• No se han encontrado resultados

Exposición a los riesgos ocupacionales y consecuencias

NOTE:

If you have tried to program the system on a keypad that was not properly installed, the programming cannot be saved.

Add the keypad to the system and program it again.

Power LED Flashing Rapidly Indicating a System Power LED Flashing Rapidly Indicating a System Power LED Flashing Rapidly Indicating a System Power LED Flashing Rapidly Indicating a System Trouble Condition

Trouble Condition Trouble Condition Trouble Condition

Problem: If the power LED flashes rapidly, it is indicating a system trouble condition. To investigate the trouble condition, press quick keys [✳✳✳✳] [3] [1] and enter the code. If there is more than one trouble condition, the key can be used to scroll down through them.

Solution: System troubles can be dealt with, as follows:

✦✸ MAIN: LOW BATT: Indicates that there is no battery or that the battery is faulty or needs recharging. A new battery test can be forced as described in the ProSYS User’s Manual).

✦✸ MAIN: AC TROUBLE: Indicates that the mains power has been lost. Check the mains input and mains input fuse. Rectify as necessary.

✦✸ MAIN: BELL: Indicates that the internal bell is either faulty or not connected. If an internal bell is not required, then a 2K2 resistor must be fitted across the BELL/LS terminals to negate the bell loop trouble.

✦✸ MAIN: AUX TRBL: Indicates a failure of the Auxiliary 12V DC power supply. Check for short circuits on the power BUS.

✦✸ FALSE CODE P=X: Indicates that an incorrect code has repeatedly been keyed. Once trouble has been displayed, it is automatically removed.

Appendix A:

Appendix A:

Appendix A:

Appendix A: Technical Data Technical Data Technical Data Technical Data

Main Panel

Input Power 16.5 Volts AC @ 40 Volt-Amps (VA) (via integral transformer) Current Consumption 60 mA, typical / 70 mA, maximum

Rechargeable Standby Battery

12 Volts up to 17 Amp-Hours (AH), typical

Power Outputs:

❖✸ Auxiliary Power

❖✸ Bell/LS (External) Sounder Output

12 Volts DC @ 600 mA, maximum (from all AUX terminals) 12 Volts DC @ 900 mA, maximum

Programmable Voltage (Utility) Output

UO1: Relay (programmable output) (3 Amps) UO2: 500 mA transistor

UO3-UO6: Open Collector Active Pull-Down, 70 mA, maximum

Cabinet Dimensions 37.5 cm x 33 cm x 9.8 cm Main Board Dimensions 20 cm x 11.5 cm x 6.5 cm F3 Responsible for:

Battery Power

3.0 A

AUX Automatic fuse Fuses

BELL Automatic fuse

Keypads (8 LED/16 LED/KCL/KCLP)

Current Consumption 8 LED 32 mA, typical / 72 mA maximum 16 LED 32 mA, typical / 72 mA maximum

KCL 75 mA maximum

Proximity KCL 100 mA maximum Main Panel Connection 4-wire BUS, up to 300 m from Main Panel Dimensions 16.2 cm x 12.2 cm x 3 cm

Zone Expansion Module: 8-Zone

Current Consumption 25 mA, typical / 30 mA, maximum

Main Panel Connection 4-wire BUS, up to 300 m from Main Panel Dimensions 10.5 cm x 6.6 cm x 1.8 cm

Zone Expansion Module: 16-Zone

Current Consumption 27 mA, typical / 34 mA, maximum

Main Panel Connection 4-wire BUS, up to 300 m from Main Panel Dimensions 16.5 cm x 6.6 cm x 1.8 cm

Wireless Expansion Modules 8-/16-Zone

Current Consumption 12-15 mA

Frequency 868.6-868.7 MHz (narrowband operation in EU) Receiving Range 200 m (Key fob) - 800 m (detectors)

Dimensions 14.5 cm x 9 cm x 3.8 cm

Utility Output Expansion Module: 4-Output

Current Consumption 25 mA, typical / 140 mA, maximum Contacts 4 Form C (SPDT) Relays

Contact rating: 5 A / 24V DC

Main Panel Connection 4-wire BUS, up to 300 m from Main Panel Dimensions 10.5 cm x 6.6 cm x 2.2 cm

Utility Output Expansion Module: 8-Output

Current Consumption 25 mA, typical / 30 mA, maximum

Contacts Open Collector, Active Pull-Down, 70 mA, maximum Main Panel Connection 4-wire BUS, up to 300 m from Main Panel

Dimensions 10.5 cm x 6.6 cm x 1.8 cm

Power Supply Expansion Module

Input Power 16.5 Volts AC @ 40 VA (via transformer) Rechargeable Standby

Battery

12 Volts up to 17 Amp-Hours (AH), typical

Power Outputs:

Auxiliary Power

Bell/LS (External) Sounder Output

12 Volts DC @ 600 mA, maximum 12 Volts DC @ 900 mA, maximum

Fuses F1: Battery power 3.0 A F2: Auxiliary power 2.0 A

F3: Bell/loudspeaker power 1.0 A

Event Log Expansion Module

Current Consumption 25 mA, typical / 29 mA, maximum

Main Panel Connection 4-wire BUS, up to 300 m from Main Panel Dimensions 10.5 cm x 6.6 cm x 1.8 cm

Printer Module

Current Consumption 7 mA, typical / 10 mA, maximum

Main Panel Connection 4-wire BUS, up to 300 m from Main Panel Dimensions 6.2 cm x 5.3 cm x 1.6 cm

X-10 Transmitter Module

Current Consumption 25 mA, typical / 29 mA, maximum

Main Panel Connection 4-wire BUS, up to 300 m from Main Panel Dimensions 10.5 cm x 6.6 cm x 1.8 cm

Access Control Module

Input Power 13.8V DC + 10%

Current Consumption 100 mA maximum

Main Panel Connection 4-wire BUS RS-485, up to 300 m from the Main Panel Readers Consumption 5V / 150 mA maximum

Dimensions 16.5 cm x 8.8 cm x 2.1 cm

Relay 24V DC / 1 A maximum

Voice Module

Input Power 12V DC

Current Consumption 6 mA, typical/26 mA maximum Dimensions 6.6 cm x 6.6 cm x 1.8 cm

Weight 20.44 mg

Electronic Key

Current Consumption 11 mA, typical / 17 mA maximum Main Panel Connection 4-wire BUS, up to 1000 ft (300 m) Dimensions 3.4 cm x 1.9 cm x 1.2 cm

Advance Voice Module

Current Consumption (standby/active speaking)

38 mA / 57 mA

Audio Signal Max = 5V pp / Max = 2V Dimensions 16.5 cm x 6.6 cm x 1.8 cm

Voice Message Unit

Input Power 8V DC to 14V DC

Current Consumption 9 mA (standby) / 60 mA (active apeaking - normal volume) / 130 mA (active speaking - full volume)

Augio Signal V in max = 2.5V pp / V out max = 4V pp Dimensions 6.2 cm x 11.3 cm x 3.2 cm

Appendix B:

Appendix B:

Appendix B:

Appendix B: ProSYS Accessories ProSYS Accessories ProSYS Accessories ProSYS Accessories

Keypads Description

RP128KL0800A 8-LED Keypad

RP128KL1600A 16-LED Keypad

RP128KCL000A LCD Keypad, Custom (large display)

RP128KCLP00A Proximity LCD Keypad, Custom Plus (large display) + 2 key tags

Zone Expanders Description

RP296EZ8 Zone Expansion Module (8-Zone) RP296EZ16 Zone Expansion Module (16-Zone)

RP128EZ8F00A Zone Expansion Module (8-Zone) with FAST and extended loop response definitions

Wireless Zone Expanders Description

RP128EW0800A Wireless Zone Expansion (Receiver) Module (8-Zone), 868 MHz RP128EW1600A Wireless Zone Expansion (Receiver) Module (16-Zone), 868 MHz

Wireless Transmitters Description

RWT92086800A Wireless PIR detector 868 MHz

RWT92P86800A Wireless PIR detector with pet immunity 868 MHz RWT32S86800A Wireless smoke detector 868 MHz

RWT72C86800A Wireless door contact transmitter 868 MHz

RWT72M86800A Wireless door contact + magnet transmitter 868 MHz RWT72P86800A Wireless universal / Shutter transmitter 868 MHz RP128T4RC00A 4-button rolling code transmitter 868 MHz

Power Supply Expanders Description

RP296EPS Power Supply Expansion Module

Programmable Output Devices

Description

RP296EO4 Utility Output Expansion Module (4-Relay Outputs: Form C) RP296EO8 Utility Output Expansion Modules (8 Open-Collector Outputs)

Printer Module Description

RP296PRT Printer Module

Access Control Description

RP128EAC000A Access Control Module

RP128EAR100A Proximity reader

RP128EAR200A Proximity reader + keypad

RP128EAC100A Proximity card

RP128EAC200A Thin proximity card

Digital Key Description

RP128EKXX00A Digital Key Reader XX=reader type RP128EKG000A Pack of 10 key tags

Voice Module Description

RP200VC Voice Module

Advanced Voice Unit Description

RP128EV00XXA Advanced voice module with extensive message, remote DTMF control, and remote listen and talk capabilities

XX=language

Message Box Unit Description

RP128EVM000A Listen and speak-in module with message box RP128EVL000A Listen and speak-in module

X-10 Module Description

RP296XT X-10 Transmitter Module

Uploading/Downloading Description

RP128UDIN000A Upload/Download Software (for IBM Compatible PCs) RP128EE000A Program Transfer Module

RP296EBA BUS adapter (cable) used for local PC-based Uploading/Downloading operations, as follows:

✦✸ Connected between a PC’s serial (COM) port and the ProSYS J1 connector

✦✸ Requires Upload/Download software (above) and includes a required converter adapter terminated in a female DB25-type connector (it may be necessary to obtain a 25-pin male to 9-pin female adapter if required by your PC’s COM Port) RP128EUSB00A USB/485 converter for on-site use to connect between a PC USB

port and the ProSYS J1 serial connection

Miscellaneous Description

RP128B2 Metal box for ProSYS Main Panel and accessories RP128DB00XXA ProSYS demonstration board