Defines the logical structure of the schematic, that is, the assignment of a plot frame to a page determines the header, page size, and the division into rows and columns.

There are additional special texts available, the row and column texts.

Copying Existing Plot Frames

Utilities > Master data > Plot frame > Copy

EPLAN ELECTRIC P8 Basic Training

Select the plot frame you want to copy, create a new name you’re your copied plot frame and then click open.

EPLAN ELECTRIC P8 Basic Training

Creating New Plot Frames

Utilities > Master data > Plot frame > New

EPLAN ELECTRIC P8 Basic Training

Create a new name for your Plot Frame and Click Save.

Set the setting for your new plot frame and click OK

To create what

EPLAN ELECTRIC P8 Basic Training

To displayed information in the plot frame, go to

Insert > Special Text > Project Properties/ Page Properties

By pressing the icon, you can choose the properties available.

EPLAN ELECTRIC P8 Basic Training

Choose the properties you want to displayed and click OK

EPLAN ELECTRIC P8 Basic Training

Make sure the properties you choose is correct. Then Press OK

Place where you want the properties to be appear in the plot frame.

EPLAN ELECTRIC P8 Basic Training

Once the plot frames is completed, just close the screen. It’s auto save.

3. Symbols

Utilities > Master data > Symbol library > New

Firstly, if you are created a symbol in the totally new symbol libraries, follow the step as below. If you want to create a symbol in a existing symbol libraries, ignore step 1, 2 and 3 below.

EPLAN ELECTRIC P8 Basic Training

Create a name for your symbol libraries

Click OK

EPLAN ELECTRIC P8 Basic Training

To create a new symbol,

Utilities > Master data > Symbol > New

Select a variant for the symbol and click OK

EPLAN ELECTRIC P8 Basic Training

Type in a symbol name and the symbol description and click the icon to define the symbol categories.

EPLAN ELECTRIC P8 Basic Training

Select the category your symbol will fall into. Let said that I want to create a coil, go to Coils, contacts, and protective circuits, select the appropriate attributes for the particular symbols.

EPLAN ELECTRIC P8 Basic Training

Select OK

EPLAN ELECTRIC P8 Basic Training

The button is the insertion point of the symbol, you can used the free graphics drawing to help you to designed the symbol.

Example of a designed symbols.

Free Graphics Drawing

EPLAN ELECTRIC P8 Basic Training

Now right click on top frame toolbar and activate the symbol editor toolbar.

the connection point for the symbol.

Symbol Editor Toolbar

EPLAN ELECTRIC P8 Basic Training

To displayed the properties such as technical characteristics, counter, identifier when you insert your symbol in your design in future,

Insert > Properties Text

Or

In the placement of properties dialog, press the button.

EPLAN ELECTRIC P8 Basic Training

Choose what are the properties you want to displayed and click OK.

EPLAN ELECTRIC P8 Basic Training

Once OK

Press the OK button.

EPLAN ELECTRIC P8 Basic Training

To have different variants in the symbol

Go to Utilities > Master Data > Symbol > New Variant.

Choose the variant you want and click OK

EPLAN ELECTRIC P8 Basic Training

Select how you want the new variant to be rotated. Example Variant A rotated by 900. Continue the same step for different type of variant.

EPLAN ELECTRIC P8 Basic Training

Click the button if you have satisfied with your symbol.

Now go to

Option > Setting > Projects > Project Name > Management > Symbol Libraries

EPLAN ELECTRIC P8 Basic Training

Press the button,

EPLAN ELECTRIC P8 Basic Training

Select the symbol libraries and click Open.

Press OK

EPLAN ELECTRIC P8 Basic Training

Now go to

Insert > Symbol

Press the button,

Press button,

EPLAN ELECTRIC P8 Basic Training

Type In the symbol libraries name and the description name, Click OK once you have finished.

EPLAN ELECTRIC P8 Basic Training

Now pressed the button in the value column.

Tick in the newly created symbol libraries. Press OK after you have completed

EPLAN ELECTRIC P8 Basic Training

Press OK

Here you go, your newly created symbol.

EPLAN ELECTRIC P8 Basic Training

4. Forms

Copying Existing Forms

Utilities > Master Data > Form > Copy.

EPLAN ELECTRIC P8 Basic Training

Select the type of form type.

EPLAN ELECTRIC P8 Basic Training

Select the form you want to copy and click Open.

Create a name for your form.

EPLAN ELECTRIC P8 Basic Training

If you want to modified the text properties;

Insert > Special text > Project properties or Page properties.

Choose what information you want to displayed by pressing the button.

EPLAN ELECTRIC P8 Basic Training

Select the type of properties you want to displayed in the form, click OK after you have selected the properties

EPLAN ELECTRIC P8 Basic Training

Press OK

Click where you the properties text to be displayed when you generate the report on the future.

EPLAN ELECTRIC P8 Basic Training

Close the window after you have done with your modification.

Creating New Forms

Utilities > Master Data > Form > New

EPLAN ELECTRIC P8 Basic Training

Select the type of form you want to modified,

Create a new name for your form. Click save after you have done with your setting.

EPLAN ELECTRIC P8 Basic Training

Free Graphics Line Toolbar

Change the setting accordingly and click OK after you have done with your setting.

Use the free graphics line toolbar to design your form.

EPLAN ELECTRIC P8 Basic Training

To insert the text properties, go to

Insert > Special text > Project Properties / Page Properties

Click the to choose the properties you want to displayed when you generate the form.

EPLAN ELECTRIC P8 Basic Training

Select the properties you want to output and click OK

EPLAN ELECTRIC P8 Basic Training

Press OK

Place where you want to output in the form.

EPLAN ELECTRIC P8 Basic Training

Close the window after you have modified the form.

Defining Form Properties

Form type:

Select the desired form type from the drop-down list (such as "Terminal connection diagram", "Table of contents", "Order list", etc.). This property defines the type of form. Each form type is assigned a particular ID. This is used internally to generate the list of properties available (placeholder texts) that can be used during the editing of the form. Thus each form has a specific list of available fields. The form type ID is also used to generate the list of forms which are available in the "Reports" dialog for the generation of a particular document. For instance, if you want to generate a device tag list, only the forms present which are designated as device tag list forms are offered for selection.

Property name / Value list:

The available properties are displayed depending on the selected category. Some of them, for example "Company code" and "Modification date" have already been assigned values that can't be changed. Others, for example "Description" and

"Version", can be assigned values or their existing values can be changed.

The following properties are particularly important:

Name (form, plot frame): "Data" category, file name, write-protected Description (form, plot frame): "Data" category, string (multi-lingual) Plot frame to edit form: "Settings" category, string

Form handling: "Settings" category, drop-down list; specifies the form as a static or dynamic form.

Regenerate main sub-header: "Settings" category, special dialog

Number of columns / rows: "Settings" category, integer; maximum number of columns / rows generated on a page

EPLAN ELECTRIC P8 Basic Training

Form structure: "Settings" category, drop-down list; order in which rows and columns are filled in. The process always starts in the upper left. "By row"

means that first all cells of a row are filled in before switching to the next row.

In this case, bridges are displayed vertically. "By column" means that first all cells of a column are filled in before switching to the next column. In this case, bridges are displayed horizontally.

Dynamic row adjustment: "Settings" category, check box. If indirect properties are indexed with 0, then the values for all (meaningful) indices are printed together. This is generally done using one-row lists separated by semicolons.

In forms, however, you have the option of printing these values as independent elements (rows / columns).

Example: Indirect goal.Name(0) gives M1;M2;X1:2. If dynamic row

adjustment is activated, then these four target names are printed one under the other.

Jumpers: Height of first level: "Settings" category, decimal (in "mm"); height of a jumper in the first level in the terminal diagram. The distance to the next jumper is defined by the property "Jumpers: Spacing".

Jumpers: Distance: "Settings" category, decimal (in "mm"); distance between two jumpers in neighboring levels. (The height of the first jumper is defined by the property "Jumpers: Height of first level".)

Jumpers: Radius of connecting points: "Settings" category, decimal (in "mm");

since the nodes of jumpers are graphically shown in the terminal diagram with a small filled circle, you specify the radius of this circle with this property (in software coordinates). (Start and end "legs" don't have dots.)

Jumpers: Radius for nodes: "Settings" category, decimal (in "mm"); if jumpers are shown graphically in the terminal diagram, then a small filled circle is set on the base line on each "leg" of the jumper. The radius of this circle is specified with this property (in software coordinates).

Jumpers: Height of external wire jumper: "Settings" category, decimal (in

"mm"); height of an internal / external jumper in the first level in the terminal diagram. If the matching property is not set, this is used instead of "Jumpers:

height of first level".

Jumpers: Height of internal / external wire jumper: "Settings" category, decimal (in "mm"); distance between two internal / external wire jumpers in neighboring levels. If the property is not set, "Jumpers: distance" is used.

Format for automatic page description: "Settings" category, special dialog;

format for the page description automatically assigned when generating report lists.

Assignment 'Index to graphic': "Settings" category, special dialog;

configuration property which assigns each graphic an index value; the

selection of graphics is this done in the "Fixed graphic" placeholder by giving the index value.

Assignment: Function definition to graphic: "Settings" category, special dialog;

assignment of a terminal type number to a symbol variant. Used when generating a page in order to create a fixed symbol graphic.

EPLAN ELECTRIC P8 Basic Training

Connection diagram: Suppress jumper targets: "Settings" category, integer;

determines what type of jumper targets is not to be displayed in connection point diagrams:

0 = Show all jumper targets

1 = Hide saddle jumper targets, show wire jumper targets 2 = Suppress saddle and wire jumper targets.

Connection diagram: Number of graphical levels (internal / external):

Category "Settings", Integer

Connection diagram: New row in the case of graphical overlapping: "Settings"

category, check box; if this property is set, then in case of overlapping of graphical views in connection diagrams, a new row is started or an empty row inserted. An overlap occurs when one of the relevant graphics layers does not contain the same device as the next record on the same level. More compact views can be implemented in connection diagrams in this way. The properties

"Connection diagram: Number of graphical levels (internal) / (external)" must be set correctly.

Structure identifier overview: "Settings" category, drop-down list for selection of structure identifiers to be displayed in the form.

Combine multi-level terminals: "Settings" category, check box; useful for terminal line-up diagrams.

Assignment of property / value to graphic: "Settings" category, special dialog;

assignment of a property and / or value to a symbol variant.

Jumper display: "Settings "category, drop-down list (line, angle) Jumpers: Line thickness: "Settings" category, decimal (in "mm") Jumpers: Number of levels: Category "Settings", Integer

Number of cables...: Category "Settings", integer

Cable distance...: "Settings" category, decimal (in "mm") Horizontal symbol distance: "Settings" category, decimal

Number of adjacent symbols: "Settings" category, integer "1-X"

Grid: "Settings " category, string (default: 4 mm) Modification date (manual): "Revision" category, date Version: "Revision" category, string

Company code: "Data" category, string, write-protected

EPLAN ELECTRIC P8 Basic Training

Dynamic Forms

Form in which the graphics can be changed (e.g., the number of lines: only those are displayed which have data filled in, no empty ones), that is, the graphics are adapted to the actual number of lines. In this kind of form, header, data, and footers can also be determined within one page.

Check the form to be modified

EPLAN ELECTRIC P8 Basic Training

Copy and paste in the same place, then rename to another form name, eg F04.f03

EPLAN ELECTRIC P8 Basic Training

Highlight the unwanted table, delete it.

Click on the page, Open the page properties,(shift + D) Go to properties and change the setting as follows:

1) Columns change to : 1 ( 1 column)

2) Horizontal symbols : 25 (cross-ref space) 3) Number of adjacent : 20 (component in a row) 4) Form handling : Dynamic (auto lines)

EPLAN ELECTRIC P8 Basic Training

Go to form and edit the properties of the forms

Change the form accordingly .

EPLAN ELECTRIC P8 Basic Training

EPLAN ELECTRIC P8 Basic Training

Draw a normal lines

From the Data area, Click the area that require repeated.

EPLAN ELECTRIC P8 Basic Training

Then close and proceed as below.

EPLAN ELECTRIC P8 Basic Training