NOTE:
If you have tried to program the system on a keypad that was not properly installed, the programming cannot be saved.
Add the keypad to the system and program it again.
Power LED Flashing Rapidly Indicating a System Power LED Flashing Rapidly Indicating a System Power LED Flashing Rapidly Indicating a System Power LED Flashing Rapidly Indicating a System Trouble Condition
Trouble Condition Trouble Condition Trouble Condition
Problem: If the power LED flashes rapidly, it is indicating a system trouble condition. To investigate the trouble condition, press quick keys [✳✳✳✳] [3] [1] and enter the code. If there is more than one trouble condition, the key can be used to scroll down through them.
Solution: System troubles can be dealt with, as follows:
✦✸ MAIN: LOW BATT: Indicates that there is no battery or that the battery is faulty or needs recharging. A new battery test can be forced as described in the ProSYS User’s Manual).
✦✸ MAIN: AC TROUBLE: Indicates that the mains power has been lost. Check the mains input and mains input fuse. Rectify as necessary.
✦✸ MAIN: BELL: Indicates that the internal bell is either faulty or not connected. If an internal bell is not required, then a 2K2 resistor must be fitted across the BELL/LS terminals to negate the bell loop trouble.
✦✸ MAIN: AUX TRBL: Indicates a failure of the Auxiliary 12V DC power supply. Check for short circuits on the power BUS.
✦✸ FALSE CODE P=X: Indicates that an incorrect code has repeatedly been keyed. Once trouble has been displayed, it is automatically removed.
Appendix A:
Appendix A:
Appendix A:
Appendix A: Technical Data Technical Data Technical Data Technical Data
Main Panel
Input Power 16.5 Volts AC @ 40 Volt-Amps (VA) (via integral transformer) Current Consumption 60 mA, typical / 70 mA, maximum
Rechargeable Standby Battery
12 Volts up to 17 Amp-Hours (AH), typical
Power Outputs:
❖✸ Auxiliary Power
❖✸ Bell/LS (External) Sounder Output
12 Volts DC @ 600 mA, maximum (from all AUX terminals) 12 Volts DC @ 900 mA, maximum
Programmable Voltage (Utility) Output
UO1: Relay (programmable output) (3 Amps) UO2: 500 mA transistor
UO3-UO6: Open Collector Active Pull-Down, 70 mA, maximum
Cabinet Dimensions 37.5 cm x 33 cm x 9.8 cm Main Board Dimensions 20 cm x 11.5 cm x 6.5 cm F3 Responsible for:
Battery Power
3.0 A
AUX Automatic fuse Fuses
BELL Automatic fuse
Keypads (8 LED/16 LED/KCL/KCLP)
Current Consumption 8 LED 32 mA, typical / 72 mA maximum 16 LED 32 mA, typical / 72 mA maximum
KCL 75 mA maximum
Proximity KCL 100 mA maximum Main Panel Connection 4-wire BUS, up to 300 m from Main Panel Dimensions 16.2 cm x 12.2 cm x 3 cm
Zone Expansion Module: 8-Zone
Current Consumption 25 mA, typical / 30 mA, maximum
Main Panel Connection 4-wire BUS, up to 300 m from Main Panel Dimensions 10.5 cm x 6.6 cm x 1.8 cm
Zone Expansion Module: 16-Zone
Current Consumption 27 mA, typical / 34 mA, maximum
Main Panel Connection 4-wire BUS, up to 300 m from Main Panel Dimensions 16.5 cm x 6.6 cm x 1.8 cm
Wireless Expansion Modules 8-/16-Zone
Current Consumption 12-15 mA
Frequency 868.6-868.7 MHz (narrowband operation in EU) Receiving Range 200 m (Key fob) - 800 m (detectors)
Dimensions 14.5 cm x 9 cm x 3.8 cm
Utility Output Expansion Module: 4-Output
Current Consumption 25 mA, typical / 140 mA, maximum Contacts 4 Form C (SPDT) Relays
Contact rating: 5 A / 24V DC
Main Panel Connection 4-wire BUS, up to 300 m from Main Panel Dimensions 10.5 cm x 6.6 cm x 2.2 cm
Utility Output Expansion Module: 8-Output
Current Consumption 25 mA, typical / 30 mA, maximum
Contacts Open Collector, Active Pull-Down, 70 mA, maximum Main Panel Connection 4-wire BUS, up to 300 m from Main Panel
Dimensions 10.5 cm x 6.6 cm x 1.8 cm
Power Supply Expansion Module
Input Power 16.5 Volts AC @ 40 VA (via transformer) Rechargeable Standby
Battery
12 Volts up to 17 Amp-Hours (AH), typical
Power Outputs:
Auxiliary Power
Bell/LS (External) Sounder Output
12 Volts DC @ 600 mA, maximum 12 Volts DC @ 900 mA, maximum
Fuses F1: Battery power 3.0 A F2: Auxiliary power 2.0 A
F3: Bell/loudspeaker power 1.0 A
Event Log Expansion Module
Current Consumption 25 mA, typical / 29 mA, maximum
Main Panel Connection 4-wire BUS, up to 300 m from Main Panel Dimensions 10.5 cm x 6.6 cm x 1.8 cm
Printer Module
Current Consumption 7 mA, typical / 10 mA, maximum
Main Panel Connection 4-wire BUS, up to 300 m from Main Panel Dimensions 6.2 cm x 5.3 cm x 1.6 cm
X-10 Transmitter Module
Current Consumption 25 mA, typical / 29 mA, maximum
Main Panel Connection 4-wire BUS, up to 300 m from Main Panel Dimensions 10.5 cm x 6.6 cm x 1.8 cm
Access Control Module
Input Power 13.8V DC + 10%
Current Consumption 100 mA maximum
Main Panel Connection 4-wire BUS RS-485, up to 300 m from the Main Panel Readers Consumption 5V / 150 mA maximum
Dimensions 16.5 cm x 8.8 cm x 2.1 cm
Relay 24V DC / 1 A maximum
Voice Module
Input Power 12V DC
Current Consumption 6 mA, typical/26 mA maximum Dimensions 6.6 cm x 6.6 cm x 1.8 cm
Weight 20.44 mg
Electronic Key
Current Consumption 11 mA, typical / 17 mA maximum Main Panel Connection 4-wire BUS, up to 1000 ft (300 m) Dimensions 3.4 cm x 1.9 cm x 1.2 cm
Advance Voice Module
Current Consumption (standby/active speaking)
38 mA / 57 mA
Audio Signal Max = 5V pp / Max = 2V Dimensions 16.5 cm x 6.6 cm x 1.8 cm
Voice Message Unit
Input Power 8V DC to 14V DC
Current Consumption 9 mA (standby) / 60 mA (active apeaking - normal volume) / 130 mA (active speaking - full volume)
Augio Signal V in max = 2.5V pp / V out max = 4V pp Dimensions 6.2 cm x 11.3 cm x 3.2 cm
Appendix B:
Appendix B:
Appendix B:
Appendix B: ProSYS Accessories ProSYS Accessories ProSYS Accessories ProSYS Accessories
Keypads Description
RP128KL0800A 8-LED Keypad
RP128KL1600A 16-LED Keypad
RP128KCL000A LCD Keypad, Custom (large display)
RP128KCLP00A Proximity LCD Keypad, Custom Plus (large display) + 2 key tags
Zone Expanders Description
RP296EZ8 Zone Expansion Module (8-Zone) RP296EZ16 Zone Expansion Module (16-Zone)
RP128EZ8F00A Zone Expansion Module (8-Zone) with FAST and extended loop response definitions
Wireless Zone Expanders Description
RP128EW0800A Wireless Zone Expansion (Receiver) Module (8-Zone), 868 MHz RP128EW1600A Wireless Zone Expansion (Receiver) Module (16-Zone), 868 MHz
Wireless Transmitters Description
RWT92086800A Wireless PIR detector 868 MHz
RWT92P86800A Wireless PIR detector with pet immunity 868 MHz RWT32S86800A Wireless smoke detector 868 MHz
RWT72C86800A Wireless door contact transmitter 868 MHz
RWT72M86800A Wireless door contact + magnet transmitter 868 MHz RWT72P86800A Wireless universal / Shutter transmitter 868 MHz RP128T4RC00A 4-button rolling code transmitter 868 MHz
Power Supply Expanders Description
RP296EPS Power Supply Expansion Module
Programmable Output Devices
Description
RP296EO4 Utility Output Expansion Module (4-Relay Outputs: Form C) RP296EO8 Utility Output Expansion Modules (8 Open-Collector Outputs)
Printer Module Description
RP296PRT Printer Module
Access Control Description
RP128EAC000A Access Control Module
RP128EAR100A Proximity reader
RP128EAR200A Proximity reader + keypad
RP128EAC100A Proximity card
RP128EAC200A Thin proximity card
Digital Key Description
RP128EKXX00A Digital Key Reader XX=reader type RP128EKG000A Pack of 10 key tags
Voice Module Description
RP200VC Voice Module
Advanced Voice Unit Description
RP128EV00XXA Advanced voice module with extensive message, remote DTMF control, and remote listen and talk capabilities
XX=language
Message Box Unit Description
RP128EVM000A Listen and speak-in module with message box RP128EVL000A Listen and speak-in module
X-10 Module Description
RP296XT X-10 Transmitter Module
Uploading/Downloading Description
RP128UDIN000A Upload/Download Software (for IBM Compatible PCs) RP128EE000A Program Transfer Module
RP296EBA BUS adapter (cable) used for local PC-based Uploading/Downloading operations, as follows:
✦✸ Connected between a PC’s serial (COM) port and the ProSYS J1 connector
✦✸ Requires Upload/Download software (above) and includes a required converter adapter terminated in a female DB25-type connector (it may be necessary to obtain a 25-pin male to 9-pin female adapter if required by your PC’s COM Port) RP128EUSB00A USB/485 converter for on-site use to connect between a PC USB
port and the ProSYS J1 serial connection
Miscellaneous Description
RP128B2 Metal box for ProSYS Main Panel and accessories RP128DB00XXA ProSYS demonstration board