14.3.11 PROTOCOL REPORT
14.3.12 GDI TIMEOUT
Function • Select to generate a report to a specific destination when toner empty status occurs in the engine.
Use
Setting/
procedure
• The default setting is OFF.
ON: Generate a report to report destination.
“OFF”: Not to generate report.
• If “ON” is selected, select generate report and send to remote side when toner runs out.
• Enter the telephone number for which the report is to be produced.
• Fax number specifications: An up-to-20-digit number that may consist of [0-9], [*], [#], [pause], and [space]. (0-9, #, *, pause, _)
• The report will generate after 20 minutes, 24 hours, 48 hours, or 72 hours after the event has occurred or until the condition is gone.
NAME:ABC 123 TEL:1234567 DATE: Jun 10.2008 15:12
The Fax’s following conditions were appears, the machine may be can not work correctly, the Fax already send a report to your dealer automatically. They will contact with you soon.
Toner Cartridge Cyan : Empty Toner Cartridge Magenta : Full Toner Cartridge Yellow : Full Toner Cartridge Black : Full
SERVICE REPORT
A0FDF3C500DA
Function • Print communication report.
• Choose one from among the following.
Use
Setting/
procedure
• The default setting is OFF.
“OFF”: Disable T.30 communication report.
ON: Print T.30 communication report.
ON (ERROR): Print T.30 communication report when an error occurs.
Function
• To specify the time for GDI time out.
Use Setting/
procedure
• The default setting is 60 sec.
5 sec / 10 sec / 20 sec / 30 sec / 40 sec / 50 sec / “60 sec”
14. SERVICE MODE Field Service Ver. 1.2 Jun. 2010
magicolor 1680MF magicolor 1690MF
ADJUSTMENT/SETTING
14.3.13 TWAIN TIMEOUT
14.3.14 ENERGY SAVE MODE
14.3.15 ENABLE WARNING A. T/C LOW
B. I/C LOW
14.4 ADJUST
• Different adjust items are applicable and the corresponding adjust values become valid according to the specific sub-function of the main function (Copy, Fax, Twain, or NetScan) as detailed below.
Function
• To specify the time for TWAIN time out.
Use Setting/
procedure
• The default setting is 6 min.
2min / 4min / “6min” / 8min / 10min / 12min / 14min / 16min / 18min
Function • Set weather to activate Energy Save mode when print job receiving or panel operation have not been made for a given period.
Use Setting/
procedure
• The default setting is ON.
“ON” / OFF
Function
• Specifies whether or not a warning appears when the toner is about to run out.
Use Setting/
procedure
• The default setting is ON.
“ON” / OFF
Function • Specifies whether or not a warning appears when the print unit is about to reach the end of its service life.
Use Setting/
procedure
• The default setting is ON.
“ON” / OFF
Function
Copy Fax Twain Scan
Adjust item CIS ADF CIS ADF CIS ADF CIS ADF
CIS MAIN ZOOM { { { { X X X X
Field Service Ver. 1.2 Jun. 2010 14. SERVICE MODE
129
magicolor 1680MF magicolor 1690MF
ADJUSTMENT/SETTING
14.4.1 CIS MAIN ZOOM
Function • To adjust for variations in the accuracy of IR parts and their mounting accuracy by varying the scanning zoom ratio in the main scanning direction.
Use
• When the MFP board has been replaced.
• When the scanner unit has been replaced.
NOTE
• When the MFP board is replaced, the setting value is cleared. Re-entering a new setting value is necessary.
Adjustment Specification
• Adjust the width of D in the copy of the test pattern1 so that the following specification is met.
• 100 ± 0.5% (Zoom Ratio = Full Size:100%)
Adjustment Range
• The default setting is 0%.
• -2.0% ~ “0%” ~ +2.0%
• Step: 0.2%
Setting/
Procedure
1. Print the test pattern1.
See P.143
2. Enter the [ADJUST] menu in the service mode.
3. Select [CIS MAIN ZOOM] of [ADJUST] and press the Select key.
4. Place the test pattern1 on the Original Glass and make a test copy.
NOTE
• The test pattern1 should be positioned vertically.
• Use A4 or Letter paper loaded into tray1 to make the test copy.
5. Check that the width of D in the copy of the test pattern1 meets the specification.
Calculation: (1 - Width of D in the document ÷ Width of D in the copy) × 100 If the width of D is out of specification, adjust it according to the following procedure.
6. Press the Select key.
7. Using the S/T key, change the setting value and then press the Select key.
8. Place the test pattern1 on the Original Glass. Then, make a test copy again and check it.
Adjustment Instructions
• If the width of D in the test pattern is longer than the specified width ... Decrease the setting.
• If the width of D in the test pattern is shorter than the specified width ... Increase the setting.
4139F3C548DA
D
14. SERVICE MODE Field Service Ver. 1.2 Jun. 2010
magicolor 1680MF magicolor 1690MF
ADJUSTMENT/SETTING
14.4.2 CIS SUB ZOOM
Function • To adjust for variations in the accuracy of IR parts and their mounting accuracy by varying the scanning zoom ratio in the sub-scanning direction.
Use
• When the MFP board has been replaced.
• When the Scanner unit has been replaced NOTE
• When the MFP board is replaced, the setting value is cleared. Re-entering a new setting value is necessary.
Adjustment Specification
• Adjust the width of E in the copy of the test pattern1 so that the following specification is met.
• 200 ± 0.5% (Zoom Ratio = Full Size:100%)
Adjustment Range
• The default setting is 0%.
• -2.0% ~ “0%” ~ +2.0%
• Step: 0.2%
Setting/
Procedure
1. Print the test pattern1.
See P.143
2. Enter the [ADJUST] menu in the service mode.
3. Select [CIS SUB ZOOM] of [ADJUST] and press the Select key.
4. Place the test pattern1 on the Original Glass and make a test copy.
NOTE
• The test pattern1 should be positioned vertically.
• Use A4 or Letter paper loaded into tray1 to make the test copy.
5. Check that the width of E in the copy of the test pattern1 meets the specification.
Calculation: (1 - Width of E in the document ÷ Width of E in the copy) × 100 If the width of E is out of specification, adjust it according to the following procedure.
6. Press the Select key.
7. Using the S/T key, change the setting value and then press the Select key.
8. Place the test pattern1 on the Original Glass. Then, make a test copy again and check it.
Adjustment Instructions
• If the width of E in the test pattern is longer than the specified width ... Decrease the setting.
• If the width of E in the test pattern is shorter than the specified width ... Increase the setting.
4139F3C549DA
E
Field Service Ver. 1.2 Jun. 2010 14. SERVICE MODE
131
magicolor 1680MF magicolor 1690MF
ADJUSTMENT/SETTING
14.4.3 CIS MAIN REGIST
Function • To adjust for variations in the accuracy of IR parts and their mounting accuracy by vary-ing the scannvary-ing start position in the main scannvary-ing direction.
Use
• When the MFP board has been replaced.
• When the original glass is replaced.
• When the Scanner unit has been replaced NOTE
• When the MFP board is replaced, the setting value is cleared. Re-entering a new setting value is necessary.
• After the [CIS MAIN ZOOM] adjustments have been performed
Adjustment Specifica-tion
• Adjust the amount that widths A and B in the copy of the test pattern1 so that the follow-ing specification is met.
• 0 ± 2.0 mm
Adjustment Range
• The default setting is 0.
• -5.0 (-5.0 mm) ~ “0.0 (0.0 mm)” ~ +5.0 (+5.0 mm)
• Step: 0.5 mm
Setting/
Procedure
1. Print the test pattern1.
See P.143
2. Enter the [ADJUST] menu in the service mode.
3. Select [CIS MAIN REGIST] of [ADJUST] and press the Select key.
4. Place the test pattern1 on the Original Glass and make a test copy.
NOTE
• The test pattern1 should be positioned vertically.
• Use A4 or Letter paper loaded into tray1 to make the test copy.
5. Check the amount that widths A and B in the copy of the test pattern are shifted.
If the shift is out of specification, adjust it according to the following procedure.
6. Press the Select key.
7. Using the S/T key, change the setting value and then press the Select key.
8. Place the test pattern1 on the Original Glass. Then, make a test copy again and check it.
Adjustment Instructions
• If the width of A is less than the width of B... Increase the setting.
• If the width of B is less than the width of A... Decrease the setting.
4139F3C546DA
A B
14. SERVICE MODE Field Service Ver. 1.2 Jun. 2010
magicolor 1680MF magicolor 1690MF
ADJUSTMENT/SETTING
14.4.4 CIS SUB REGIST
Function • To adjust for variations in the accuracy of IR parts and their mounting accuracy by varying the scanning start position in the sub-scanning direction.
Use
• When the MFP board has been replaced.
• When the original glass is replaced.
• When the Scanner unit has been replaced NOTE
• When the MFP board is replaced, the setting value is cleared. Re-entering a new setting value is necessary.
• After the [CIS SUB ZOOM] adjustments have been performed
Adjustment Specification
• Adjust the width of C in the copy of the test pattern1 so that the following specification is met.
• 20 ± 2.5 mm
Adjustment Range
• The default setting is 0.
• -5.0 (-5.0 mm) ~ “0 (0 mm)” ~ +5.0 (+5.0 mm)
• Step: 0.5 mm
Setting/
Procedure
1. Print the test pattern1.
See P.143
2. Enter the [ADJUST] menu in the service mode.
3. Select [CIS SUB REGIST] of [ADJUST] and press the Select key.
4. Place the test pattern1 on the Original Glass and make a test copy.
NOTE
• The test pattern1 should be positioned vertically.
• Use A4 or Letter paper loaded into tray1 to make the test copy.
5. Check that the width of C in the copy of the test pattern are shifted.
If the width of C is out of specification, adjust it according to the following procedure.
6. Press the Select key.
7. Using the S/T key, change the setting value and then press the Select key.
8. Place the test pattern1 on the Original Glass. Then, make a test copy again and check it.
Adjustment Instructions
• If the width of C in the test pattern is longer than the specified width ... Increase the setting.
• If the width of C in the test pattern is shorter than the specified width ... Decrease the setting.
4139F3C547DA
C
Field Service Ver. 1.2 Jun. 2010 14. SERVICE MODE
133
magicolor 1680MF magicolor 1690MF
ADJUSTMENT/SETTING
14.4.5 ADF SUB ZOOM
Function
• To adjust for variations in the accuracy of all parts and their mounting accuracy by vary-ing the scannvary-ing zoom ratio in the sub-scannvary-ing direction (1-side) when usvary-ing the Auto-matic Document Feeder.
Use
• When the MFP board has been replaced.
• When the original glass is replaced.
• When a new Auto Document Feeder Unit is mounted NOTE
• When the MFP board is replaced, the setting value is cleared. Re-entering a new setting value is necessary.
• After the [CIS SUB ZOOM] adjustments have been performed
Adjustment Specifica-tion
• Adjust the length of E in the copy of the test pattern so that the following specification is met.
1. Print the test pattern1.
See P.143
2. Enter the [ADJUST] menu in the service mode.
3. Select [ADF SUB ZOOM], and press the Select key.
4. Place test pattern 1 in the ADF with its printed surface up.
5. Select [TEST COPY] and press the Select key to make a test copy.
NOTE
• The test pattern1 should be positioned vertically.
• Use A4 or Letter paper loaded into tray1 to make the test copy.
6. Check that the width of E in the copy of the test pattern1 meets the specification.
Calculation: (1 - Width of E in the document ÷ Width of E in the copy) × 100 If the width of E is out of specification, adjust it according to the following procedure.
7. Select [ADJUST], and press the Select key.
8. Using the S/T key, change the setting value and then press the Select key.
9. Place the test pattern1 into the Automatic Document Feeder. Then, make a test copy again and check it.
Adjustment Instructions
• If the width of E in the test pattern is longer than the specified width ... Decrease the setting.
• If the width of E in the test pattern is shorter than the specified width ... Increase the setting.
4139F3C549DA
E
14. SERVICE MODE Field Service Ver. 1.2 Jun. 2010
magicolor 1680MF magicolor 1690MF
ADJUSTMENT/SETTING
14.4.6 ADF MAIN REG
Function
• To adjust for variations in the accuracy of all parts and their mounting accuracy by vary-ing the scannvary-ing start position in the main scannvary-ing direction (1-side) when usvary-ing the Automatic Document Feeder.
Use
• When the MFP board has been replaced.
• When the original glass is replaced.
• When a new Auto Document Feeder Unit is mounted NOTE
• When the MFP board is replaced, the setting value is cleared. Re-entering a new setting value is necessary.
• After the [CIS SUB ZOOM] adjustments have been performed
• After the [ADF SUB ZOOM] adjustments have been performed
Adjustment Specifica-tion
• Adjust the amount that widths A and B in the copy of the test pattern1 so that the follow-ing specification is met.
• 0 ± 2.0 mm
1. Print the test pattern1.
See P.143
2. Enter the [ADJUST] menu in the service mode.
3. Select [ADF MAIN REG], and press the Select key.
4. Place test pattern 1 in the ADF with its printed surface up.
5. Select [TEST COPY] and press the Select key to make a test copy.
NOTE
• The test pattern1 should be positioned vertically.
• Use A4 or Letter paper loaded into tray1 to make the test copy.
6. Check the amount that widths A and B in the copy of the test pattern are shifted.
If the shift is out of specification, adjust it according to the following procedure.
7. Select [ADJUST], and press the Select key.
8. Using the S/T key, change the setting value and then press the Select key.
9. Place the test pattern1 into the Automatic Document Feeder. Then, make a test copy again and check it.
Adjustment Instructions
• If the width of A is less than the width of B... Increase the setting.
• If the width of B is less than the width of A... Decrease the setting.
4139F3C546DA
A B
Field Service Ver. 1.2 Jun. 2010 14. SERVICE MODE
135
magicolor 1680MF magicolor 1690MF
ADJUSTMENT/SETTING
14.4.7 ADF SUB REG
Function
• To adjust for variations in the accuracy of all parts and their mounting accuracy by vary-ing the scannvary-ing start position in the sub-scannvary-ing direction (1-side) when usvary-ing the Automatic Document Feeder.
Use
• When the MFP board has been replaced.
• When the original glass is replaced.
• When a new Auto Document Feeder Unit is mounted NOTE
• When the MFP board is replaced, the setting value is cleared. Re-entering a new setting value is necessary.
• After the [CIS SUB ZOOM] adjustments have been performed
• After the [ADF SUB ZOOM] adjustments have been performed
Adjustment Specifica-tion
• Adjust the width of C in the copy of the test pattern1 so that the following specification is met.
1. Print the test pattern1.
See P.143
2. Enter the [ADJUST] menu in the service mode.
3. Select [ADF SUB REG], and press the Select key.
4. Place test pattern 1 in the ADF with its printed surface up.
5. Select [TEST COPY] and press the Select key to make a test copy.
NOTE
• The test pattern1 should be positioned vertically.
• Use A4 or Letter paper loaded into tray1 to make the test copy.
6. Check that the width of C in the copy of the test pattern are shifted.
If the width of C is out of specification, adjust it according to the following procedure.
7. Select [ADJUST], and press the Select key.
8. Using the S/T key, change the setting value and then press the Select key.
9. Place the test pattern1 into the Automatic Document Feeder. Then, make a test copy again and check it.
Adjustment Instructions
• If the width of C in the test pattern is longer than the specified width ... Increase the setting.
• If the width of C in the test pattern is shorter than the specified width ... Decrease the setting.
4139F3C547DA
C
14. SERVICE MODE Field Service Ver. 1.2 Jun. 2010
magicolor 1680MF magicolor 1690MF
ADJUSTMENT/SETTING
14.4.8 FLICKER
14.4.9 TOP ADJUSTMENT
14.4.10 LEFT ADJ. (FRONT)
14.4.11 LEFT ADJ. (BACK)
Function • Eliminates flickers of a room fluorescent light when it occurs due to power source use environment or similar reason.
Use • Use when the fluorescent light flickers due to power source use environment or similar reason.
Setting/
procedure
• The default setting is 0.
“0”: Flicker control is determined according to an area code.
1: Flicker control is always on.
2: Flicker control is always off.
Function • Adjusts the top margin of media for single-sided printing.
Use
• To correct a misaligned print image.
PLAIN PAPER : Adjust the head margin of plain paper.
THICK : Adjust the head margin of thick paper.
ENVELOPE : Adjust the head margin of envelope.
Setting /procedure
1. Select [TOP ADJUSTMENT] and press the Select key.
2. Select desired paper type and press the Select key.
3. Select desired adjustment amount with the up keyS/down keyT and press the Select key.
-15 to +15 (1 step: 0.21 mm)
Function • Adjusts the left margin of media for single-sided printing.
Use
• To correct a misaligned print image.
TRAY 1: Adjust the left margin of media fed from tray 1 (manual tray.) TRAY 2: Adjust the left margin of media fed from tray 2.
Setting /procedure
1. Select [LEFT ADJ. (FRONT)] and press the Select key.
2. Select desired tray and press the Select key.
3. Select desired adjustment amount with the up keyS/down keyT and press the Select key.
-15 to +15 (1 step: 0.21 mm)
Function • Adjusts the left margin of media for double-sided printing.
Use
• To correct a misaligned print image.
TRAY 1: Adjust the left margin of duplex print media fed from tray 1 (manual tray.) TRAY 2: Adjust the left margin of duplex print media fed from tray 2.
Setting /procedure
1. Select [LEFT ADJ. (BACK)] and press the Select key.
2. Select desired tray and press the Select key.
3. Select desired adjustment amount with the up keyS/down keyT and press the Select key.
-15 to +15 (1 step: 0.21 mm)
Field Service Ver. 1.2 Jun. 2010 14. SERVICE MODE
137
magicolor 1680MF magicolor 1690MF
ADJUSTMENT/SETTING
14.4.12 TRANSFER POWER A. SIMPLEX PASS