When you open the Filter dialog, active filters are shown (see Fig. 6.4.1.-1). Items are presented in their default states. The list items on the right-hand side appear in ascending order. Filter settings allow you to choose one selective or unselective set of object identifiers, function and alarm class. You can combine the selections with the OR operator. Note, that it is not possible to search a station-name from an unsorted list.

A060528

Fig. 6.4.1.-1 The Filter Settings dialog

You can add condition sets to the list. The condition sets are separated with the operator OR. Every set includes OI1-OI5, functions, alarm classes and custom condition (SCIL).

You can remove a condition set from a list by selecting a line of the set and clicking

Delete

. You can add new sets with the

New

button. The new sets are appended to the end of the condition list. The

Delete

button is disabled, if none of condition set lines are selected.

Activate a condition set line to view all possible selections on the multi-selection list on the right side of the Filter Settings dialog. The caption of the selection list shows which items the user is currently selecting, for example All Bays:, All functions:. You can activate the selective selection by selecting one OI1 item from the list and clicking

Next

or double-clicking OI1. Next, the OI-row of the condition set list is selected. The selection list shows only OI-items received accoring to previous OI- selections. The Selection list caption is set to for example Devices of Bay Eastwick/ Transformer 1. The

Back

button clears the currently selected line of the condition set list and moves to previous line.

The selective selection is deactivated if you change the selection of the condition set list or the selected item for last object identifier (OI5).

The Condition line selected Custom of the condition set list hides the selection list on the right and shows a text box instead. User inputs custom condition line to text box and clicks

Accept

.

121 By default, the Lower or Upper Time Limit are not set. The Lower or Upper Time Limit can be activated by selecting them. The date and time limits can be defined by using the arrow buttons or by typing the information into the appropriate boxes directly. When the date limit is defined, the date selector component is displayed on the screen.

If the Lower and/or the Upper Time Limit has been selected in the upper part of the Filters dialog, the limits can be set by clicking Edit and by entering the desired date and time in the dialog which appears on the screen. In case the Lower and/or the Upper Time Limits in the Filters dialog have been selected, the fields below are unavailable but indicate the unselected date and time.

If the Selective Filter option is set, only the items concerning the substation in the drop-down list can be selected. This means that only bays that belong to the substation, are available in the Bay drop-down list. Similarly, only devices that belong to the selected bay, can be selected in the Device drop-down list.

If the Unselective Filters option is set, the items concerning bay and device can be selected in the respective drop-down lists without limitations. It is, for example, possible to select a device without selecting a bay or a substation. As a result, all the devices with the selected name will be displayed in filtered data, regardless of the bay or station. The lower part of the Filter dialog contains the drop-down lists where it is possible to select one alarm class out of the available alarm classes. When using alarm classes, the signals that have the same functional purpose are usually included in the same alarm class.

To view the other options provided, click the More button in the Filter dialog. You can select Save Preconfiguration, Load Preconfiguration or Advanced

Condition.

Advanced condition

To define an advanced filter condition, select the Custom Condition > Edit in the Filter dialog. Then the Advanced Condition dialog is opened (see Fig. 6.4.1.-2). In this dialog, it is possible to define an advanced filter condition by using attributes found in the process database and by using a set of comparison operators and condition values. It is also possible to type in the filter condition directly in the Filter text box.

advancedcondition_b

Fig. 6.4.1.-2 Advanced Condition dialog

OK closes the dialog and accepts the specified filter. Cancel discards all the changes

and closes the dialog. Clear clears the contents of the specified filter. Help opens the Help dialog.

Selecting objects to the filter configuration

Search filtering can be done in the Filter dialog (see Fig. 6.4.1.-1) with the help of the five combo boxes. If Selective Filter is in use, the selections become active one at a time. For example, when the Substation drop-down list is selected, the Bay drop- down list becomes active. If Unselective Filter is in use, all the drop-down lists that are configured to be used in the system, are active. Option All is selected as a default, which is indicated as a star character in the drop-down list meaning that all the signals below the level are included.

6.4.2.

Saving filter setting

To save active filter settings, select More > Save Preconfiguration in the Filter Settings dialog. The Save Preconfiguration dialog is opened, in which you can specify the file name and the folder for the preconfiguration file. Define the location of the preconfiguration in the Visibility field. When you select the Application

specific option button, the preconfiguration becomes accessible for all the users of

the application, see Fig. 6.4.2.-1. Clear the Show in menu check box to hide a preconfiguration. Click Save to save the preconfiguration file. Click Cancel to close the dialog without saving. For more information about saving preconfigurations, refer to Section 8.2.3. Saving preconfiguration.

123

A060553

Fig. 6.4.2.-1 Visibility definition