DTDTr1,96EE
Estrato 3: Fumadores
X. ESTUDIOS EXPERIMENTALES
4. ENSAYO CLINICO
4.1. Diseño
■
■
A device is specified in the system by three identifiers. However, not all devices have three device IDs. For devices that have only one or two device identifiers, zeros must be entered for the remaining device identifier parameters as place holders.
Device ID requirements
Table 3-3lists and defines the device ID requirements.
Table 3-3 Device ID requirements Device
Names/IDs Range Definition
ABSS Associated Base Station Processor
device ID 1 0 - 254 Corresponds to the BSS network entity that this device represents.
device ID 2 0 Serves as place holder.
device ID 3 0 Serves as place holder.
AXCDR Associated XCDR
device ID 1 0 - 254 Corresponds to the RXCDR network entity that this device represents.
device ID 2 0 Serves as place holder.
device ID 3 0 Serves as place holder.
BCUP BSS Controller Unit Power Supply per cage.
device ID 1 0 - 15 Identifies the cage number.
device ID 2 0 - 2 Identifies which power supply (of the three possible per cage).
device ID 3 0 Serves as place holder.
BSP Base Site Processor, BSC
device ID 1 0 or 1 Identifies which BSP board is active and which is redundant (standby). (None at a BTS.)
device ID 2 0 Serves as place holder.
device ID 3 0 Serves as place holder.
BSS Base Station System
device ID 1 0 - 254 Identifies BSS.
device ID 2 0 Serves as place holder.
device ID 3 0 Serves as place holder.
BTP Base Transceiver Processor, BTS
Continued
Device ID requirements Chapter 3: Device/function related commands
Table 3-3 Device ID requirements (Continued) Device
Names/IDs Range Definition
device ID 1 1 Identifies which BTP board is active and which is redundant (standby). (None at a BSC or RXCDR.)
device ID 2 0 Serves as place holder.
device ID 3 0 Serves as place holder.
CAB CABinet
device ID 1 0 - 20 Identifies cabinet number.
device ID 2 0 Serves as place holder.
device ID 3 0 Serves as place holder.
CAGE CAGE
device ID 1 0 - 15 Identifies the value at which the LANX card, dial is set.
device ID 2 0 Serves as place holder.
device ID 3 0 Serves as place holder.
CBL Cell Broadcast Link
device ID 1 0 Optional entry. (None at a BTS or RXCDR.) device ID 2 0 Serves as place holder.
device ID 3 0 Serves as place holder.
CBUS Clock BUS
device ID 1 0 - 15 Identifies the cage where a specific GCLK is located.
device ID 2 0 or 1 Identifies the GCLK.
device ID 3 0 Serves as place holder.
COMB COMBiner
device ID 1 0 - 13 Identifies specific combiner cavities (13 active, 13 standby).
(None at an RXCDR.)
device ID 2 0 or 1 Identifies each individual processor in a combiner unit (of the two present within a redundant pair).
device ID 3 0 Serves as place holder.
CSFP Code Storage Facility Processor
device ID 1 10 CSFP identifier (only at a BSC) - not M-Cell, automatically equipped/unequipped.
device ID 2 0 Serves as place holder.
device ID 3 0 Serves as place holder.
DHP Digital radio Host Processor, BTS
device ID 1 0 - 5 Identifies a digital module shelf (cage number) in a specific cabinet. (None at an RXCDR.)
Technical Description: BSS Command Reference Device ID requirements
Table 3-3 Device ID requirements (Continued) Device
Names/IDs Range Definition
device ID 2 0 - 7 Identifies which DHP board is active and which is redundant (standby).
device ID 3 0 Serves as place holder.
DPROC Digital Processor (GPRS)
device ID 1 1 - 6 or 11 - 16
Identifies a specific DPROC Board.
device ID 2 0 Serves as place holder.
device ID 3 0 Serves as place holder.
DRI Digital Radio Interface
device ID 1 0 - 5 Identifies a user-defined DRI group within a site. The DRIs which belong to this group must be allocated to the same cell and must be connected to the same antenna. (None at an RXCDR.)
device ID 2 0 - 11 Identifies a specific DRI board.
device ID 3 0 Serves as place holder.
EAS External Alarm System
device ID 1 0 - 7 0 - 15
Identifies a specific PIX card at a site - not M-Cell.
M-Cell
device ID 2 0 Serves as place holder.
device ID 3 0 Serves as place holder.
GBL Gb Link (GPRS)
device ID 1 0 - 35 Identifies a specific GBL link device ID 2 0 Serves as place holder device ID 3 0 Serves as place holder
GCLK General CLocK
device ID 1 0 or 1
0
Identifies which GCLK board is active and which is redundant (standby).
0=A side GCLK (slot A controls) - slot 5 1=B side GCLK (slot B controls) - slot 3 M-cell, automatically equipped/unequipped.
device ID 2 0 Serves as place holder.
device ID 3 0 Serves as place holder.
GDS GPRS Data Stream (GPRS)
device ID 1 0 - 37 Identifies a specific GPRS data stream.
device ID 2 0 Serves as place holder.
device ID 3 0 Serves as place holder.
GPROC Generic PROCessor, device used for functions.
Continued
Device ID requirements Chapter 3: Device/function related commands
Table 3-3 Device ID requirements (Continued) Device
Names/IDs Range Definition
device ID 1 0 - 111 Identifies a specific GPROC board.
device ID 2 0 Serves as place holder.
device ID 3 0 Serves as place holder.
GSL GPRS Signaling Link (GPRS)
device ID 1 0 - 59 Identifies a specific GPRS signaling link.
device ID 2 0 Serves as place holder.
device ID 3 0 Serves as place holder.
KSW Kiloport SWitch
device ID 1 0 - 3 Identifies a section (timeslot) of TDM highway.
M-Cell not applicable.
device ID 2 0 or 1 Identifies which KSW board (highway, A side, or B side) is active and which is redundant (standby). (0 is slot 27 and 1 is slot 1.) device ID 3 0 Serves as place holder.
LAN Local Area Network
device ID 1 0 or 1 Identifies which LAN board (A side or B side) is active and which is redundant (standby).
device ID 2 0 Serves as place holder.
device ID 3 0 Serves as place holder.
MMS The E1 Mbit/s line on a Multiple Serial Interface board.
device ID 1 {22169}
Matches the first ID of the host MSI with 0 - 95 for BSC and 0 - 123 for RXCDR.
BTS only: not M-Cell BTS only: M-Cell6 BTS only: M-Cell2 BTS only: M-Cellmicro device ID 2 0 or 1 Identifies a specific MMS.
device ID 3 0 Serves as place holder.
MSI Multiple Serial Interface board
device ID 2 0 Serves as place holder.
device ID 3 0 Serves as place holder.
Technical Description: BSS Command Reference Device ID requirements
Table 3-3 Device ID requirements (Continued) Device
Names/IDs Range Definition
device ID 1 0 - 15 Identifies a specific MTP link (per ITU-TSS spec).
device ID 2 0 Serves as place holder.
device ID 3 0 Serves as place holder.
OML Operations and Maintenance Link
device ID 1 0 - 3 Identifies a specific connection (link) between the BSC and the OMC-R (BSC or RXCDR).
device ID 2 0 Serves as place holder.
device ID 3 0 Serves as place holder.
OPL OPtimization Link
device ID 1 0 - 3 Identifies a specific connection (link) between the BSC and the IOS platform.
device ID 2 0 Serves as place holder.
device ID 3 0 Serves as place holder.
PATH
device ID 1 0 - 140 Identifies the terminating site (BSC only).
device ID 2 0 - 9 Identifies a unique PATH ID.
device ID 3 0 Serves as place holder.
PBUS Processor (MCAP) BUS
device ID 1 0 - 15 Identifies the cage at that location.
device ID 2 0 or 1 Identifies which PBUS (A side or B side) is active and which is redundant (standby).
device ID 3 0 Serves as place holder.
RSL Radio System Link
device ID 1 0 - 140 Identifies the site to which the RSL is connecting (BSC only).
device ID 2 0 - 7 5 1
Identifies a specific link set (not M-Cell):
M-Cell2and M-Cell6 M-Cellmicro
device ID 3 0 Serves as place holder.
RTF Receive Transmit Function
device ID 1 0 - 5 Identifies the cell group.
device ID 2 0 - 11 Identifies a unique function within the cell group.
device ID 3 0 Serves as place holder.
RXCDR Remote transcoder
device ID 1 0 - 254
device ID 2 0 Serves as place holder.
Continued
Device ID requirements Chapter 3: Device/function related commands
Table 3-3 Device ID requirements (Continued) Device
Names/IDs Range Definition
device ID 3 0 Serves as place holder.
SITE BTS SITE
device ID 1 0 - 140 Identifies the site for which commands are being executed.
device ID 2 0 Serves as place holder.
device ID 3 0 Serves as place holder.
SBUS Serial BUS
device ID 1 0 - 15 Identifies the cage at that location.
device ID 2 0 or 1 Identifies which SBUS (A side or B side) is active and which is redundant (standby).
device ID 3 0 Serves as place holder.
TBUS TDM BUS
device ID 1 0 - 15 Identifies the cage at that location.
device ID 2 0 or 1 Identifies which TBUS (A side or B side) is active and which is redundant (standby).
TDM Time Division Multiplex Highway
device ID 1 0 or 1 Identifies which side (A side or B side) of the TDM highway is active and which is redundant (standby).
device ID 2 0 Serves as place holder.
device ID 3 0 Serves as place holder.
XBL RXCDR to BSC Fault Management Link.
device ID 1 0 - 9 Identifies a specific connection (link) between the RXCDR and the BSC.
device ID 2 0 Serves as place holder.
device ID 3 0 Serves as place holder.
Technical Description: BSS Command Reference Function related commands