1. Operating Method

1) Launching the Normal Test Mode

To start Test Mode, switch ON the machine power while simultaneously pressing the left and right keys of the vertical print positioning.

The firmware version number is displayed when the Test Mode is launched.

Press the Stop Key or Cancel Key to go into standby mode.

From the standby mode, enter the required test mode number and press Start Key to activate.

Press the Stop Key or Cancel Key to return back to the standby mode.

Enter next desired test mode number to continue using the test mode, or press the Reset Key for one second to escape out from the Test Mode.

The Reset Key must be pressed (for 1 second) to escape out from the Test Mode only when the machine is in the standby mode of the test mode.

2) Launching the Protected Area Test Mode

Launch the machine into normal test mode and to the standby mode.

Enter the four digit password to go into the Protected Area Test Mode, which is 9874, and press the Start Key. The Protected Area Test Mode is launched.

Enter the desired protected area test mode number and press the Start Key to activate.

To escape out from the Protected Area Test Mode, press the Stop Key or Cancel Key and then press the Cancel Key for one second. This will return the machine back to the normal machine operating condition.

No. Sensors, switches Detection status 0003 24V A output signal 24V-A ON (24V output)

0004 24V B output signal 24V-B ON (24V output)

No. Unit check

0080 Test Print A (checkered)

Creates Test pattern 1 (Checker Flag) 0081 Test Print B (cross stripes)

Creates Test pattern 2 (Cross Lines) 0082 Test Print C (Dot1)

Creates Test pattern 3 (Dot 1 ) 0083 Test Print D (Dot2)

Creates Test pattern 4 (Dot 2 ) 0084 Test Print E (Dot 1 x Dot 1)

Creates Test pattern 5 (Dot 1 x Dot 1 ) 0085 Test Print F (Dot 2 x Dot 2 )

Creates Test pattern 6 (Dot 2 x (Dot 2) 0086 Test Print 18% dots

Creates Test pattern B4 18% dots

0087

Paper-Feed Test (continuous feeding) Prints continuously.

* The Speed key is enabled.

* If the rear cover safety switch is OFF, the operation begins when the rear cover safety switch is tur ned ON within 10 seconds after the START key is turned ON.

0088 Low-Speed Printing Operation Prints continuously at 15 rpm.

0090

Continuous master-making & printing

Continuous master-making & printing with test mode master-making without using original on the AF unit.

* The printing quantity is set by Test Mode No. 0147.

* The test mode master-making type is selected by Test Mode No. 0148.

0094

Unit Initialization

Initializes the mechanical moving units to their home positions.

[ Scanner, thermal print head, compression plate, clamp units and vertical print position.]

0095 System Configuration Data Output

Creates a master for the CI system data.

2. List of the Test Modes 1) System & Panel Test Modes

[ 16-4 ] KZ (Revision 1.2)

Imagetec Solutions Australia

No. Data clear Details

0110

Clearing Jam Status Data

Forcibly clears the jam.

This test mode can be used to temporary clear error display. For acutal cor -rection of the problem, the cause for the display should be corrected.

Consumable error displays cannot be cleared.

0111

Clearing User Memory

User area memory clear Initializes data in user area memory to the programming defaults Record all the settings before the test mode activation.

0112

Clearing Normal Area Test-Mode Data Memory [MACHINE]

Normal area test mode memory clear for test modes on the ma -chine.

Initializes all normal area test mode settings on the machine EEPROM to their programming default values.

The initializing is effective after rebooting the machine.

The protected area test modes stay unchanged.

Record all the settings before the test mode activation.

No. Data check Details

0120 Data setting change confirmation

Displays the last changed Test Mode number and its new setting.

The Test Mode No. and the setting are displayed alterately. This does not apply to the program default settings. Test modes 1200’s & 5480 and up are reflected on this test mode.

0122 Error history Displays the Error type and Error number of the last displayed error (only the last one error.)

0124 Machine Serial Number 1 Displays the left 4 digits of the machine serial number.

0125 Machine Serial Number 2 Displays the left 4 digits of the machine serial number.

0130 MCTL PCB program version display

Displays Mechanical control PCB program version. Example: Displays

"0101" for Ver.1.01

0131 System program version display Displays ROSA program version. Example: Displays "0101" for Ver.1.01

0137 Master count (software) display

The digits from ten thousand and digits thousand and under will display alternately.

Beep sound will be heard when digits ten thousand and over are displayed.

0138 Copy count (software) display

The digits from ten thousand and digits thousand and under will display alternately.

Beep sound will be heard when digits ten thousand and over are displayed.

No. Data setting

0147

Print Quantity Selection (ref: Test Mode No.0090)

Description Selects the print quantity for the continuous master-making & printing operation by Test Mode No. 0090.

Setting Selectable range : 1 to 100 (1 to 100 prints) Default : 3 (3 prints)

0148

Master-Making Type Selection (ref: Test Mode No.0090)

Description Selects the type of image for the continuous master-making & printing operation by Test Mode No. 0090.

Setting

Slow Start Printing Action

Description Activates or deactivates the slow-start printing action.

Setting 0: Inactive (default) 1: Active

0155

Counter Action Control

Description

Stops the software counter by setting to [0]. Once the power is turn OFF and turned back ON, the setting automatically changes back to the default setting of Counter Active [1].

Setting 0: Stops the counter

1: Activates the counter (default)

0162

Master Making Action Standby

Description After selecting the Master-making mode, the machine resets itself from the master-making mode after the selected time frame has passed.

Setting

Documento similar