A. Exterior concealed transition joints in air barrier.
1. Joint Sealant: Single-component neutral-curing low-modulus silicone sealant SJS#1. 2. Joint Sealant: Single-component non-sag urethane sealant UJS#1.
3. Compatibility: Compatible with air barrier components specified in Division 07 air barrier section.
JOINT SEALANTS 079200 - 7 B. Exterior construction joints in cast-in-place and pre-cast concrete panels.
1. Joint Sealant: Single-component non-sag urethane sealant UJS#2.
2. Joint-Sealant Color: As selected by Architect from manufacturer's standard colors. C. Exterior movement joints in brick masonry.
1. Joint Sealant: Single-component neutral-curing non-staining silicone sealant SJS#1. 2. Joint Sealant: Single-component non-sag urethane sealant UJS#2.
3. Joint-Sealant Color, Vertical Joints: As selected by Architect from manufacturer's standard colors.
4. Joint-Sealant Color, Horizontal Joints: As selected by Architect from manufacturer's full range.
D. Exterior exposed joints in metal panel cladding systems.
1. Joint Sealant: Single-component neutral-curing non-staining silicone sealant SJS#1. 2. Joint-Sealant Color: As selected by Architect from manufacturer's standard colors. E. Exterior concealed watertight joints in cladding systems.
1. Joint Sealant: Single-component neutral-curing silicone sealant SJS#1. 2. Joint Sealant: Single-component non-sag urethane sealant UJS#1. F. Exterior joints between different materials listed above.
1. Joint Sealant: Single-component non-sag urethane sealant UJS#2.
2. Joint-Sealant Color: As selected by Architect from manufacturer's standard colors Multiple colors required to match several conditions.
G. Exterior perimeter joints at frames of doors, windows, storefront frames, curtain wall frames, and louvers.
1. Joint Sealant: Single-component non-sag urethane sealant UJS#2.
2. Joint-Sealant Color: As selected by Architect from manufacturer's standard colors. H. Exterior joints within aluminum storefront framing, curtain walls, and window systems:
1. Joint Sealant: Single-component neutral-curing non-staining silicone sealant [SJS#__]. 2. Joint-Sealant Color: As selected by Architect from manufacturer's standard colors. I. Exterior joints within structural glazing, aluminum storefront framing, curtain walls, and
window systems: Refer to Division 08 Section ["Glazing Sealants"] ["Structural-Sealant-Glazed Curtain Walls"].
1. Joint Sealant: Single-component neutral-curing non-staining silicone sealant SJS#2. 2. Joint-Sealant Color: As selected by Architect from manufacturer's standard colors. J. All other exterior non-traffic joints.
1. Joint Sealant: Single-component neutral-curing non-staining silicone sealant SJS#2. 2. Joint Sealant: Single-component non-sag urethane sealant UJS#2.
JOINT SEALANTS 079200 - 8 3. Joint-Sealant Color: As selected by Architect from manufacturer's standard colors [
Multiple colors required to match several conditions. K. Exterior horizontal traffic and traffic isolation joints:
1. Joint Sealant: Single-component pourable urethane sealant UJS#3.
2. Joint-Sealant Color: As selected by Architect from manufacturer's standard colors. 3.4 INTERIOR JOINT-SEALANT SCHEDULE
A. Interior vertical movement joints in exterior concrete and unit masonry.
1. Joint Sealant: Single-component non-sag urethane sealant[, Greenguard certified]
UJS#1.
2. Joint-Sealant Color: As selected by Architect from manufacturer's full range. C. Interior perimeter joints of exterior aluminum frames.
1. Joint Sealant: Single-component non-sag urethane sealant[, Greenguard certified] UJS#2. 2. Joint-Sealant Color: As selected by Architect from manufacturer's full range.
E. Interior traffic joints in floor and between floor and wall construction.
1. Joint Sealant: Single-component pourable urethane sealant[, Greenguard certified]
UJS#3.
2. Joint-Sealant Color: As selected by Architect from manufacturer's full range. G. Interior non-moving joints between interior painted surfaces and adjacent materials.
1. Joint Sealant: Siliconized acrylic latex, UJS#1. 2. Joint-Sealant Color: Paintable.
I. Interior concealed sealants at thresholds and sills.
1. Joint Sealant: Butyl-rubber-based joint sealant[ BJS#1].
JOINT SEALANTS 079200 - 9 END OF SECTION 079200
STANDARD STEEL DOORS AND FRAMES 081113 - 1 SECTION 081113 - STANDARD STEEL DOORS AND FRAMES
PART 1 - GENERAL
1.1 SUMMARY
A. This Section includes standard insulated hollow-metal steel doors and frames.
1.2 SUBMITTALS
A. Product Data: Include construction details, material descriptions, core descriptions, label compliance, fire-resistance rating, and finishes for each type of steel door and frame specified. B. Shop Drawings: Provide a schedule of standard steel doors and frames using same reference
numbers for details and openings as those on Drawings.
1.3 QUALITY ASSURANCE
A. Fire-Rated Door Frame Assemblies: Assemblies complying with NFPA 80 that are listed and labeled by a testing and inspecting agency acceptable to authorities having jurisdiction, for fire- protection ratings indicated.
1. Test Pressure: Test at atmospheric (neutral) pressure according to NFPA 252 or UL 10B. 2. Test Pressure: Test according to NFPA 252 or UL 10C. After 5 minutes into the test, the
neutral pressure level in furnace shall be established at 40 inchesor less above the sill. B. Smoke-Control Door Assemblies: Comply with NFPA 105 or UL 1784.
1.4 DELIVERY, STORAGE, AND HANDLING
A. Deliver doors and frames palletized, wrapped, or crated to provide protection during transit and Project-site storage. Do not use non-vented plastic.
B. Deliver welded frames with two removable spreader bars across bottom of frames, tack welded to jambs and mullions.
PART 2 - PRODUCTS
2.1 MANUFACTURERS
A. Manufacturers: Subject to compliance with requirements, provide products by one of the following:
STANDARD STEEL DOORS AND FRAMES 081113 - 2 2. Ceco Door Products; an ASSA ABLOY Group Company.
3. CURRIES Company; an ASSA ABLOY Group Company. 4. Steelcraft; an Ingersoll-Rand Company.
2.2 MATERIALS
A. Cold-Rolled Steel Sheet: ASTM A 1008/A 1008M, Commercial Steel (CS), Type B; suitable for exposed applications.
B. Metallic-Coated Steel Sheet: ASTM A 653/A 653M, Commercial Steel (CS), Type B; with minimum A40 zinc-iron-alloy (galvannealed) coating designation.
C. Supports and Anchors: After fabricating, galvanize units to be built into exterior walls according to ASTM A 153/A 153M, Class B.
D. Inserts, Bolts, and Fasteners: Provide items to be built into exterior walls, hot-dip galvanized according to ASTM A 153/A 153M.
E. Powder-Actuated Fasteners in Concrete: Fastener system of type suitable for application indicated, fabricated from corrosion-resistant materials, with clips or other accessory devices for attaching standard steel door frames of type indicated.
F. Grout: Comply with Division 4 Section "Unit Masonry Assemblies."
G. Mineral-Fiber Insulation: ASTM C 665, Type I (blankets without membrane facing); consisting of fibers manufactured from slag or rock wool with 6- to 12-lb/cu. ft. density; with maximum flame-spread and smoke-developed indexes of 25 and 50 respectively; passing ASTM E 136 for combustion characteristics.
H. Bituminous Coating: Cold-applied asphalt mastic, SSPC-Paint 12, compounded for 15-mil dry film thickness per coat. Provide inert-type non-corrosive compound free of asbestos fibers, sulfur components, and other deleterious impurities.