• No se han encontrado resultados

Escenario Actual (Cuadrante Sur poniente y Metropolitano)

CAPITULO 3: Antecedentes Generales del Mega Proyecto Inmobiliario “Portal

3.2 Aspectos de la Oferta Inmobiliaria

3.2.1 Escenario Actual (Cuadrante Sur poniente y Metropolitano)

PERFORMED OPERATION DESCRIPTION

Twice LMC on the Add Span button in the Elevation Definition dialog box

LMC on the Cantilever Right field Defines a right side cantilever. LMC on the Span Geometry tab Switches to the Span Geometry tab. Select graphically the cantilever.

LMC in the Length field and enter value 5.0,

Apply

LMC on the middle span on the

Elevation - Beam viewer

Selects graphically the middle span of the beam.

LMC in the Length field and enter

12+1/2*12= Apply

Defines the middle span length using a simple mathematical operation in Robot Millennium edit field.

LMC in the Width field (Left support) and enter 1ft8in=

LMC on the Width field (Right

support) and enter 1ft8in= Apply

Defines the support width using a unit conversion in Robot

Millennium edit field.

LMC in the middle span in the

Elevation - Beam viewer

Selects graphically the middle span of the beam.

LMC on the h field (Basic

Dimensions) in the Section

Definition dialog box and enter

value 30.0 (in),

Apply

LMC on the box for selection of the

Robot Millennium layout

RC Beam / Beam - openings

Selects the Robot Millennium program layout allowing for the beam opening definition. The screen will be divided into three parts: a graphic viewer containing the beam elevation at the upper side, a Beam - openings table in bottom left side and the Openings dialog box at bottom right side. LMC on the middle span on the

Elevation - Beam viewer

Selects graphically the middle span of the beam.

LMC in the Name field of the

Openings dialog box and enter A as

the opening name

Defines the opening name.

LMC on the Start field and select left

upper

LMC on the X Local field and enter value 8.5, next LMC on the Z Local field and enter value 2.0

Defines the opening position on the span.

LMC on the Adjoining beam option Defines the opening type. LMC on the Lx field and enter value

1.0, next LMC on the Lz field and enter value 2.0

Defines opening dimensions.

Add Adds the A opening to the span.

LMC on the cantilever on the

Elevation - Beam viewer

Selects graphically the beam’s cantilever.

LMC on the Name field of the

Openings dialog box and enter B as

the opening name

Defines the opening name.

LMC on the Round option Defines the opening type. LMC on the X Local field and enter

value 2.0, next LMC on the Z Local field and enter value 1.0

Defines the opening position on the span.

LMC on the D field and enter value 1.0

Defines opening dimensions.

Add Adds the B opening to the span.

LMC on the box for selection of the

Robot Millennium layout

RC Beam / Beam - loads

Selects the Robot Millennium program layout allowing for the beam loads definition. The screen will be divided into three parts: a graphic viewer containing the beam static model at the upper side, a Beam - loads table in bottom left side and the Loads dialog box at bottom right side.

, Add

Select live load

LMC on the Value p1 field and enter value 2.0,

Add

Select concentrated

Select live load

LMC on the Suspended option LMC on the Value F field and enter value 12.0,

Add

Analysis / Calculation options Opens the Calculation options dialog box.

LMC on the Concrete tab. LMC in the list of the typical concrete resistance. Select fc’=4.0 ksi concrete

Defines concrete parameters.

LMC on the Longitudinal

reinforcement tab. LMC in the steel

list. Select Grade 60 steel.

Defines longitudinal reinforcement steel grade.

LMC on the None button (Bar list) to remove the default bars list.

LMC in the #8, #9, #10, #11 options to define acceptable bar list

Defines the longitudinal reinforcement acceptable bar list.

LMC on the Transversal

reinforcement tab. LMC on the steel

list. Select Grade 40 steel.

Defines the transversal reinforcement steel grade.

LMC on the #6 option to add bar #6 to acceptable bar list.

Defines transversal reinforcement acceptable bar list.

LMC on the Save As … button Opens Enter the name dialog box. LMC on the edit control, highlight

Standard text and enter test_rnf as

a new name,

OK, OK

Saves user calculation options.

LMC on the Transversal reinforcement tab

LMC on the Suspended load button LMC on the second Reinforcement

Method option, OK

See the picture on the next page.

LMC on the Structural Reinforcement tab

LMC on the Consideration of load

capacity option, OK

Analysis / Calculation Opens the Calculation Option Set dialog box.

LMC on the When the calculations

are completed go to the: Results layout option

LMC on the Calculations button Starts the calculations LMC on the OK button in the

Reinforcement concrete and

Calculation Errors dialog boxes.

Accepts the calculation warning: Axial force will not be taken

into consideration in calculations.

LMC on the Span option Defines range of the graphic viewer.

Select Deflection

LMC on the box for selection of the

Robot Millennium layout

RC Beam / Beam - reinforcement

Selects the Robot Millennium program layout allowing for the beam reinforcement presentation. The screen will be divided into four parts: two graphic viewers containing the beam elevation at the upper right side and beam section at the upper left side, a Beam - Reinforcement Table at bottom right side and Reinforcing bars dialog box at bottom left side.

Results / Calculation note Opens the Calculation note dialog box.

LMC on OK button Generates the calculation note.

LMC on the cross in the upper right corner

Closes the Calculation note editor.

File / Save Project Component As Opens the Project Component Save dialog box.

LMC on the cross near Standard

Level field in the Structure tree

Unfolds the Standard Level sub-tree.

LMD on the Beam1 field Highlights “Beam1” - standard sub-project name. Enter “My beam” in the highlighted

field,

OK

Renames the subproject name.

LMC on the OK button in the Robot message box

Accepts data saving on the standard project.

Enter the following text: “Examples Beam ACI” in the File Name field in Widows® Save As… dialog box,

Save

Saves Robot Millennium project as “Examples Beam ACI.rtd” file.

Results / Drawings Generates Final Drawings. The Robot Millennium program layout is changed automatically.

File / Print Opens the Print dialog box.

14. RC Column Design - ACI Code (Robot Stand-Alone