Parapet Detail - Boundary Wall Gutter 67

Eaves Details - External Gutter 68

Verge Details - Wall Cladding 69

External Corner Detail 70

Pre-formed External Corner Detail 70

Vertical Joint Details 71

Window Head and Cill Detail 72

Window Jamb Detail 72

Personnel Door Detail - (Door head panel site cut) 73

Door Jamb & Door Head Detail 73

Drip Detail - Above Floor Level & Below Floor Level 74

Up and Over Door Head Detail 75

Door Jamb Detail 75

Internal ridge flashing with 150mm overlap sealed with air seal, Vapourflex or gun-grade sealant

Purlin

Air seal - 8mm Ø butyl rubber sealant

RIDGE DETAIL

KS1000 RW/LPCB insulated roof panel Profiled filler sealed top and

bottom with gun-grade sealant Ridge flashing with 150mm sealed butt straps

Profiled filler set back 80 to 100mm to prevent bird attack Site applied Alfasbond fire rated (FR) canister insulation

Building Regulations Part L2 Thermal Data fmin= 0.97

Y

= 0.004 W/mK

The above values are only applicable to the components on this detail.

Changes to the components will have an effect on the given values.

Double sided Plastisol

“Highline”

type gutter

Eaves beam

Site applied Alfasbond fire rated (FR) canister insulation

20 mm

35 mm

20 mm

Gutter support 0.7mm thick doubled sided plastisol coated

75mm Approx

200mm fixing centres

200mm fixing centres

EAVES DETAIL - EXTERNAL GUTTER

9mm x 3mm butyl rubber sealant Air seal - 8mm Ø butyl rubber sealant Air seal - 6mm Ø butyl rubber sealant

*

Building Regulations Part L2 Thermal Data fmin= 0.92

Y

= 0.27 W/mK

The above values are only applicable to the components on this detail.

Changes to the components will have an effect on the given values.

*

Air seal - Vapourflex sealant is to be applied over any breaks in supporting secondary steelwork to give a continuous bearing face.

PARAPET DETAIL - BOUNDARY WALL GUTTER

35mm Min 60mm

Parapet flashing with 150mm sealed butt straps

Air seal - 6mm Ø butyl rubber sealant

Parapet rail with air seal, Vapourflex tape to rail joints Site applied PIR board insulation

Profiled filler sealed top and bottom with gun-grade sealant

Sheeting rail Air seal - 6mm Ø butyl rubber sealant Site applied Alfasbond fire rated (FR) canister insulation

Purlin

Gutter outlet Eaves beam gutter support Site applied Alfasbond fire rated (FR) canister insulation

Building Regulations Part L2 Thermal Data 0.25 W/m2K gutter fmin= 0.90

Y

= 0.13 W/mK 0.35 W/m2K gutter fmin= 0.90

Y

= 0.21 W/mK

0.35 sole width 300mm and depth 150mm, values for other widths available on request. The above values are only applicable to the components on this detail. Changes to the components will have an effect on the given values.

KS1000 RW/LPCB insulated roof panel

Air seal - 8mm Ø butyl rubber sealant Factory made thermally broken membrane lined gutter with PIR board insulation to 0.25 or 0.35 W/m2K U-value KS1000 RW/

LPCB wall panel vertically laid Profiled filler sealed top and bottom with gun-grade sealant

Purlin Air seal - 8mm Ø butyl rubber sealant Gutter outlet offset to miss

stanchion head tie Air seal - 8mm

Ø butyl rubber sealant

KS1000 RW/LPCB insulated roof panel

VALLEY GUTTER DETAIL

Building Regulations Part L2 Thermal Data 0.25 W/m2K gutter fmin= 0.94

Y

= 0.27 W/mK 0.35 W/m2K gutter fmin= 0.93

Y

= 0.43 W/mK

0.35 sole width 600mm and depth 150mm, values for other widths available on request. The above values are only applicable to the components on this detail. Changes to the components will have an effect on the given values.

Stanchion head tie if necessary as steelwork design

Factory made thermally broken membrane lined gutter with PIR board insulation to 0.25 or 0.35 W/m2K U-value

Air seal - 6mm Ø butyl rubber sealant Profiled filler sealed top and bottom with gun-grade sealant Purlin Verge flashing with 150mm sealed butt straps

Cleader angle by steel sub-contractor with air seal - Vapourflex sealant applied at joints Air seal - 8mm Ø butyl rubber sealant Verge zed support with 150mm sealed overlaps 9mm x 3mm butyl rubber sealant

Direction of Lay

VERGE DETAIL - WALL CLADDING (END OF ROOF SHEETING)

PIR board insulation with site applied Alfasbond fire rated (FR) canister insulation to fill any gaps if required to maintain continuity of insulation

Building Regulations Part L2 Thermal Data fmin= 0.96

Y

= 0.01 W/mK

The above values are only applicable to the components on this detail.

Changes to the components will have an effect on the given values.

HIP DETAIL

Panels site cut to suit rake angle

Purlin Hip rafter

Internal ridge flashing with 150mm overlap sealed with Vapourflex or gun-grade sealant

KS1000 RW/LPCB insulated roof panel

Air seal - 8mm Ø butyl rubber sealant Site applied Alfasbond fire rated (FR) canister insulation

Profiled filler set back 80 to 100mm to prevent bird attack Cleader angle by steel

sub-contractor Hip flashing with 150mm sealed butt straps

Rake cut profiled filler sealed top and bottom with gun-grade sealant

Building Regulations Part L2 Thermal Data fmin= 0.97

Y

= 0.004 W/mK

The above values are only applicable to the components on this detail.

Changes to the components will have an effect on the given values.

VALLEY HIP DETAIL

Double sided Plastisol coated flashing

Air seal - 8mm Ø butyl rubber sealant

Purlin Hip rafter

KS1000 RW/LPCB insulated roof panel

Edge protection lacquer applied to all panels cut on site to suit rake angle Cleader angle by steel

sub-contractor

Building Regulations Part L2 Thermal Data fmin= 0.94

Y

= 0.29 W/mK

The above values are only applicable to the components on this detail.

Changes to the components will have an effect on the given values.

Air seal - 8mm Ø butyl rubber sealant

Factory made thermally broken membrane lined gutter with PIR board insulation to 0.25 or 0.35 W/m2K U-value

Outer sheet turned up with roof slopes below 4˚

Profiled filler sealed top and bottom with gun-grade sealant KS1000 LP/LPCB insulated roof panel

Air seal - 8mm Ø butyl rubber sealant

Purlin Profiled filler set back 80 to

100mm to prevent bird attack

Apex dam (Ref: LP1) Cover cap

RIDGE DETAIL

2 No. runs silicone sealant

20mm x 3mm butyl rubber sealant Site applied Alfasbond fire rated (FR) canister insulation

Internal ridge flashing with 150mm overlap sealed with Vapourflex or gun-grade sealant

Building Regulations Part L2 Thermal Data fmin= 0.97

Y

= 0.004 W/mK

The above values are only applicable to the components on this detail.

Changes to the components will have an effect on the given values.

Ridge flashing with 150mm sealed butt straps

PARAPET DETAIL - BOUNDARY WALL GUTTER

75mm

35mm Min 60mm

Parapet flashing with 150mm sealed butt straps

Air seal - 6mm Ø butyl rubber sealant

Parapet rail with air seal Vapourflex tape to rail joints

Site applied PIR board insulation

Profiled filler sealed top and bottom with gun-grade sealant

Profiled filler sealed top and bottom with gun-grade sealant

Sheeting rail Air seal - 6mm Ø butyl rubber sealant Site applied Alfasbond fire rated (FR) canister insulation

Purlin

Gutter outlet

Eaves beam gutter support Site applied Alfasbond fire rated (FR) canister insulation

KS1000 LP/LPCB insulated roof panel

Factory made thermally broken membrane lined gutter with PIR board insulation to 0.25 or 0.35 W/m2K U-value KS1000 RW/

LPCB wall panel vertically laid

Profiled filler sealed top and bottom with gun-grade Top sheet turned down on site with roof pitches below 4˚

Building Regulations Part L2 Thermal Data 0.25 W/m2K gutter fmin= 0.90

Y = 0.13

0.35 W/m2K gutter fmin= 0.90

Y = 0.21

0.35 sole width 300mm and depth 150mm, values for other widths available on request. The above values are only applicable to the components on this detail. Changes to the components will have an effect on the given values.

Air seal - 8mm Ø butyl rubber sealant

PARAPET DETAIL - BOUNDARY WALL GUTTER

75mm

35mm Min 60mm

Parapet flashing with 150mm sealed butt straps

Air seal - 6mm Ø butyl rubber sealant Parapet rail with air seal - Vapourflex tape to rail joints Site applied PIR board insulation

Air seal - 6mm Ø bead of gun-grade sealant Profiled filler sealed top and bottom with gun-grade sealant

Sheeting rail Air seal - 6mm Ø butyl rubber sealant Site applied Alfasbond fire rated (FR) canister insulation

Purlin

Gutter outlet

Eaves beam gutter support Site applied Alfasbond fire rated (FR) canister insulation

KS1000 LP/LPCB insulated roof panel

KS1000 RW/

LPCB wall panel vertically laid KS1000 MR/

LPCB wall panel horizontally laid 4mm Ø butyl rubber sealant

Gun-grade seal at panel joints inline with 8mm butyl Top sheet turned down on site with roof pitches below 4˚

Building Regulations Part L2 Thermal Data 0.25 W/m2K gutter fmin= 0.90

Y

= 0.13 W/mK 0.35 W/m2K gutter fmin= 0.90

Y

= 0.21 W/mK

0.35 sole width 300mm and depth 150mm, values for other widths available on request. The above values are only applicable to the components on this detail. Changes to the components will have an effect on the given values.

Direction of Lay

Air seal - 8mm Ø butyl rubber sealant Factory made thermally broken membrane lined gutter with PIR board insulation to 0.25 or 0.35 W/m2K U-value

Air seal - 8mm Ø butyl rubber sealant Air seal - 6mm Ø butyl rubber sealant Site applied Alfasbond fire rated (FR) canister insulation Top sheet turned down on site with roof pitches below 4˚

9mm x 3mm butyl rubber sealant

20

KS1000 RW/LPCB wall panel vertically laid

75mm

200mm fixing centres

200mm fixing centres

EAVES DETAIL - EXTERNAL GUTTER

Gutter support 0.7mm thick double sided plastisol coated

Double sided plastisol Highline type gutter

Gun-grade seal at panel joints inline with 8mm butyl KS1000 LP/LPCB insulated roof panel Stitching screw fixings for gutter brackets

Building Regulations Part L2 Thermal Data fmin= 0.92

Y

= 0.27 W/mK

The above values are only applicable to the components on this detail.

Changes to the components will have an effect on the given values.

*

*

Air seal - Vapourflex sealant is to be applied over any breaks in supporting secondary steelwork to give a continuous bearing face.

Air seal - 8mm Ø butyl rubber sealant Air seal - 6mm Ø bead of gun-grade sealant Site applied Alfasbond fire rated (FR) canister insulation Top sheet turned down on site with roof pitches below 4˚

9mm x 3mm butyl rubber sealant

20

KS1000 MR/LPCB wall panel horizontally laid

75mm Approx

200mm fixing centres

200mm fixing centres

EAVES DETAIL - EXTERNAL GUTTER

Gutter support 0.7mm thick double sided plastisol coated

Double sided plastisol Highline type gutter

Gun-grade seal at panel joints inline with 8mm butyl KS1000 LP/LPCB insulated roof panel Stitching screw fixings for gutter brackets

Building Regulations Part L2 Thermal Data fmin= 0.95

Y

= 0.13 W/mK

The above values are only applicable to the components on this detail.

Changes to the components will have an effect on the given values.

*

Air seal - Vapourflex sealant is to be applied over any breaks in supporting secondary steelwork to give a continuous bearing face.

*

75mm Cover cap

VALLEY GUTTER DETAIL

Purlin Gun-grade seal at panel joints inline with 8mm butyl

Gutter outlet offset to miss stanchion head tie Air seal - 8mm

Ø butyl rubber sealant Stanchion head tie if necessary as steelwork design

Air seal - 8mm Ø butyl rubber sealant

Building Regulations Part L2 Thermal Data 0.25 W/m2K gutter fmin= 0.96

Y

= 0.13 W/mK 0.35 W/m2K gutter fmin= 0.96

Y

= 0.25 W/mK

0.35 sole width 600mm and depth 150mm, values for other widths available on request. The above values are only applicable to the components on this detail. Changes to the components will have an effect on the given values.

Top sheet turned down on site with roof pitches below 4˚

Factory made thermally broken membrane lined gutter with PIR board insulation to 0.25 or 0.35 W/m2K U-value

VERGE DETAIL - WALL CLADDING (START OF ROOF SHEETING)

Direction of Lay

Verge flashing with 150mm sealed butt straps

20mm x 3mm butyl rubber sealant

Purlin Air seal - 8mm Ø butyl rubber sealant Air seal - 6mm Ø butyl rubber sealant Gable rafter

4mm Ø butyl rubber sealant PIR board insulation with site applied Alfasbond fire rated (FR) canister insulation to fill any gaps if required to maintain continuity of insulation

Cleader angle by steel sub-contractor with air seal Vapourflex sealant applied at joints KS1000 LP/LPCB insulated roof panel

KS1000 RW/LPCB insulated wall panel horizontally laid Building Regulations Part L2 Thermal Data

fmin= 0.96

Y

= 0.01 W/mK

The above values are only applicable to the components on this detail.

Changes to the components will have an effect on the given values.

VERGE DETAIL - WALL CLADDING (START OF ROOF SHEETING)

Direction of Lay

Verge flashing with 150mm sealed butt straps

20mm x 3mm butyl rubber sealant

Purlin Air seal - 8mm Ø butyl rubber sealant Air seal - 6mm Ø bead of gun-grade sealant Gable rafter

4mm Ø butyl rubber sealant PIR board insulation with site applied Alfasbond fire rated (FR) canister insulation to fill any gaps if required to maintain continuity of insulation

Cleader angle by steel sub-contractor with air seal Vapourflex sealant applied at joints KS1000 LP/LPCB insulated roof panel

KS1000 MR/LPCB insulated wall panel horizontally laid Building Regulations Part L2 Thermal Data

fmin= 0.96

Y

= 0.01 W/mK

The above values are only applicable to the components on this detail.

Changes to the components will have an effect on the given values.

VERGE DETAIL - WALL CLADDING (END OF ROOF SHEETING)

Direction of Lay Verge flashing with 150mm sealed butt straps

20mm x 3mm butyl rubber sealant

Purlin

Air seal - 8mm Ø butyl rubber sealant Air seal - 6mm Ø butyl rubber sealant Gable rafter

Profiled filler sealed top and bottom with gun-grade sealant

PIR board insulation with site applied Alfasbond fire rated (FR) canister insulation to fill any gaps if required to maintain continuity of insulation

Cleader angle by steel sub-contractor with air seal Vapourflex sealant applied at joints

KS1000 LP/LPCB insulated roof panel

KS1000 RW/LPCB insulated

wall panel vertically laid Building Regulations Part L2 Thermal Data

fmin= 0.96

Y

= 0.01 W/mK

The above values are only applicable to the components on this detail.

Changes to the components will have an effect on the given values.

VERGE DETAIL - WALL CLADDING (END OF ROOF SHEETING)

Direction of Lay Verge flashing with 150mm sealed butt straps

20mm x 3mm butyl rubber sealant

Purlin

Air seal - 8mm Ø butyl rubber sealant Air seal - 6mm Ø bead of gun-grade sealant Gable rafter

4mm Ø butyl rubber sealant

PIR board insulation with site applied Alfasbond fire rated (FR) canister insulation to fill any gaps if required to maintain continuity of insulation

Cleader angle by steel sub-contractor with air seal Vapourflex sealant applied at joints KS1000 LP/LPCB insulated roof panel

KS1000 MR/LPCB insulated wall panel horizontally laid

Building Regulations Part L2 Thermal Data fmin= 0.96

Y

= 0.01 W/mK

The above values are only applicable to the components on this detail.

Changes to the components will have an effect on the given values.

Cleader angle by steelwork contractors Air seal - 8mm Ø butyl rubber sealant Edge protection lacquer applied to all panels cut on site to suit rake angle

Purlin Hip rafter

VALLEY HIP DETAIL

Cover cap KS1000 LP/LPCB insulated roof panel

Double sided plastisol coated flashing Gun-grade seal at panel joints inline with 8mm butyl

Factory made thermally broken membrane lined gutter with PIR board insulation to 0.25 or 0.35 W/m2K U-value

Building Regulations Part L2 Thermal Data fmin= 0.94

Y

= 0.29 W/mK

The above values are only applicable to the components on this detail.

Changes to the components will have an effect on the given values.

HIP DETAIL

20mm x 3mm butyl rubber sealant Cover cap

2 No. runs of silicone sealant Panels site cut to suit rake angle

Apex dam (Ref: LP1/A)

Purlin

Hip rafter Internal ridge flashing with 150mm overlap

sealed with Vapourflex or gun-grade sealant

Cleader angle by steelwork contractor Outer sheet turned up on site with roof pitches below 4˚

Hip flashing with 150mm sealed butt straps

Rake cut profiled filler sealed top and bottom with gun-grade sealant KS1000 LP/LPCB

insulated roof panel

Site applied Alfasbond fire rated (FR) canister insulation

Building Regulations Part L2 Thermal Data fmin= 0.97

Y

= 0.004 W/mK

The above values are only applicable to the components on this detail.

Changes to the components will have an effect on the given values.

Air seal - 8mm Ø butyl rubber sealant

Building Regulations Part L2 Thermal Data fmin= 0.64

Y

= 0.54 W/mK

The appropriate Y value for the brickwork, blocks or concrete must be added to the above Y value to obtain the total loss through this junction detail.

The above values are only applicable to the components on this detail.

Changes to the components will have an effect on the given values.

100mm min.

lap over wall 35mm

min

Air seal - 6mm Ø butyl rubber sealant

DRIP DETAIL

Sheeting rail Stanchion

PIR board insulation with Alfasbond (FR) canister applied insulation to fill any gaps if required to maintain continuity of insulation

Panels specified with flush ends will have a minimum cut back of 10mm

Optional internal closure flashing to mask insulation from view

Drip flashing Air seal - continuous bead of gun-grade sealant

Building Regulations Part L2 Thermal Data fmin= 0.95

Y

= 0.01 W/mK

The above values are only applicable to the components on this detail.

Changes to the components will have an effect on the given values.

EXTERNAL CORNER DETAIL

Corner column

Sheeting rail

Internal cleader angle by steel sub-contractor with air seal Vapourflex sealant applied at joints Zed support lapped 100mm at joints Air seal - 6mm Ø butyl rubber sealant

External corner flashing with 100mm sealed overlaps

On site remove overlap leg from panel

KS1000 RW/LPCB insulated wall panel vertically laid

KS1000 RW/LPCB insulated wall panel vertically laid

9mm x 3mm butyl rubber sealant Direction of Lay

PIR board insulation with site applied air seal Alfasbond fire rated (FR) canister insulation to fill any gaps if required to maintain continuity of insulation Site cut vertical sheeting

Profiled filler sealed top and bottom with gun-grade sealant

Optional internal head flashing

Window support rail

Ferrules used to fix windows Air seal - 6mm Ø butyl rubber sealant Air seal - 6mm Ø butyl rubber sealant

PIR board insulation

External soffit flashing with no connection to internal flashing

Polyethylene backing rod with silicone sealant by window installer

Site applied Alfasbond fire rated (FR) canister insulation Head flashing

Window depth to suit panel module

Window unit by others 25mm thick PIR board insulation 9mm x 3mm butyl rubber sealant

Window cill flashing with 3° slope to facilitate drainage (no connection to internal flashing)

WINDOW HEAD AND CILL DETAIL

Internal head flashing (optional) with no connection to external soffit flashing Building Regulations Part L2 Thermal Data

fmin= 0.50

Y

= 0.61 W/mK

The appropriate Y value for the window system must be added to the above Y value to obtain the total heat loss through this junction detail.

The above values are only applicable to the components on this detail.

Changes to the components will have an effect on the given values.

Building Regulations Part L2 Thermal Data fmin= 0.95

Y

= 0.07 W/mK

The appropriate Y value for the window system must be added to the above Y value to obtain the total heat loss through this junction detail.

The above values are only applicable to the components on this detail.

Changes to the components will have an effect on the given values.

Internal jamb flashing with no connection to external flashing

Window width

Jamb steelwork 25mm thick PIR board insulation

Window unit by others

9mm x 3mm butyl rubber sealant

WINDOW JAMB DETAIL OPTION 1 WINDOW JAMB DETAIL OPTION 2

Site cut panel External jamb flashing with no connection to internal flashing Air seal - 6mm Ø butyl rubber sealant Polyethylene backing rod with silicone sealant

Building Regulations Part L2 Thermal Data fmin= 0.96

Y

= 0.08 W/mK

The appropriate Y value for the window system must be added to the above Y value to obtain the total heat loss through this junction detail.

The appropriate Y value for the window system must be added to the above Y value to obtain the total heat loss through this junction detail.

In document PRIMERA PARTE (página 176-199)