Horizontal forces acting on buildings—for example, those due to wind or seismic action—can be resisted by a variety of means. Rigid-frame resistance of the structure, augmented by the contribution of ordinary masonry walls and partitions, can provide for wind loads in many cases. However, when heavy horizontal loading is likely—such as would result from an earthquake—reinforced concrete

shear walls are used. These may be added solely to resist horizontal forces; alternatively, concrete walls enclosing stairways or elevator shafts may also serve as shear walls.

Figure4.30shows a building with wind or seismic forces represented by arrows acting on the edge of each floor or roof. The horizontal surfaces act as deep beams to transmit loads to vertical resisting

FIGURE 4.30: Building with shear walls subject to horizontal loads: (a) typical floor; (b) front elevation; (c) end elevation.

elements A and B. These shear walls, in turn, act as cantilever beams fixed at their base to carry loads down to the foundation. They are subjected to (1) a variable shear, which reaches maximum at the base, (2) a bending moment, which tends to cause vertical tension near the loaded edge and compression at the far edge, and (3) a vertical compression due to ordinary gravity loading from the structure. For the building shown, additional shear walls C and D are provided to resist loads acting in the log direction of the structure.

The design basis for shear walls, according to the ACI Code, is of the same general form as that used for ordinary beams:

Vu ≤ φVn (4.141)

Vn = Vc+ Vs (4.142)

Shear strengthVnat any horizontal section for shear in plane of wall should not be taken greater than 10pfc0hd. In this and all other equations pertaining to the design of shear walls, the distance of d may be taken equal to 0.8lw. A larger value ofd, equal to the distance from the extreme compression face to the center of force of all reinforcement in tension, may be used when determined by a strain compatibility analysis.

The value ofVc, the nominal shear strength provided by the concrete, may be based on the usual equations for beams, according to ACI Code. For walls subjected to vertical compression,

Vc= 2pfc0hd (4.143)

and for walls subjected to vertical tensionNu, Vc= 2  1+ Nu 500Ag  p fc0hd (4.144)

whereNuis the factored axial load in pounds, taken negative for tension, andAgis the gross area of horizontal concrete section in square inches. Alternatively, the value ofVcmay be based on a more detailed calculation, as the lesser of

Vc= 3.3pfc0hd +N4lud w (4.145) or Vc= " 0.6pfc0+lw 1.25 p fc0+ 0.2Nu/lwh Mu/Vu− lw/2 # hd (4.146)

Equation4.145corresponds to the occurrence of a principal tensile stress of approximately 4pfc0at the centroid of the shear-wall section. Equation4.146corresponds approximately to the occurrence of a flexural tensile stress of 6pfc0at a sectionlw/2 above the section being investigated. Thus the two equations predict, respectively, web-shear cracking and flexure-shear cracking. When the quantity Mu/Vu− lw/2 is negative, Equation4.146is inapplicable. According to the ACI Code, horizontal sections located closer to the wall base than a distancelw/2 or hw/2, whichever less, may be designed for the sameVcas that computed at a distancelw/2 orhw/2.

When the factored shear forceVudoes not exceedφVc/2, a wall may be reinforced according to the minimum requirements given in Sec. 12.1. WhenVuexceedsφVc/2, reinforcement for shear is to be provided according to the following requirements.

The nominal shear strengthVs provided by the horizontal wall steel is determined on the same basis as for ordinary beams:

Vs =Avsfyd

2

(4.147) whereAvis the area of horizontal shear reinforcement within vertical distances2, (in.2),s2is the vertical distance between horizontal reinforcement, (in.), andfyis the yield strength of reinforcement, psi. Substituting Equation4.147into Equation4.142, then combining with Equation4.141, one obtains the equation for the required area of horizontal shear reinforcement within a distances2:

Av= (Vu− φVφf c) s2

yd (4.148)

The minimum permitted ratio of horizontal shear steel to gross concrete area of vertical section,ρn, is 0.0025 and the maximum spacings2is not exceedlw/5, 3h, or 18 in.

Test results indicate that for low shear walls, vertical distributed reinforcement is needed as well as horizontal reinforcement. Code provisions require vertical steel of areaAhwithin a spacings1, such that the ratio of vertical steel to gross concrete area of horizontal section will not be less than

ρn = 0.0025 + 0.5  2.5 −hw lw  (ρh− 0.0025) (4.149)

nor less than 0.0025. However, the vertical steel ratio need not be greater than the required horizontal steel ratio. The spacing of the vertical bars is not to exceedlw/3, 3h, or 18 in.

Walls may be subjected to flexural tension due to overturning moment, even when the vertical compression from gravity loads is superimposed. In many but not all cases, vertical steel is provided, concentrated near the wall edges, as in Figure4.31. The required steel area can be found by the usual methods for beams.

The ACI Code contains requirements for the dimensions and details of structural walls serving as part of the earthquake-force resisting systems. The reinforcement ratio,ρv(= Asv/Acv; whereAcv is the net area of concrete section bounded by web thickness and length of section in the direction of

FIGURE 4.31: Geometry and reinforcement of typical shear wall: (a) cross section; (b) elevation.

shear force considered, andAsvis the projection onAcvof area of distributed shear reinforcement crossing the plane ofAcv), for structural walls should not be less than 0.0025 along the longitudinal and transverse axes. Reinforcement provided for shear strength should be continuous and should be distributed across the shear plane. If the design shear force does not exceedAcvpfc0, the shear reinforcement may conform to the reinforcement ratio given in Sec. 12.1. At least two curtains of reinforcement should be used in a wall if the in-plane factored shear force assigned to the wall exceeds 2Acvpfc0. All continuous reinforcement in structural walls should be anchored or spliced in accordance with the provisions for reinforcement in tension for seismic design.

Proportioning and details of structural walls that resist shear forces caused by earthquake motion is contained in the ACI Code Sec. 21.7.3.