The purpose of this activity is to create an output condition record for Inventory Management.
Procedure
1. Access the activity using one of the following navigation options:
Transaction code MN21
IMG menu Materials Management Inventory Management and Physical Inventory Output Determination Maintain Conditions 2. In the Choose Activity dialog box, double click Create Condition: Inventory Mgmt.
3. On the Create Output-Condition records: Inventory Management. screen, enter output type WA01 and choose Enter.
4. On the Create Condition Records (GI Note Vers.1): Fast Entry screen, enter the following values and choose Enter:
Field name Description User action and values Note Trans./Event
Type WA
Print Version 1
Print Item 1 Printing of document
item
Print Item 6 Printing of document
6. On the Create Condition records (RFQ): Communication screen, make the following entries:
Field name Description User action and values Note
Output Device LP01
8. Go back to the Create Output-Condition Records: Inventory Management screen, enter output type WA02 and choose Enter.
9. On the Create Condition Records (GI Note Vers.2): Fast Entry screen, enter the following values and choose Enter:
Field name Description User action and values Note Trans./Event
Type WA
Print Version 2
Print Item Printing of document
Print Item Printing of document
10. Choose Communication.
11. On the Create Condition Records (RFQ): Communication screen, make the following entries:
Field name Description User action and values Note
Output Device LP01
13. Go back to the Create Output-Condition records: Inventory Management screen, enter output type WA03 and choose Enter.
14. On the Create Condition Records (GI Note Vers.3): Fast Entry screen, enter the following values and choose Enter:
Field name Description User action and values Note Trans./Event
Type WA
Print Version 3
Print Item Printing of document
Print Item Printing of document
16. On the Create Condition Records (RFQ): Communication screen, make the following entries:
Field name Description User action and values Note
Output Device LP01
Number of
messages 1
Print X select
immediately Release after
output X select
17. Save your entries.
18. Go back to the Create Output-Condition Records: Inventory Management screen, enter output type WE01 and choose Enter.
19. On the Create Condition Records (GR Note Vers.1): Fast Entry screen, enter the following values and choose Enter:
Field name Description User action and values Note Trans./Event
Type WE
Print Version 1
Print Item Printing of document
Print Item Printing of document
21. On the Create Condition Records (RFQ): Communication screen, make the following entries:
Field name Description User action and values Note
Output Device LP01
22. Save your entries.
23. Go back to the Create Output-Condition Records: Inventory Management screen, enter output type WE02 and choose Enter.
24. On the Create Condition Records (GR Note Vers.2): Fast Entry screen, enter the following values and choose Enter:
Field name Description User action and values Note Trans./Event
Type WE
Print Version 2
Print Item Printing of document
Print Item Printing of document
26. On the Create Condition Records (RFQ): Communication screen, make the following entries:
Field name Description User action and values Note
Output Device LP01
28. Go back to the Create Output-Condition Records: Inventory Management screen, enter output type WE03 and choose Enter.
29. On the Create Condition Records (GR Note Vers.3): Fast Entry screen, enter the following values and choose Enter:
Field name Description User action and values Note Trans./Event
Type WE
Print Version 3 Print Item Printing of
document
Print Item Printing of document
31. On the Create Condition Records (RFQ): Communication screen, make the following entries:
Field name Description User action and values Note
Output Device LP01
33. Go back to the Create Output-Condition Records: Inventory Management screen, enter output type WF01 and choose Enter.
34. On the Create Condition Records (GR Prod. Ord. Vers.1): Fast Entry screen, enter the following values and choose Enter:
Field name Description User action and values Note Trans./Event
Type WF
Print Version 1
Print Item Printing of document
Next Item Line
Doc. Type WF
Print Version 1
Print Item Printing of document
36. On the Create Condition Records (RFQ): Communication screen, make the following entries:
Field name Description User action and values Note
Output Device LP01
38. Go back to the Create Output-Condition Records: Inventory Management screen, enter output type WF02 and choose Enter.
39. On the Create Condition Records (GR Prod. Ord. Vers.2): Fast Entry screen, enter the following values and choose Enter:
Field name Description User action and values Note Trans./Event
Type WF
Print Version 2
Print Item Printing of document
Print Item Printing of document item
2
Medium Message
transmission 1
medium
Date/Time Dispatch time 4 40. Choose Communication.
41. On the Create Condition Records (RFQ): Communication screen, make the following entries:
Field name Description User action and values Note
Output Device LP01
43. Go back to the Create Output-Condition Records: Inventory Management screen, enter output type WLB1 and choose Enter.
44. On the Create Condition Records (GI Note RP. Vers.1): Fast Entry screen, enter the following values and choose Enter:
Field name Description User action and values Note Trans./Event
Type WA
Print Version 1
Print Item Printing of document item
46. On the Create Condition Records (RFQ): Communication screen, make the following entries:
Field name Description User action and values Note
Output Device LP01
47. Save your entries.
48. Go back to the Create Output-Condition Records: Inventory Management screen, enter output type WLB2 and choose Enter.
49. On the Create Condition Records (GI Note RP. Vers.2): Fast Entry screen, enter the following values and choose Enter:
Field name Description User action and values Note Trans./Event
Type WA
Print Version 2
Print Item Printing of document
item 3
51. On the Create Condition Records (RFQ): Communication screen, make the following entries:
Field name Description User action and values Note
Output Device LP01
53. Go back to the Create Output-Condition Records: Inventory Management screen, enter output type WLB3 and choose Enter.
54. On the Create Condition Records (GI Note RP. Vers.2): Fast Entry screen, enter the following values and choose Enter:
Field name Description User action and values Note Trans./Event
Type WA
Print Version 3
Print Item Printing of document item
55. Choose Communication.
56. On the Create Condition Records (RFQ): Communication screen, make the following entries:
Field name Description User action and values Note
Output Device LP01
The condition records are created. For the following output types, the output messages are generated automatically: WA01, WA02, WA03, WE01, WE02, WE03, WF01, WF02, WLB1, WLB2, WLB3.