Dr. ZX has three (3) modes, learning value display, parameter change, and monitor display information setting.

Learning Value Display

Displays the values set by learning function.

Parameter Change

Engine speed, pump delivery flow rate, and solenoid valve output pressure can be adjusted.

Monitor Display Information Setting

Items to be displayed on the monitor LCD can be added.

• Accessing Service Mode

1. After turning the key switch OFF, wait for more than 10 seconds.

2. Connect Dr. ZX to the connector to MC on the base machine.

3. Turn the engine learning switch to the learning position (the stamped mark E side).

4. Turn the key switch ON. Don’t start the engine at this time.

5. Turn Dr. ZX switch ON.

Except ZAXIS225US

T178-01-02-006

ZAXIS225US

T1SM-01-02-006

Dr. ZX Connector to MC

Learning Switch

Dr. ZX Connector to MC Engine Learning Switch

The learning switch is turned to the stamped mark E

Learning Switch

EC Motor Stop Position Display of the engine stop value in engine learning EC Motor Maximum Speed Position Display of max. engine speed valve in engine learning Boom Angle Sensor Correction Value Display of boom angle sensor correction value Arm Angle Sensor Correction Value Display of arm angle sensor correction value Parameter Change

Li Speed Adjustment Adjustment of minimum engine speed WU Speed Adjustment Adjustment of warming up engine speed AI Speed Adjustment Adjustment of auto-idle engine speed E Speed Adjustment Adjustment of E-mode engine speed P Speed Adjustment Adjustment of P-mode engine speed

Breaker Engine Speed Adjustment Adjustment of breaker operation engine speed Secondary Crusher (Demolisher) Engine

Speed Adjustment

Adjustment of secondary crusher (demolisher) operation engine speed

Crusher Engine Speed Adjustment Adjustment of crusher operation engine speed

Vibro-Hammer Speed Adjustment Adjustment of vibratory hammer operation engine speed Hyd. Breaker P1 Max Swash Angle

Adjustment

Adjustment of lowest pump 1 max. flow rate in breaker operation

Secondary Crusher (Demolisher) P1 Max Swash Angle Adjustment

Adjustment of lowest pump 1 max. flow rate in secondary crusher operation

Crusher P1 Max Swash Angle Adjustment Adjustment of lowest pump 1 max. flow rate in crusher operation

Vibro P1 Max Swash Angle Adjustment Adjustment of lowest pump 1 max. flow rate in vibratory hammer operation

Hyd. Breaker P2 Max Swash Angle Adjustment

Adjustment of lowest pump 2 max. flow rate in breaker operation

Secondary Crusher (Demolisher) P2 Max Swash Angle Adjustment

Adjustment of lowest pump 2 max. flow rate in secondary crusher operation

Crusher P2 Max Swash Angle Adjustment Adjustment of lowest pump 2 max. flow rate in crusher operation

Vibro P2 Max Swash Angle Adjustment Adjustment of lowest pump 2 max. flow rate in vibratory hammer operation

Pump PQ Base Torque Correction Adjustment of pump P-Q curve ATT Proportional Solenoid Valve Adjustment Adjustment of optional solenoid valve

Item Data Boom Lower Dampener Proportional

Solenoid Valve Adjustment

Adjustment of solenoid valve

ATT Speed Increase Down Waiting Time Setting of time required for engine speed increase

**ATT Torque Down ON/OFF ON/OFF of torque down control, when a front attachment is operated.

*ML Crane Front Code Change Setting of front att. code for ML models

*ML Crane Bucket Code Change Setting of bucket code for ML models Max. *ML Crane Speed Adjustment Setting of engine speed in crane mode

*ML Crane Bucket Weight Adjustment Min, Boom CYL. Bottom Pressure Over Balance

Monitor Display Change

Engine Actual Speed Display/Non-display Monitor setting of display/no-display of actual engine speed Hydraulic Oil Temperature Display/No-display Monitor setting of display/no-display of hydraulic oil

temperature

Hydraulic Oil Filter LED Display/No-display Monitor setting of ON/OFF of hydraulic oil filter LED.

NOTE: * ML specification is only available in Japanese domestic market.

** Available for ZX200 class and ZX225 class.

NOTE: The following explanation exemplifies the transition diagrams for ZAXIS200.

Start the service software in the service mode Select Start from the EPVC_Mid software menu.

T178-05-01-006

Press Correct if the displayed model name is correct.

T178-05-01-012

Confirm that you are in the service mode, and select Rechecked.

T178-05-01-034

The service software will start in the service mode

Select Special Function.

T178-05-01-035

Select the function you want to execute The menu will be displayed.

Select Learning Data Display from the menu.

T178-05-01-036

Learning data items will be displayed Select the item you want to execute.

T178-05-01-037

Fig. A Fig. B

Select ESC to return to Fig. A.

Fig.C

Select ESC to return to Fig. A.

Fig. D

Select ESC to return to Fig. A.

Fig. E

Select ESC to return to Fig. D.

Fig. F

Select ESC to return to Fig. F.

EC Motor stop position

T178-05-01-038

EC Motor Maximum engine speed position

T178-05-01-039

Boom angle sensor correction value

T178-05-01-040

Arm angle sensor correction value

T178-05-01-041

Select ESC to return

to Fig. F. Select ESC to return

to Fig. F.

Select ESC to return

to Fig. F. Select ESC to return

to Fig. F.

NOTE: The following explanation exemplifies the transition diagrams for ZAXIS200.

Start the service mode on the condition that the engine learning switch is turned on.

To change the parameter, it is necessary to enter the password. To change the password, refer to the “Changing the password”

section.

Start the service software in the service mode Select Start from the EPVC_Mid software menu.

T178-05-01-006

Press Correct if the displayed model name is correct.

T178-05-01-012

Confirm that you are in the service mode, and select Rechecked.

T178-05-01-034

The service software will start in the service mode

Select Special Function.

T178-05-01-035

Execute the parameter change

The menu will be displayed.

Select Parameter Change from the menu.

T178-05-01-042

Enter the password

Enter the password to change the parameter.

T178-05-01-043

Select a parameter change item

Select the item you want to change. The up- and down-arrow buttons can be used to scroll through the item list.

T178-05-01-044

Fig. A Fig. B

Select ESC to return to Fig. A.

Fig. C

Select ESC to return to Fig. A.

Fig. D

Select ESC to return to Fig. A

Fig. E

Select ESC to return to Fig. D.

Fig. F

Select ESC to return to Fig. E.

Fig. G

Select ESC to return to Fig. E.

Enter the new value

Enter the new value in the Adjustment space, and press Execution.

T178-05-01-045

Confirm the new value

The new value will be displayed in the Adjustment space. Select Execute to change to this value.

T178-05-01-046

Parameter adjustment result

The adjusted value will be displayed.

T178-05-01-047

Select ESC to return to Fig. G.

Select ESC to return to Fig. G.

Select ESC to return to Fig. G.

NOTE: The following explanation exemplifies the transition diagrams for ZAXIS200.

Start the service mode on the condition that the engine learning switch is turned on.

Start the service software in the service mode Select Start from the EPVC_Mid software menu.

T178-05-01-006

Press Correct if the displayed model name is correct.

T178-05-01-012

Confirm that you are in the service mode, and select Rechecked.

T178-05-01-034

The service software will start in the service mode

Select Special Function.

T178-05-01-035

Execute the monitor display change

The menu will be displayed.

Select Monitor Display from the menu.

T178-05-01-042

Select a display change item

Select the monitor display change item you want to execute.

T178-05-01-048

Select Display or No Display

Select Disp or No Disp.

T178-05-01-049

Fig. A Fig. B

Select ESC to return to Fig. A.

Fig. C

Select ESC to return to Fig. A.

Fig. D

Select ESC to return to Fig. A.

Fig. E

Select ESC to return

to Fig. D. Select ESC to return

to Fig. E.

Fig. F

Select ESC to return to Fig. F.

Fig. G

Confirm Disp/No Disp

Confirm that the Monitor space shows Disp or No Disp. If it is correctly displayed, select Execute.

T178-05-01-050

Confirm the result

It has been changed as shown on-screen. Select ESC.

T178-05-01-051

Fig. H

Select ESC to return to Fig.F.

Fig. I

Select ESC to return to Fig. F.

(Check that pump flow rate and engine speed have been changed.)

IMPORTANT: After adjusting the engine speed and flow rate to the attachment, turn the engine learning switch to neutral. If the engine is started with the engine learning switch in the engine learning position, the MC will not control the engine, pumps, and valves so that change in the pump flow rate and the engine speed cannot be checked.

1. Turn the key switch OFF.

2. Wait approx. 10 seconds.

3. Turn the engine learning switch to neutral.

4. Disconnect the Dr. ZX. connector (When monitoring with Dr. ZX, pass this step.)

5. Turn the key switch ON.

6. Start the engine.

7. Check operational performances of the machine.