0

Allowed values: 0 (off) or 1 (on)

Controls square elbow centerlines on elbow-type components. When set to 1, an additional square centerline is drawn without drawing square elbow graphics. These lines appear in 2D double line and Isometric modes only.

You can also control this variable by setting the Elbow Centerline in CADWorx Plant menu: Utilities > Drawing Control > Elbow Centerline.

CADWorx Plant User's Guide

35

FittingWidth

Default value: 1.0

Allowed values: Positive real

Specifies the appearance of all flanged, socket welded, and threaded fittings. When set to 1.0, the software draws fitting hubs or flange ODs at 100% of the width specified in their data file. This variable is useful at a value of 0.7 when drawing socket weld and threaded type hub fittings where the hubs overlap.

HVACLibraryDirectory

Default value: [Product Folder]\Plant\HVAC Allowed values: Valid directory name

Defines the location of the data files folder used for HVAC components.

ISOGENDefaultStyle

Default value: <none>

Allowed values: Full path to an Isogen.fls file

Specifies the ISOGEN style used by ISOGEN Out and ISOGEN Batch .

For more information, see ISOGEN Out (on page 104) and ISOGEN Batch (on page 106). When this variable is defined, ISOGEN Out does not display the Select ISOGEN

Style dialog box.

LanguageFile

Default value: English.dic

Allowed values: A valid and properly formatted language file

Specifies the language of all Plant dialog boxes and prompts. The specified file must be present in the [Product Folder]\Plant\Support folder for proper operation of Plant.

LayerByLineNumber

Default value: 0

Allowed values: 0, 1, 2, 3, and 4

Specifies the layers for component placement.  0

a. Solid:

i. the layer name of the solid is based on PRJ layer entry.

ii. "_" is placed in front of the layer name: For example: 150 spec is on layer _150. iii. The color of the solid is set according to the table below:

Component level color PRJ

Spec level color PRJ

Spec layer color in model DWG file Entity Color Set to By

Layer

Same Color Same Color Same Color

Entity Color Set to component level PRJ

Same Color Same Color Different Color

Entity Color Set to By Layer

Same Color Different Color Same Color

Entity Color Set to component level PRJ

36

CADWorx Plant User's Guide