CONTRIBUCIONES A LA ECONOMÍA DEL EMPRENDIMIENTO
8. EL MODELO DE DECISIÓN OCUPACIONAL. CUATRO DIMENSIONES
WATER INDUSTRY BUILDINGSERVICES MINING
The Commerzbank headquarters in Frankfurt on the Main is the highest office building in Europe and dom- inates the skyline with its accom- plished architectural features. Impressive, too, is the number of KSB products integrated in the building’s various service systems that reliably fulfil their daily tasks
to their owner’s complete satisfac- tion: approximately 300 pumps and 2,000 valves of a wide variety of types and sizes have safeguarded safe and reliable fluid transport since 1997. Our extensive product scope, the know-how of our special- ists and KSB’s uncompromising quality management convinced the
customer to place his order with us. This is without doubt a reference we can be proud of.
For further information, contact us on phone number
+49 69 94208-221, by email at [email protected] or visit our website at www.ksb.com.
11
11
Dry running protection Selection criteria for PBUs
“Dry running protection” is the protection of the pumping station against inadmissible operation (such as lack of water) and the timely shutdown of the PBU to protect the supply network.
The following presents an overview of the various dry-running protection concepts.
11.1
Protection of the supply network
By stipulating minimum pressures, the General Water Supply Terms Ordinance (AVB Wasser V), the DIN 1988 and the future DIN EN 806 stand- ards endeavour to prevent consumers directly supplied via a house connection being inadmis- sibly compromised as a result of PBU operation. Possible causes for an inadmissible pressure drop at the house connection are for example:
• Insufficient supply network. The pressure of the mains water pipe drops when considerable quantities of water are extracted.
• If the service pipe’s diameter is insufficient, the supply pressure drops at the hand-over point when considerable quantities of water are con- sumed.
• Pressures drop at the hand-over point if consider- able quantities of water are pumped via the PBU (e. g. due to large pumps and/or a large mem- brane-type accumulator downstream of the PBU).
An inlet pressure monitoring device is installed on the PBU inlet side in order to monitor and observe the required minimum pressure of pmin,V= 1 bar. Depending on the unit, this monitoring equipment can either be a pressure switch or an analog pres- sure transmitter. Whenever the minimum pressure is reached the PBU should reduce the number of operating pumps.
Simultaneous stopping of all operating pumps must be avoided.
Alternatively, the possibility of an indirect connec- tion of the PBU providing sufficient protection should be examined.
11.2
Protection of pressure boosting unit High-pressure centrifugal pumps are mainly employed for PBUs and, apart from a few excep- tions, these are non-self priming pump types. This means that the inlet / suction pipe must be con- stantly filled with water.
In essence, all protection concepts aim to prevent inadmissible rises in temperature or, in the worst case, the dry running of the pumps.
A distinction should be made between direct and indirect protection methods.
Direct protection:
• Flow control on the PBU inlet side Indirect protection:
• Inlet pressure control upstream of the PBU – particularly in the case of cascade control (Hya-Eco and Hyamat K) – by making sure that the pumps can reach or exceed the cut- out pressure pco.
• Water level control in the inlet tank
• Pump performance monitoring (electrically) • Temperature monitors on each pump (alter-
natively)
Fig. 17:
Pressure development at the consumer end of the service pipe, i. e. upstream of the PBU, during start-up and shutdown of pumps
Permissible pressure
increase
Permissible pressure drop
Period of
operation Run-down time Pump start- up phase pmin,V 0.0 bar p2 p2 p1 p1 ≤ 1.0 bar 1.0 bar ≤ 0.5 pmin,V
Conclusion:
Generally, PBUs must be protected against operat- ing with a lack of water.
As a whole host of connection types for PBUs and different operating conditions exists, there is no such thing as a standard solution. The protection concept chosen must always suit the individual operating conditions (see Fig. 20).
Direct connection
PBU protection concepts
Options
Flow monitoring + pressure monitoring downstream of the PBU
Water level monitoring using a float switch
Pressure monitoring using a digital pressure transmitter 욷 0.5 bar
Water level monitoring using electrodes
Pressure monitoring using an analog pressure transmitter 욷 0.5 bar
Options Options PBU PBU PBU PBU PBU Q P P P e.g. BMS
PBU not self-priming
After “lack of water” tripping manual reset required
Indirect connection
Suction head operation Suction lift operation
Fig. 20:
12
Effects of inlet pressure fluctuations Supply pressure fluctuations at the hand-over point (water meter) influence the operating behaviour of pressure boosting units.
12.1
Indirect connection, Fig. 21
The PBU takes the required quantity of water from an unpressurized inlet tank situated up- stream.
The tank filling device is usually sized such that the PBU’s nominal flow rate QNis reached under normal inlet pressure (pinl) conditions. If the inlet pressure drops to the minimum inlet pressure pinl,minthis may lead to a significant reduction of the filling volume.
Example:
pinl,min = 1.0 bar pinl,max = 3.1 bar
pinl = 2 bar (angenommen) QN = 20 m3/h
Selection of float valve for pinl= 2 bar, Fig. 22 QN = 20 m3/h 씮 11⁄2”
at pinl,min= 1 bar 씮 Q = 14 m3/h
This results in a filling volume reduction of 30%. It should be noted that the stored volume will be used up under minimum inlet pressure conditions and a water consumption of more than 14 m3/h over a prolonged period of time (risking a lack-of- water condition).
The PBU’s function is not impaired as long as water is available.
12.2
Direct connection, Fig. 23 12.2.1
Inlet pressure fluctuations in the form of pressure increase
When PBUs with cascade control are used (Hya-Eco, Hyamat K, Hya-Solo D) inlet pressure fluctuations (in this case in the form of pressure increases) will directly influence the PBUs’ dis- charge pressure. Since cascade-controlled PBUs have an inherent discharge pressure fluctuation of ⌬p(co-ci)+ 0.3 bar (Fig. 24), the sum of discharge pressure fluctuation and inlet pressure fluctuation must be examined to ensure that it is acceptable for the consumers downstream. The maximum fluctuation range recommended by DIN 1988 is 2.5 bar. [31] PBU Fig. 21 Indirect connection 70 50 40 30 20 10 0 500 300 200 100 0 0 1 2 3 4 5 0 1 2 3 4 5 Q m /h3
Inlet pressure p bar Inlet pressure p bar Q m /h3 2 x 2” 2” DN 100 DN 80 1” 1 / ”1 2 14 Fig. 22
Selection diagram for filling devices
PBU
Fig. 21: Direct connection
12
Effects of inlet pressure fluctuations
Legend for [31]:
⌬pPBU,max = Maximum pressure difference
downstream of the PBU
⌬p(co-ci) = Switching pressure difference
⌬pinl,max = Maximum pressure upstream
of the PBU
If this is not the case, it is important to use an inlet side or discharge side pressure con- troller / reducer.
A negative effect of inlet pressure increase is the shifting of the minimum flow rate for continuous operation (Qcoat pco) and the minimum inlet pressure pinl,minto
considerably larger cut-out flow rates at increased inlet pressure, especially in the case of PBUs with a low number of stages.
The consequences are as follows (Fig. 24): • Low flow rates (> Qcofor pinl,min) lead to the
risk of excessive on/off operation (very high switching frequency of the PBU pumps). • As a result of the cut-out of the last pump in
operation at flow rates > Qcoaudible pressure surges in the pipes are to be expected.
Example:
Impact of inlet pressure increase on a real pump curve (Fig. 25), Hyamat K series.
Pump size: 0406
Qco = 1.5 m3/h at pinl,min
After an inlet pressure increase of 0.5 bar pinl= pinl,min+ 0.5 bar
the cut-out flow rate is Qco = 3 m3/h.
Cascade-controlled PBUs have fixed pressure- dependent switching points for pump cut-in and cut-out.
In the case of direct PBU connection, the respec- tive inlet pressure is added to the discharge head of the pump(s).
The factory-set value for the cut-out pressure pcois normally 0.3 bar lower than the maximum
discharge pressure of the pump (at Q = 0 m3/h). Point 1 on the pump curve (Fig. 25) characterizes the cut-out flow rate of the pump for the design inlet pressure pinl,min(not considering possible after-run time).
As a pump is always stopped whenever the cut-out pressure pcois exceeded, the conclusion in the case of increased inlet pressure is that the pump stops with a lower discharge pressure.
Point 2 demonstrates the increased cut-out flow rate at the lower pump discharge pressure. The characteristic curves used as an example clearly show that especially with flat pump curves (fewer stages) one can expect an excessive flow rate increase at the cut-out point.
Fig. 24:
The operating characteristics of a pressure boosting unit with cascade control, i. e. without speed control
Impact of inlet pressure increase of 0.3 bar
Discharge pressure
Pressure fluctuation inherent to PBU
p (co - ci) p (co - ci) + p inl,min + 0.3 bar p E p A H 0 Q co Q co Q D + 0.3 bar Example:
Pressure development of a system with 3 pumps with increasing flow rate (consumption) with decreasing flow rate (consumption)
12
Inlet pressure fluctuations in the form of pressure decrease
12.2.2
Inlet pressure fluctuations in the form of pressure decrease
Inlet pressure fluctuations (in this case in the form of pressure decreases) which fall below the min- imum inlet pressure are particularly dangerous for PBUs.
Cascade-controlled PBUs have a nominal cut-out pressure margin of 0.3 bar. This means that the maximum pump discharge head is 0.3 bar above the cut-out pressure pco. As soon as the minimum inlet pressure drops by more than 0.3 bar, the PBU
pumps in operation can no longer reach the cut- out pressure!
0 Pumps per system
1 Point 1 Point 2 3.0 2 4 6 8 10 12 2 3 4 5 6 / / 2 3 4 5 6 3 6 9 12 15 18 4 8 12 16 20 24 5 10 15 20 25 30 6 12 18 24 30 36 7 14 21 28 35 42 8 16 24 32 40 48 9 18 27 36 45 54 14.4 p bar A H m Q m /h3 160 150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0 0415 0413 0411 0409 0408 0407 0406 0405 0404 0403 0402 12.4 10.5 9.5 8.5 6.6 5.6 4.6 3.6 2.6 1.7 0 0.5 bar 7.5 0410 1.5 without stand- by pump with stand- by pump Characteristic curve valvues and tolerarances to ISO 2548, Annex B
Specifically selected PBU for p inl,min
Fig. 25:
13
Causes of pressure surges 13.1
Pressure surges caused by valves
All kinds of valves can, when they close quickly, lead to pressure surges.
The theoretic basis for calculating this phenom- enon is described in the formula by Joukowsky:
[32]
Legend for [32]
⌬H = Pressure increase
a = Propagation of a pressure wave at approx. 1000 - 1200 m/s
g = Acceleration due to gravity, approx. 10 m/s2
⌬v = Velocity difference
The full impact of the pressure surge can be math- ematically expressed by the following formula:
[33]
Legend for [33]
TC = Valve closing time
TR = Reflection time in the piping
l = Length of piping up to the location of disturbance
This means when the pressure wave returns and the valve is closed, the pressure surge according to Joukowsky fully develops.
Remedy:
TCmust be markedly longer than TR.
e.g.: TC 욷 2 · TR
13.2
Pressure surges as a result of inlet pressure fluctuations in the case of PBUs with cascade control
If the inlet pressure increases, the pump curves shift upwards and the base load pump is stopped at a higher volume flow (Fig. 27). This results in an increased flow velocity change as the pump stops, thus generating pressure surges!
Remedy:
A pressure reducer/controller has to be installed upstream of the pressure boosting unit to prevent detrimental effects.
Impact of inlet pressure increase by 0.3 bar
Discharge pressure
Example:
Pressure development of a system with 3 pumps with increasing flow rate (consumption)
with decreasing flow rate (consumption)
p (co -ci)
p E p A H 0
Q co, normal Q co, inlet pressure increase by 0.3 bar Q D
Fig. 27:
Operating characteristics of a pressure boosting unit with cascade control, i. e. without speed
l Valve pressure wave Location of disturbance, e.g. T-piece Fig. 26: a ⌬⌯ = — · ⌬v [m] g 2 · l TC 울 TR = ———a [s]
14
Standards, directives and statutory regulations
14
Standards, directives and statutory regulations
DIN 1988 (December 1988 edition)
Codes of practice for drinking water installations (TRWI); general; - DVGW1code of practice
Part 1, General
includes among others:
Competences, technical terms, graphic symbols and designations
Part 2, Planning and operation; component parts, apparatus and materials
includes among others:
Piping units, valves, apparatus, drinking water heating units, drinking water tanks, drinking water treat- ment equipment, measuring and metering instruments.
Part 2, Sheet 1
Compilation of standards and other technical specifications regarding materials, components, apparatus.
Part 3, Calculating the pipe diameters
includes among others:
Calculation flow rate and flow pressure, application of conversion curve(s) of total flow to peak flow, selection of piping diameter, circulation pipes and circulation pumps, calculation examples; Annex A: forms for calculation
Part 3, Sheet 1, Calculation examples
Part 4, Protection of drinking water, drinking water quality control
includes among others:
Causes for impairment and endangering of drinking water quality, equipment preventing back flow, protection of drinking water in water heating units
Part 5, Boosting and pressure reduction
includes among others:
Pressure boosting units and pressure reducers
Part 6, Fire-fighting and fire protection installations
includes among others:
Terms, configuration and requirements, commissioning
Part 7, Prevention of corrosion damage and calcareous deposit formation
includes among others:
Part 8, Operation of plants
includes among others:
Commissioning, operation, damage and faults, maintenance information Annex A Information on maintenance measures
Annex B Inspection and maintenance schedule
Annex C Sample forms for commissioning and instruction reports
DIN 2000 (November 1973 edition)
Centralized drinking water supply; principles for drinking water requirements, planning, construction and operation of units
DIN 2001 (February 1983 edition)
Individual drinking water supply; principles for drinking water requirements, planning, construction and operation of units; DVGW code of practice
DIN 4109, Part 5 (October 1989 edition)
Sound insulation in building construction
EN 1717 (February 1995 edition)
Protection against pollution of potable water installations and general requirements of devices to prevent pollution by backflow
DIN 4807, Part 5 (March 1997 edition)
Direct flow membrane pressure vessels in drinking water installations
DIN 14200 (June 1979 edition)
Nozzle discharge
IfSG – Protection Against Infection Act (01.2001)
Act regulating the prevention of and protection against communicable diseases in humans
LMBG – Foodstuffs and Commodities Act (09.1997)
Official food control law for food, tobacco, cosmetic products and other commodities to protect health and to safeguard consumers’ rights
TrinkwV 2001 – Drinking Water Ordinance
Regulation for the quality of water for human use
VDI Directives
Directives issued by the Association of German Engineers
Standards, directives and statutory regulations
14
Standards, directives and statutory regulations
Group Group I Group III Group IV
classification
울 PN 25
p · V 울 200 p · V > 200; p · V > 1000; > 1 bar p · V 울 1000
Operating pressure > 1 bar Operating pressure > 1 bar
Single tests Pressure vessel code (DruckbehV) § 9, Testing prior to commissioning
In the case of a pressure vessel which has been subjected to an ac- ceptance test at another location – excluding the installation test – and not applicable provided with an acceptance certificate accordingly, it is sufficient that
the installation at the place of operation is checked by an expert and that this is confirmed in writing, e. g. through a commissioning/acceptance report
Pressure vessel code (DruckbehV) § 10 Regular testing
(1) In accordance with sections 4 to 9, a group IV pressure vessel must be subjected to regular testing carried out by an expert (e. g. TÜV) at defined intervals. Regular testing not applicable not applicable
(4) Groups IV and VII pressure vessels must be subjected to internal tests every five years; pressure tests must be carried out every ten years and external tests must be performed every two years.
Allocation of Accumulator PN 10 ; 80 l PN 10; 180 l, 300 l, 400 l, 800 l, 1000 l membrane type (PN 16; 12 l) PN 16; 80 l, 180 l, 300 l, 400 l, 800 l, 1000 l pressure vessel
(accumulator) sizes
Regulation governing plant safety (BetrSichV, 27.09.2002 edition)
Excerpt (special, manufacturer-related aspects have to be considered)
Table 2:
15
Inspection, maintenance and repair to DIN 1988, Part 8
Inspection, maintenance and repair: According the manufacturers’ operating instructions
Carried out by: Installation contractor
Interval: Annually unless otherwise specified by the manufacturer
Inspection, maintenance and repair
16
Nomenclature
16
Nomenclature
Description Symbols Unit
Propagation velocity of a pressure wave a m/s
Simultaneity factor f -
Acceleration due to gravity (9.81 m/s2) g m/s2
Pump discharge head H m
Max. pump discharge head at zero flow rate (Q = 0) H0 m
Static head loss Hgeo m
Floor height Hfl m
Head loss HL m
Head increase ∆H m
Static pressure loss for floor X ∆Hgeo (floor X) m
Number of pumps (incl. stand-by pump) n -
Number of floors which have to be protected against Nflpr - inadmissible pressures by means of pressure reducers
Number of floors which can be supplied without PBU Nwithout PBU -
Pressure p bar
Maximum pump pressure at zero flow rate (Q = 0) p0 bar
Cut-out pressure, pressure at which one pump of a pco bar
pressure-controlled PBU cuts out
Cut-in pressure, pressure at which one pump of a pci bar
pressure-controlled PBU cuts in Setpoint (of a speed controlled PBU)
Flow pressure at consumer pflow bar
Minimum flow pressure at consumer pmin,flow bar
Minimum flow pressure at consumer in floor N pmin,flow(N) bar Minimum supply pressure (at hand-over point between
local provider and consumer) pmin,V bar
Maximum pressure pmax bar
Maximum flow pressure at consumer pmax,flow bar
Maximum pressure per floor pmax,fl bar
Maximum supply pressure (at hand-over point between
local provider and consumer) pmax,V bar
Required pressure downstream of the PBU pdischarge bar
Available pressure upstream of the PBU pinl bar
Minimum available pressure upstream of the PBU pinl,min bar
Maximum pressure upstream of the PBU pinl,max bar
Description Symbols Unit
Pressure drop during pump start-up ∆p1 bar
Pressure increase during pump shutdown ∆p2 bar
Apparatus pressure loss ∆pap bar
Difference between cut-in/-out pressures ∆p(co-ci) bar
Maximum pressure difference downstream of the PBU ∆pPBU,max bar
Dynamic pressure difference ∆pdyn bar
Dynamic pressure loss per floor ∆pdyn,fl bar
Static pressure loss ∆pgeo bar
Static pressure loss per floor ∆pgeo,fl bar
Static pressure loss for floor X ∆pgeo (floorX) bar
Pressure loss per floor ∆pfl bar
Total pressure loss per floor ∆pfl,tot bar
Pressure fluctuation upstream of the PBU ∆pinl bar
Water meter pressure loss ∆pwm bar
Permissible pressure loss ∆pperm. bar
Mean pressure drop in consumer supply pipes ∆p/l mbar/m
Cut-out flow rate of the last pump in operation (without after-run period) Qco m3/h PBU design flow rate = nominal flow rate of a PBU (V·max) QD m3/h
Maximum volume flow of a PBU incl. stand-by pump QDS m3/h
Fire-fighting water volume flow QFfw m3/h
Critical minimum flow rate of pressure-dependent cascade control Qcrit m3/h
Minimum flow rate Qmin m3/h
Maximum permissible volume flow of filling device Qmax m3/h Maximum permissible volume flow from water supply network Qmax,netw m3/h
Nominal flow rate of water meters Qn m3/h
Nominal flow rate of PBU QN m3/h
Filling volume flow Qfill m3/h
Water supply network volume flow Qnetw m3/h
Low or permanent consumption dependent on usage Qconsumer, small m3/h Nomenclature
16
Nomenclature
Description Symbols Unit
Volume flow difference ∆Q m3/h
Volume flow change of a highly dynamic consumer ∆Qmax,dyn m3/h
Change of nominal flow rate per pump ∆QPU m3/h
Switching frequency S -
Period of time required to fill a hydrant pipe up to the wall-mounted t s fire hydrant which is most unfavourably located
Inlet tank buffering period t h
Time difference ∆t s
Closing time of valve TC s
Reflection time in the pipeline TR s
Flow velocity v m/s
Flow velocity difference ∆v m/s
Usable volume of the atmospheric inlet tank VIT m3
Accumulator volume Vaccum. m3
Gross accumulator volume Vgross m3
Total accumulator volume Vtot m3
Contents of network piping Vpipe m3
Calculation flow rate of a tap/fitting Vcal m3
Total accumulator volume Vtot m3
Volume difference ∆V m3
Nominal flow rate of water meters V·n m3/h
Minimum flow rate V·min m3/h
Nominal flow rate of a PBU = design flow rate of a PBU (QD) V·max m3/h
Maximum volume flow of a PBU pump V·max,p m3/h
Calculation flow rate of a wall-mounted fire hydrant V·cal l/s
Peak flow rate of a PBU V·peak l/s
Sum of all calculation flow rates of all taps/fittings to be supplied ΣV·cal l/s
Pipe friction and other losses Σ(R · I+Z) bar
Pipe friction and other losses from supply pipe up to PBU Σ(R · I+Z)inl bar Pipe friction and other losses downstream of PBU Σ(R · I+Z)discharge bar
Mean pressure drop in a pipe R bar/m
Individual friction losses Z bar
Pipe length I m
Sum of pipe length from PBU to the hydraulically least favourable extraction point ΣIdischarge m
Accumulator efficiency e -