Friction (i.e. slip critical) bolts are available for the bolt group (BGP), bolted splice (BSPL), bolted flange plate connection (FPC), and the most

common shear connections (WSP, FEP, and ACLT). When friction bolts are selected for one of these connection types Limcon automatically performs a slip check for each bolt group in the connection.

When you specify friction bolts for any connection you may also specify the bolt slip factor by clicking the adjacent Slip Check button. This will display the Bolt Slip Check dialog box shown below.

ANSI/AISC 360 ANSI/AISC 360

Whether Limcon is configured for ASD or LRFD you may choose the serviceability or strength limit state. Limcon checks the slip resistance determined from the code against the input load effects, service loads for ASD and factored loads for LRFD.

BS 5950 BS 5950

BS 5950 has friction bolt categories that are either non-slip in service or non-slip at failure (NSF). In both cases, the check is performed using factored load effects. The serviceability limit state is presented as an ultimate limit state – the code specifies different strengths for the two conditions.

EC3 EC3

EC3 has friction bolt categories that are either “slip-resistant at serviceability” (B) or “slip-resistant at ultimate” (C). In both cases, the check is performed using factored load effects. The serviceability limit state is presented as an ultimate limit state – the code specifies different strengths for the two conditions.

CAN/CSA-S16 CAN/CSA-S16

You may specify either the serviceability or strength limit state. For the serviceability limit state the load effects are determined from the strength/service load factor, which must be input. A typical value is 1.5. AS 4100 and NZS 3404

AS 4100 and NZS 3404

Bolt slip is a serviceability limit state in these codes. The load effects are determined from the strength/service load factor, which must be input. A typical value is 1.5. Limcon also allows bolt slip to be checked as a strength limit state.

IC Method IC Method

Even though the IC method may be used for the strength check in eccentrically loaded bolt groups, bolt forces for the slip check are always determined using the elastic method.

Out of Plane Forces Out of Plane Forces

The support bolt group in the flexible end plate (FEP) and angle cleat (ACLT) connections may be subject to both in-plane and out-of-plane forces. It is assumed that tension in the beam reduces the slip resistance of these bolt groups linearly to zero at the point where the bolt pretension is entirely counteracted by the axial tension (see Ref. 24, p. 341). Compression is assumed to have no effect on the slip resistance.

Welds

The dialog box below is used for choosing the welds in the welded beam/column connection (WBC) and is typical of many others.

fu: fu:

The ultimate strength of the weld material, MPa or ksi. When the configured design code is EC3 this value is not used, the weld resistance being determined by the base metal strength.

Quality: Quality:

Usually all welds are “SP”. When AS 4100 or NZS 3404 is the design code “GP” may be chosen for a lower quality weld (fillet welds only). Size:

Size:

A drop-down list box shows all available fillet weld sizes and an item for a full penetration butt weld (FPBW) or complete joint penetration groove weld (CJPGW).

When ANSI/AISC 360 is the design code complete joint penetration groove welds do not have to be checked because the strength of the joint is controlled by the base metal. The strength of a complete joint penetration groove weld should never govern.

Directional Strength of

Directional Strength of Fillet WeldsFillet Welds

ANSI/AISC 360 and CAN/CSA-S16 permit a 50% strength increase for fillet welds loaded at right angles to the length of the weld. BS 5950 and EC3 permit a directional strength increase of 25% and 22%,

respectively. When Limcon is configured for these codes the additional strength is used for fillet welds in some connections, e.g. for fillet welds between a beam flange or flange plate and a column flange. Limcon

output always shows an advisory note when the directional strength increase is utilized.

Directional strength increase is not used when Limcon is configured for AS 4100 or NZS 3404.

Weld Matching Weld Matching

Limcon implements code provisions related to weld matching for fillet welds in some connections. For ANSI/AISC 360 weld leg shear yield and shear rupture are checked while for CAN/CSA-S16 only weld leg shear rupture is checked. For BS 5950 Limcon uses the Table 37 weld design strengths, which are limited for unmatched welds. EC3 does not specify weld metal strength checks because requirements for electrodes ensure that welds are matched. AS 4100 and NZS 3404 specify compliance with AS/NZS 1554.1, which has provisions ensuring that welds are matched.

HSS Welds HSS Welds

Welds are represented as accurately as possible in the virtual reality window. In the case of HSS truss connections, each weld element is represented diagrammatically as a sector of a cylinder, whose radius equals the throat dimension, centered on the outside edge of the intersecting HSS. The exact welding details for these connections may be quite complicated, varying around the perimeter of each HSS from a

fillet weld to a full or partial penetration weld

The design of welds in HSS truss connections is not straightforward. See References 25, 52, 53, and 54 for more information. In checking the welds in the overlapped K/N connection (TKNO), Limcon makes these simplifying assumptions:

• For brace 1 the effective length of the weld may be obtained by

linear interpolation between the length for zero and the length for 100% overlap.

• For brace 2 the force on the weld may be obtained by linear

interpolation between the force for zero and the force for100% overlap.