14.3.11 PROTOCOL REPORT

14.3.12 GDI TIMEOUT

Function • Select to generate a report to a specific destination when toner empty status occurs in the engine.

Use

Setting/

procedure

• The default setting is OFF.

ON: Generate a report to report destination.

“OFF”: Not to generate report.

• If “ON” is selected, select generate report and send to remote side when toner runs out.

• Enter the telephone number for which the report is to be produced.

• Fax number specifications: An up-to-20-digit number that may consist of [0-9], [*], [#], [pause], and [space]. (0-9, #, *, pause, _)

• The report will generate after 20 minutes, 24 hours, 48 hours, or 72 hours after the event has occurred or until the condition is gone.

NAME:ABC 123 TEL:1234567 DATE: Jun 10.2008 15:12

The Fax’s following conditions were appears, the machine may be can not work correctly, the Fax already send a report to your dealer automatically. They will contact with you soon.

Toner Cartridge Cyan : Empty Toner Cartridge Magenta : Full Toner Cartridge Yellow : Full Toner Cartridge Black : Full

SERVICE REPORT

A0FDF3C500DA

Function • Print communication report.

• Choose one from among the following.

Use

Setting/

procedure

• The default setting is OFF.

“OFF”: Disable T.30 communication report.

ON: Print T.30 communication report.

ON (ERROR): Print T.30 communication report when an error occurs.

Function

• To specify the time for GDI time out.

Use Setting/

procedure

• The default setting is 60 sec.

5 sec / 10 sec / 20 sec / 30 sec / 40 sec / 50 sec / “60 sec”

14. SERVICE MODE Field Service Ver. 1.2 Jun. 2010

magicolor 1680MF magicolor 1690MF

ADJUSTMENT/SETTING

14.3.13 TWAIN TIMEOUT

14.3.14 ENERGY SAVE MODE

14.3.15 ENABLE WARNING A. T/C LOW

B. I/C LOW

14.4 ADJUST

• Different adjust items are applicable and the corresponding adjust values become valid according to the specific sub-function of the main function (Copy, Fax, Twain, or NetScan) as detailed below.

Function

• To specify the time for TWAIN time out.

Use Setting/

procedure

• The default setting is 6 min.

2min / 4min / “6min” / 8min / 10min / 12min / 14min / 16min / 18min

Function • Set weather to activate Energy Save mode when print job receiving or panel operation have not been made for a given period.

Use Setting/

procedure

• The default setting is ON.

“ON” / OFF

Function

• Specifies whether or not a warning appears when the toner is about to run out.

Use Setting/

procedure

• The default setting is ON.

“ON” / OFF

Function • Specifies whether or not a warning appears when the print unit is about to reach the end of its service life.

Use Setting/

procedure

• The default setting is ON.

“ON” / OFF

Function

Copy Fax Twain Scan

Adjust item CIS ADF CIS ADF CIS ADF CIS ADF

CIS MAIN ZOOM { { { { X X X X

Field Service Ver. 1.2 Jun. 2010 14. SERVICE MODE

129

magicolor 1680MF magicolor 1690MF

ADJUSTMENT/SETTING

14.4.1 CIS MAIN ZOOM

Function • To adjust for variations in the accuracy of IR parts and their mounting accuracy by varying the scanning zoom ratio in the main scanning direction.

Use

• When the MFP board has been replaced.

• When the scanner unit has been replaced.

NOTE

• When the MFP board is replaced, the setting value is cleared. Re-entering a new setting value is necessary.

Adjustment Specification

• Adjust the width of D in the copy of the test pattern1 so that the following specification is met.

• 100 ± 0.5% (Zoom Ratio = Full Size:100%)

Adjustment Range

• The default setting is 0%.

• -2.0% ~ “0%” ~ +2.0%

• Step: 0.2%

Setting/

Procedure

1. Print the test pattern1.

See P.143

2. Enter the [ADJUST] menu in the service mode.

3. Select [CIS MAIN ZOOM] of [ADJUST] and press the Select key.

4. Place the test pattern1 on the Original Glass and make a test copy.

NOTE

• The test pattern1 should be positioned vertically.

• Use A4 or Letter paper loaded into tray1 to make the test copy.

5. Check that the width of D in the copy of the test pattern1 meets the specification.

Calculation: (1 - Width of D in the document ÷ Width of D in the copy) × 100 If the width of D is out of specification, adjust it according to the following procedure.

6. Press the Select key.

7. Using the S/T key, change the setting value and then press the Select key.

8. Place the test pattern1 on the Original Glass. Then, make a test copy again and check it.

Adjustment Instructions

• If the width of D in the test pattern is longer than the specified width ... Decrease the setting.

• If the width of D in the test pattern is shorter than the specified width ... Increase the setting.

4139F3C548DA

D

14. SERVICE MODE Field Service Ver. 1.2 Jun. 2010

magicolor 1680MF magicolor 1690MF

ADJUSTMENT/SETTING

14.4.2 CIS SUB ZOOM

Function • To adjust for variations in the accuracy of IR parts and their mounting accuracy by varying the scanning zoom ratio in the sub-scanning direction.

Use

• When the MFP board has been replaced.

• When the Scanner unit has been replaced NOTE

• When the MFP board is replaced, the setting value is cleared. Re-entering a new setting value is necessary.

Adjustment Specification

• Adjust the width of E in the copy of the test pattern1 so that the following specification is met.

• 200 ± 0.5% (Zoom Ratio = Full Size:100%)

Adjustment Range

• The default setting is 0%.

• -2.0% ~ “0%” ~ +2.0%

• Step: 0.2%

Setting/

Procedure

1. Print the test pattern1.

See P.143

2. Enter the [ADJUST] menu in the service mode.

3. Select [CIS SUB ZOOM] of [ADJUST] and press the Select key.

4. Place the test pattern1 on the Original Glass and make a test copy.

NOTE

• The test pattern1 should be positioned vertically.

• Use A4 or Letter paper loaded into tray1 to make the test copy.

5. Check that the width of E in the copy of the test pattern1 meets the specification.

Calculation: (1 - Width of E in the document ÷ Width of E in the copy) × 100 If the width of E is out of specification, adjust it according to the following procedure.

6. Press the Select key.

7. Using the S/T key, change the setting value and then press the Select key.

8. Place the test pattern1 on the Original Glass. Then, make a test copy again and check it.

Adjustment Instructions

• If the width of E in the test pattern is longer than the specified width ... Decrease the setting.

• If the width of E in the test pattern is shorter than the specified width ... Increase the setting.

4139F3C549DA

E

Field Service Ver. 1.2 Jun. 2010 14. SERVICE MODE

131

magicolor 1680MF magicolor 1690MF

ADJUSTMENT/SETTING

14.4.3 CIS MAIN REGIST

Function • To adjust for variations in the accuracy of IR parts and their mounting accuracy by vary-ing the scannvary-ing start position in the main scannvary-ing direction.

Use

• When the MFP board has been replaced.

• When the original glass is replaced.

• When the Scanner unit has been replaced NOTE

• When the MFP board is replaced, the setting value is cleared. Re-entering a new setting value is necessary.

• After the [CIS MAIN ZOOM] adjustments have been performed

Adjustment Specifica-tion

• Adjust the amount that widths A and B in the copy of the test pattern1 so that the follow-ing specification is met.

• 0 ± 2.0 mm

Adjustment Range

• The default setting is 0.

• -5.0 (-5.0 mm) ~ “0.0 (0.0 mm)” ~ +5.0 (+5.0 mm)

• Step: 0.5 mm

Setting/

Procedure

1. Print the test pattern1.

See P.143

2. Enter the [ADJUST] menu in the service mode.

3. Select [CIS MAIN REGIST] of [ADJUST] and press the Select key.

4. Place the test pattern1 on the Original Glass and make a test copy.

NOTE

• The test pattern1 should be positioned vertically.

• Use A4 or Letter paper loaded into tray1 to make the test copy.

5. Check the amount that widths A and B in the copy of the test pattern are shifted.

If the shift is out of specification, adjust it according to the following procedure.

6. Press the Select key.

7. Using the S/T key, change the setting value and then press the Select key.

8. Place the test pattern1 on the Original Glass. Then, make a test copy again and check it.

Adjustment Instructions

• If the width of A is less than the width of B... Increase the setting.

• If the width of B is less than the width of A... Decrease the setting.

4139F3C546DA

A B

14. SERVICE MODE Field Service Ver. 1.2 Jun. 2010

magicolor 1680MF magicolor 1690MF

ADJUSTMENT/SETTING

14.4.4 CIS SUB REGIST

Function • To adjust for variations in the accuracy of IR parts and their mounting accuracy by varying the scanning start position in the sub-scanning direction.

Use

• When the MFP board has been replaced.

• When the original glass is replaced.

• When the Scanner unit has been replaced NOTE

• When the MFP board is replaced, the setting value is cleared. Re-entering a new setting value is necessary.

• After the [CIS SUB ZOOM] adjustments have been performed

Adjustment Specification

• Adjust the width of C in the copy of the test pattern1 so that the following specification is met.

• 20 ± 2.5 mm

Adjustment Range

• The default setting is 0.

• -5.0 (-5.0 mm) ~ “0 (0 mm)” ~ +5.0 (+5.0 mm)

• Step: 0.5 mm

Setting/

Procedure

1. Print the test pattern1.

See P.143

2. Enter the [ADJUST] menu in the service mode.

3. Select [CIS SUB REGIST] of [ADJUST] and press the Select key.

4. Place the test pattern1 on the Original Glass and make a test copy.

NOTE

• The test pattern1 should be positioned vertically.

• Use A4 or Letter paper loaded into tray1 to make the test copy.

5. Check that the width of C in the copy of the test pattern are shifted.

If the width of C is out of specification, adjust it according to the following procedure.

6. Press the Select key.

7. Using the S/T key, change the setting value and then press the Select key.

8. Place the test pattern1 on the Original Glass. Then, make a test copy again and check it.

Adjustment Instructions

• If the width of C in the test pattern is longer than the specified width ... Increase the setting.

• If the width of C in the test pattern is shorter than the specified width ... Decrease the setting.

4139F3C547DA

C

Field Service Ver. 1.2 Jun. 2010 14. SERVICE MODE

133

magicolor 1680MF magicolor 1690MF

ADJUSTMENT/SETTING

14.4.5 ADF SUB ZOOM

Function

• To adjust for variations in the accuracy of all parts and their mounting accuracy by vary-ing the scannvary-ing zoom ratio in the sub-scannvary-ing direction (1-side) when usvary-ing the Auto-matic Document Feeder.

Use

• When the MFP board has been replaced.

• When the original glass is replaced.

• When a new Auto Document Feeder Unit is mounted NOTE

• When the MFP board is replaced, the setting value is cleared. Re-entering a new setting value is necessary.

• After the [CIS SUB ZOOM] adjustments have been performed

Adjustment Specifica-tion

• Adjust the length of E in the copy of the test pattern so that the following specification is met.

1. Print the test pattern1.

See P.143

2. Enter the [ADJUST] menu in the service mode.

3. Select [ADF SUB ZOOM], and press the Select key.

4. Place test pattern 1 in the ADF with its printed surface up.

5. Select [TEST COPY] and press the Select key to make a test copy.

NOTE

• The test pattern1 should be positioned vertically.

• Use A4 or Letter paper loaded into tray1 to make the test copy.

6. Check that the width of E in the copy of the test pattern1 meets the specification.

Calculation: (1 - Width of E in the document ÷ Width of E in the copy) × 100 If the width of E is out of specification, adjust it according to the following procedure.

7. Select [ADJUST], and press the Select key.

8. Using the S/T key, change the setting value and then press the Select key.

9. Place the test pattern1 into the Automatic Document Feeder. Then, make a test copy again and check it.

Adjustment Instructions

• If the width of E in the test pattern is longer than the specified width ... Decrease the setting.

• If the width of E in the test pattern is shorter than the specified width ... Increase the setting.

4139F3C549DA

E

14. SERVICE MODE Field Service Ver. 1.2 Jun. 2010

magicolor 1680MF magicolor 1690MF

ADJUSTMENT/SETTING

14.4.6 ADF MAIN REG

Function

• To adjust for variations in the accuracy of all parts and their mounting accuracy by vary-ing the scannvary-ing start position in the main scannvary-ing direction (1-side) when usvary-ing the Automatic Document Feeder.

Use

• When the MFP board has been replaced.

• When the original glass is replaced.

• When a new Auto Document Feeder Unit is mounted NOTE

• When the MFP board is replaced, the setting value is cleared. Re-entering a new setting value is necessary.

• After the [CIS SUB ZOOM] adjustments have been performed

• After the [ADF SUB ZOOM] adjustments have been performed

Adjustment Specifica-tion

• Adjust the amount that widths A and B in the copy of the test pattern1 so that the follow-ing specification is met.

• 0 ± 2.0 mm

1. Print the test pattern1.

See P.143

2. Enter the [ADJUST] menu in the service mode.

3. Select [ADF MAIN REG], and press the Select key.

4. Place test pattern 1 in the ADF with its printed surface up.

5. Select [TEST COPY] and press the Select key to make a test copy.

NOTE

• The test pattern1 should be positioned vertically.

• Use A4 or Letter paper loaded into tray1 to make the test copy.

6. Check the amount that widths A and B in the copy of the test pattern are shifted.

If the shift is out of specification, adjust it according to the following procedure.

7. Select [ADJUST], and press the Select key.

8. Using the S/T key, change the setting value and then press the Select key.

9. Place the test pattern1 into the Automatic Document Feeder. Then, make a test copy again and check it.

Adjustment Instructions

• If the width of A is less than the width of B... Increase the setting.

• If the width of B is less than the width of A... Decrease the setting.

4139F3C546DA

A B

Field Service Ver. 1.2 Jun. 2010 14. SERVICE MODE

135

magicolor 1680MF magicolor 1690MF

ADJUSTMENT/SETTING

14.4.7 ADF SUB REG

Function

• To adjust for variations in the accuracy of all parts and their mounting accuracy by vary-ing the scannvary-ing start position in the sub-scannvary-ing direction (1-side) when usvary-ing the Automatic Document Feeder.

Use

• When the MFP board has been replaced.

• When the original glass is replaced.

• When a new Auto Document Feeder Unit is mounted NOTE

• When the MFP board is replaced, the setting value is cleared. Re-entering a new setting value is necessary.

• After the [CIS SUB ZOOM] adjustments have been performed

• After the [ADF SUB ZOOM] adjustments have been performed

Adjustment Specifica-tion

• Adjust the width of C in the copy of the test pattern1 so that the following specification is met.

1. Print the test pattern1.

See P.143

2. Enter the [ADJUST] menu in the service mode.

3. Select [ADF SUB REG], and press the Select key.

4. Place test pattern 1 in the ADF with its printed surface up.

5. Select [TEST COPY] and press the Select key to make a test copy.

NOTE

• The test pattern1 should be positioned vertically.

• Use A4 or Letter paper loaded into tray1 to make the test copy.

6. Check that the width of C in the copy of the test pattern are shifted.

If the width of C is out of specification, adjust it according to the following procedure.

7. Select [ADJUST], and press the Select key.

8. Using the S/T key, change the setting value and then press the Select key.

9. Place the test pattern1 into the Automatic Document Feeder. Then, make a test copy again and check it.

Adjustment Instructions

• If the width of C in the test pattern is longer than the specified width ... Increase the setting.

• If the width of C in the test pattern is shorter than the specified width ... Decrease the setting.

4139F3C547DA

C

14. SERVICE MODE Field Service Ver. 1.2 Jun. 2010

magicolor 1680MF magicolor 1690MF

ADJUSTMENT/SETTING

14.4.8 FLICKER

14.4.9 TOP ADJUSTMENT

14.4.10 LEFT ADJ. (FRONT)

14.4.11 LEFT ADJ. (BACK)

Function • Eliminates flickers of a room fluorescent light when it occurs due to power source use environment or similar reason.

Use • Use when the fluorescent light flickers due to power source use environment or similar reason.

Setting/

procedure

• The default setting is 0.

“0”: Flicker control is determined according to an area code.

1: Flicker control is always on.

2: Flicker control is always off.

Function • Adjusts the top margin of media for single-sided printing.

Use

• To correct a misaligned print image.

PLAIN PAPER : Adjust the head margin of plain paper.

THICK : Adjust the head margin of thick paper.

ENVELOPE : Adjust the head margin of envelope.

Setting /procedure

1. Select [TOP ADJUSTMENT] and press the Select key.

2. Select desired paper type and press the Select key.

3. Select desired adjustment amount with the up keyS/down keyT and press the Select key.

-15 to +15 (1 step: 0.21 mm)

Function • Adjusts the left margin of media for single-sided printing.

Use

• To correct a misaligned print image.

TRAY 1: Adjust the left margin of media fed from tray 1 (manual tray.) TRAY 2: Adjust the left margin of media fed from tray 2.

Setting /procedure

1. Select [LEFT ADJ. (FRONT)] and press the Select key.

2. Select desired tray and press the Select key.

3. Select desired adjustment amount with the up keyS/down keyT and press the Select key.

-15 to +15 (1 step: 0.21 mm)

Function • Adjusts the left margin of media for double-sided printing.

Use

• To correct a misaligned print image.

TRAY 1: Adjust the left margin of duplex print media fed from tray 1 (manual tray.) TRAY 2: Adjust the left margin of duplex print media fed from tray 2.

Setting /procedure

1. Select [LEFT ADJ. (BACK)] and press the Select key.

2. Select desired tray and press the Select key.

3. Select desired adjustment amount with the up keyS/down keyT and press the Select key.

-15 to +15 (1 step: 0.21 mm)

Field Service Ver. 1.2 Jun. 2010 14. SERVICE MODE

137

magicolor 1680MF magicolor 1690MF

ADJUSTMENT/SETTING

14.4.12 TRANSFER POWER A. SIMPLEX PASS