This research is limited to the use of commercial LPG and R-290 as drop in 1.0 hp residential air conditioner initially designed to use R-22. The air conditioner uses the vapour compression refrigeration cycle. The study of the azeotrope and zeotropic properties and the temperature glide of the LPG blends will not be included in this research.

The testing chamber used in this study consist of the “air enthalpy method” type of installation in determining the energy efficiency ratio (EER) of split types air conditioner using the MS ISO 5151:2012 “Non-ducted air conditioner and heat pumps- testing and rating performance (1st revision)”. Since the split air conditioner

used in this test consist of a unit without “inverter controller” that controls partial loads of the compressor, it will be tested at full load conditions only. This is in accordance with the requirements of MS ISO 5151.

The simulation of leaking LPG in an enclosed space is limited to a low Mach “Large Eddy Simulation” (LES) turbulence model. 729,000 purely hexahedral cells will be used for meshes and time step size is limited to 0.1s. Run time is limited to 240 seconds which is corresponding to 4 minutes of total leak time.

REFERENCES

Ahamed, J.U., Saidur,R. and Masjuki, M.H. (2010). Thermodynamic Performance Analysis of R-600 and R-600a as Refrigerant. Engineering e- Transaction. 5(1), 11-18.

Akashi, O. and Hanoaka, T. (2012). Technological Feasibility and Cost of Achieving a 50% Reduction of Global GHG Emissions by 2050: Mid - and Long-Term Perspectives. Sustainability Science. Special Feature. 1-36

Alsaad, M.A. and Hammad, M.A. (1998). The Application of Propane/Butane Mixture for Domestic Refrigerator. Applied Thermal Engineering. 18, 911- 918.

American Heating and Refrigeration Institute (AHRI) (2015) Standard 550/590 - Standard for Performance Rating of Water-Chilling and Heat Pump Water- Heating Packages Using the Vapor Compression Cycle. Arlington, VA 22101, USA.

American Heating and Refrigeration Institute (AHRI) (2000) Standard 560 - Standard for Absorption Water Chilling and Water Heating Packages. Arlington, VA 22101, USA.

American Society of Heating, Refrigerating and Air- Conditioning Engineers, Inc. (ASHRAE), (2004). HVAC Systems and Equipment Handbook. Atlanta, GA, USA.

American Society of Heating, Refrigerating and Air- Conditioning Engineers, Inc. (ASHRAE), (2010). Refrigeration Handbook. Atlanta, GA, USA.

American Society of Heating, Refrigerating and Air- Conditioning Engineers, Inc. (ASHRAE), (2013). Fundamentals Handbook. Atlanta, GA, USA.

American Society of Heating, Refrigerating and Air- Conditioning Engineers, Inc. (ASHRAE), (2015). Applications Handbook. Atlanta, GA, USA

American Society of Heating, Refrigerating and Air- Conditioning Engineers, Inc. (ASHRAE), (2017). Fundamentals Handbook. Atlanta, GA, USA.

American Society of Heating, Refrigerating and Air- Conditioning Engineers, Inc. (ASHRAE), (2013). Standard 15. Atlanta, GA, USA.

193

American Society of Heating, Refrigerating and Air- Conditioning Engineers, Inc. (ASHRAE), (2013). Standard 34. Atlanta, GA, USA.

ANSYS FLUENT V. 12 User’s Guide.

http//www.afs.enea.it/project/neptunius/docs/fluent/html/ug/node161.htm, assessed on 01.07.2019

Arora, C.P. (2000). Refrigeration and Air Conditioning. 2nd Edition. Tata Mc- Graw Hill, New Delhi, India

Australian Institute of Refrigeration and Heating Inc. (AIRAH), (1998). Refrigeration Selection Guide. West Melbourne, Victoria, Australia

Australian Institute of Refrigeration and Heating Inc. (AIRAH), (2003). Refrigeration Selection Guide. West Melbourne, Victoria, Australia.

Australian Institute of Refrigeration and Heating Inc. (AIRAH), (2013). Flammable Refrigerants-Industry Guide. West Melbourne, Victoria, Australia

Barbosa Jr, J.R. and Neto, M.A.M. (2011). Absorption of Isobutane (R-600a) in Lubricant Oil. Chemical Engineering Science. 66, 1906-1915.

B.S. ISO 817, (2014). Refrigerants-Designation and Safety Classifications. 3rd Edition. British Standards Institution, London, U.K.

B.S. EN 378, (2013). Refrigerant Systems and Heat Pumps-Safety and Environmental Requirements. Part 1-4, British Standards Institution, London, U.K.

B.S. ISO 5151, (2010). Non-Ducted Air Conditioners and Heat Pumps- Testing and Rating for Performance, British Standards Institution, London, U.K.

B.S. ISO 5149, (2014). Refrigeration Systems and Heat Pumps-Safety and Environmental Requirements. Parts 1-4, British Standards Institution, London, U.K.

Calm, J.M. and Didion, D.A. (1998). Trade-Offs in Refrigeration Selection: Past, Present and Future. International Journal of Refrigeration. 21(4), 308-321. Campbell, N.J., and McCulloch, A. (1998). The Climate Change Implications of

Manufacturing Refrigerants- Calculation of ‘Production’ Energy Contents of Some Common Refrigerants. Trans IChemE. 36 Part B, 239-244.

Cecchinato, L., Dell’Eva, M. and Fornasieri, E. (2004). The Effects of Non- Condensable Gases in Household Refrigerators. International Refrigeration and Air Conditioning Conference at Purdue.

Chartered Institution of Building Services Engineers, (CIBSE), (2000). CFC, HCFC and Halons: Professional and Practical Guidance on Substances that Deplete the Ozone Layer. CIBSE, London, U.K.

Chartered Institution of Building Services Engineers, (CIBSE), (2002). CIBSE Guide J: Weather, Solar and Illuminance Data. CIBSE, London, U.K.

Chemours. (2016). Opteon YF automotive refrigerant – HFO-1234yf. http:www.chemours.com/refrigerants/enUS/uses_apps/automotive

_ac/SmartAutoAC/HFO-1234yf.html, assessed on 11.12.2017

Cleland, D.J., Keedwell, R.W. and Adams, S.R. (2009). Use of Hydrocarbons as Drop-In Replacements for HCFC 22 in On-Farm Milk Cooling equipment. International Journal of Refrigeration. 32, 1403-1411.

Colbourne, D & Espersen, L (2013) Quantitative Risk Assessment of R 290 in Ice Cream Cabinets. International Journal of Refrigeration. 36, 1208-1219. Colbourne, D. and Suen, K.O. (2003). Equipment Design and Installation Features to

Disperse Refrigerant Releases in Rooms-Part 1: Experiments and Analysis. International Journal of Refrigeration. 26, 667-673.

Colbourne, D. and Suen, K.O. (2003). Equipment Design and Installation Features to Disperse Refrigerant Releases in Rooms-Part 2: Determination of Procedures. International Journal of Refrigeration. 26, 674-680.

Colbourne, D & Suen, K O. (2015). Comparative evaluation of risk of a split air conditioner and refrigerator using hydrocarbon refrigerants. International Journal of Refrigeration. 59, 295-303.

Colbourne, D., Acharekar, A.A.,Wadia, B.J. and Rajadhyaksha, D. (2015).The First 100,000 HC 290 Split Air Conditioners in India. International Journal of Refrigeration. 60, 289-296.

Corberan, J.M., Segurado, J., Colbourne, D. and Gonzalvez, J. (2008). Review of Standards for Use of Hydrocarbon Refrigerants in A/C, Heat Pump and Refrigeration Equipment. International Journal of Refrigeration. 31, 748- 756.

Daikin, (2014). Water Cooled Single-Screw Chillers Catalogue. Daikin Industries, Ltd. Osaka, 5308323, Japan.

Daikin, (2015). Fluorocarbon- Types and Features of Fluorocarbon. www.daikin.com/products/fluorocarbons/index.html, accessed 18.01.2018

195 Daikin, (2017). Daikin R-32.

www.daikin.com.my/advertisements/tv/20l7/12/11/daikin-accessed 16.01.2018 Daimler, (2015), Mercedes-Benz to Equip First Vehicle Models with CO2 Air

Conditioning Systems. Daimler. 2015. www.daimler.com/investors, accessed 04.04.2017.

Dalkilic, A.S. and Wongwises, S. (2010). A Performance Comparison of Vapour- Compression Refrigeration System Using Various Refrigerants. International Communications in Heat and Mass Transfer. 37, 1340-1349.

Campbell, N.J. and McCulloch, A. (1998). The Climate Change Implications of Manufacturing Refrigerants- A Calculation of ‘Production’ Energy Contents of Some Common Refrigerants. Trans IChemE, 76(B), 239-244

Department of Environment (DOE) Malaysia, (2010). Consultative Workshop on “HCFC Phaseout Management Plan (HPMP) for Malaysia”. 4 October 2010. DOE Malaysia.

Department of Environment (DOE) Malaysia, (2015). Letter on “Extension of Time for the Ban of Manufacturing, Assembling and Importing of Air conditioning Equipment using HCFC with Capacities of 2.5 Horse Power and Below”. 22 May 2015. DOE Malaysia.

Department of Environment (DOE) Malaysia, (2018). Seminar on “Stakeholders Consultation Workshop for the Ratification of Kigali Amendment & Enabling Activities for HFC Phase Down Under the Montreal Protocol”. 2 March 2018. DOE Malaysia.

Devotta, S., Padalkar, A.S., and Sane, N.K., (2005). Performance Assessment of HC- 290 as a Drop- In Substitute to HCFC-22 in a Window Air- Conditioner. International Journal of Refrigeration. 28, 594-604.

Chang, C.H. and Meroney. R.N. (2003). Concentration and Flow Distribution in Urban Street Canyons: Wind Tunnel and Computational Data. Journal of wind Engineering and Industrial Aerodynamics. 91 (9), 1141-1154.

Dossat, R.J. (1997). Principles of Refrigeration. 4th Edition. Prentice Hall, New Jersey, USA.

Dwyer, T. (2019). Ensuring Safe, Environmentally, Sensitive Refrigerants for Building Services Applications. CIBSE Journal. June 2019. 55-58

Ecometrica. (2011). Electricity- Specific Emission Factors for Grid Electricity. London, U.K.

Ener-save (2017). Northcutt Hydrocarbon Refrigerant Gas. http://dudamobile.ener- save.biz/#2765, assessed 01.12.2017

European Commission (EC). (2006). Directive 2006/40/EC of the European Parliament and of the Council of 17 May 2006 Relating to Emissions from Air Conditioning Systems in Motor Vehicles and Amending Council Directive 70/156/EEC. Official Journal of the European Union, 2006. L 161/12 of 14.6.2006.

European Commission (EC). (2014). Regulation no. 517, /2014 of the European Parliament and of the Council of 16 April 2014 on Fluorinated Gases and Repealing Regulation (EC) No. 842/2006. Official Journal of the European Union, 2014. L 150/195 of 20.5.2014.

Fatouh, M. and Kafafy, M.E., (2006). Assessment of Propane/Commercial Butane Mixtures as Possible Alternatives to R-134a in Domestic Refrigeration. Energy Conversion and Management. 47, 2644-2658.

German Federal Enterprise for International Cooperation (GIZ), (2014). Manufacture of Room Air Conditioners using Hydrocarbons as Replacement for Halogenated Refrigerants. https://www.giz.de/en/worldwide/16676.html, assessed 17.04.2014

Girodroux, F., Kusmierz, A. and Dahn, C.J. (2000). Determination of Critical Flammability Ratio (CFR) of Refrigerant Blends. Journal of Loss Prevention in the Process Industries. 13, 385-392.

Granryd, E. (2001). Hydrocarbons as Refrigerants- An Overview. International Journal of Refrigeration. 24, 15-24.

Greenpeace. (2004). Natural Refrigerants: The Solutions. Greenpeace International, Amsterdam, The Netherlands.

Halimic, E., Ross, D., Agnew, B., Anderson, A. and Potts, I. (2003). A Comparison of Operating Performance of Alternative Refrigerants. Applied Thermal Engineering. 23, 1441-1451.

He, M.G., Song, X.Z., Liu, H. and Zhang, Y. (2014). Application of Natural Propane and Propane/Isobutane in Large Capacity Chest Freezer. Applied Thermal Engineering. 70, 732-736.

197

Hwang, Y., Jin, D.H. and Rademacher, R. (2007). Comparison of R-290 and Two HFC Blends for Walk- In Refrigeration Systems. International Journal of Refrigeration. 30, 633-641.

HyChill. (2017). HyChill Refrigerants. http://hychill.com.au/ assessed 01.12.2017 IEC 60335-2-40, (2005). Specification for Safety of Household and Similar

Electrical Appliances. Safety. Particular Requirements for Electrical Heat Pumps, Air Conditioners and Dehumidifiers. IEC. Geneva, Switzerland. Joudi, K.A. and Al Amir, Q.R. (2014). Experimental Assessment of Residential Split

Type Air Conditioning Systems Using Alternative Refrigerants to R22 at High Ambient Temperature. Energy Conversion and Management. 86, 496- 506.

Jung, D., Seo, T. and Park, K.J. (2007). Performance of Alternative Refrigerants for Residential Air- Conditioning Applications. Applied Energy. 84, 985-991. Katz, D.L. and Lee. R.L., (1990). Natural Gas Engineering- Production and Storage.

McGraw-Hill, Singapore.

Kim, M.H., Lim, B.H. and Chu, E.S. (1998). The Performance Analysis of a Hydrocarbon Refrigerant R-600a in a Household Refrigerator/Freezer. KSME International Journal. 12(4), 753-760.

Langley, B.C., (1994). Refrigerant Management: The Recovery, Recycling and Reclaiming of CFCs. Delmar Publishers Inc. Albany, NY, USA.

Lee, Y.S. and Su, C.C. (2002). Experimental Studies of Isobutane (R-600a) as Refrigerant in Domestic Refrigeration System. Applied Thermal Engineering. 22, 507-519.

Lian, Y., Long, Z., Wang, L., Bu, X. and Li, H. (2013). Hydrocarbon Working Fluids for a Rankine Cycle Powered Vapor Compression Refrigeration System Using Low- grade Thermal Energy. Energy and Buildings.65, 167-172. Li, T. (2014). Indoor Leakage Test for safety of R290 Split Type Room Air-

Conditioner. International Journal of Refrigeration. 40, 380-389.

Li, Y.N., Tao, J.J., Han,Y.C., Han, X. and Qin, J. (2014). Numerical and Experimental Study on the Diffusion Property of Difluoromethane (HFC 32) in Leakage. Procedia Engineering. 71, 34-43.

Liu, Y., Li, Q., Zhang, H. M., Huang, H., Zhang, X., Li, Z. and Yao, W. (2013). Influencing Factors of Flammable Refrigerants Leaking in Building Air- Conditioning System. Procedia Engineering. 62, 648-654.

Linde. (2010). Natural Refrigerants- R 290 Refrigerant Grade Propane- High Quality Natural Refrigerant. Linde AG, Linde Gases Division, Pullach, Germany.

Linde. (2017). Linde Gas- Refrigerants. http://www.linde- gas.com/en/products_and_supply/refrigerants/index.html assessed 01.12.2017 Little, A.D. (2002). Global Comparative Analysis of HFC and Alternative Technologies for Refrigeration, Air Conditioning, Foam, Solvent, Aerosol Propellant and Fire protection Applications. Final Report to the Alliance for Responsible Atmospheric Policy. Cambridge, Massachusetts, USA.

Lorentzen, G. (1995). The Use of Natural Refrigerant: A Complete Solution to the CFC/HFC Predicament. International Journal of Refrigeration. 18(3), 190- 197.

M.S. ISO 5151, (2012). Non-Ducted Air Conditioners and Heat Pumps- Testing and Rating for Performance. Department of Standards Malaysia.

M.S. 930. (2010) – Code of Practice for the Installation of Fuel Gas Piping Systems and Appliances. Department of Standards Malaysia.

M.S. 830. (2013) – Code of Practice for the Storage, Handling and Transportation of LPG. Department of Standards Malaysia.

M.S. 2597. (2014) - Minimum Energy Performance Standards (MEPS) for Air Conditioners. Department of Standards Malaysia.

M.S. 2678. (2017). Flammable Refrigerant System- Code of Practice, Department of Standards Malaysia.

Majid, Z.A., Yaccob, Z., and Ahmad Khan, Y. (2002). Compatibility of Malaysian Liquefied Petroleum Gas (LPG) with Copper Pipe. Proceedings of GASEX 2002, 27-30th May 2002, Brunei Darussalam.

Malaysia Productivity Corporation (MPC). (2016). Oil and Gas Sector. http//www.mpc.gov.my/wp-content/uploads/2016/04/Chap2.pdf, accessed 23.07.2019

Malaysian Oxygen Berhad. (MOX), (2010). Infrastructure for Natural Refrigerants- Environmentally Friendly Solution from ‘The Linde Group’. HCFC Phase- out Management Plan (HPMP) National Stakeholders Workshop. Kuala Lumpur, November 2010.

199

Masson. N., Jomard. T., and Brouwers. C. (2014). Natural Refrigerants in Europe: The Drivers and Challenges for European Food Retailers. Shecco

Publications. 2014.

http://www.r744.com/files/1676_carrier_report_by_shecco.pdf, accessed 02.03.2016

Mc Linden, M.O., Lemmon, E.W. and Jacobson, R.T. (1998). Thermodynamic Properties for Alternative Refrigerants. International Journal of Refrigeration. 21(4), 322-338.

Mc Quiston, F.C. and Parker, J.D. (1994). Heating, Ventilating and Air Conditioning- Analysis and Design. 4th Edition. John Wiley & Sons, New York, USA.

Meyer, J.P. (1999). New Energy Efficient and Environmentally Safe Refrigerants in Domestic Refrigeration and Freezers. Domestic Use of Electrical Energy Conference. 1999. 124-127.

Ministry of Manpower Singapore (MOM). (2014). Letter on: Joint Circular on Safe Handling and Use of Hydrocarbon Refrigerants. 20th February 2014. Ministry of Manpower, Singapore.

Mohammad, W.S. and Jassim, A.O. (2014). Experimental and Theoretical Investigations of Propane/Butane and Propane/Isobutane Mixtures as an Alternative to R-1234a in a Domestic refrigerator. Engineering and Technology Journal. 32(5), 1266-1286.

Mohanraj, M., Jayaraj, S. and Muraleedharan, C. (2007). Improved Energy Efficiency for HFC134a Domestic Refrigerator Retrofitted with Hydrocarbon Mixture (HC290/HC600a) as Drop- In Substitute. Energy for Sustainable Development. 11(4), 29-33.

Mohanraj, M., Jayaraj, S., Muraleedharan, C. and Chandrasekar, P. (2009). Experimental Investigation of R-290/R-600a Mixture as an Alternative to R- 134a in a Domestic Refrigerator. International Journal of Thermal Sciences. 48, 1036-1042.

Molina, M.J. and Rowland, F.S. (1974). Stratospheric Sink for Chlorofluoromethanes: Chlorine Atom Catalysed Destruction of Ozone. Nature. 249, 810-812.

Nagaosa, R.S. (2014). A New Numerical Formulation of Gas Leakage and Spread into a Residential Space in Terms of Hazard Analysis. Journal of Hazardous Materials. 271, 266-274.

NIST, (2010) REFPROP version 9.0. National Institute of Standards and Technology, Department of Commerce, USA.

NIST, (2017) Fire Dynamics Simulator (FDS) version 6.5.3. Technical Reference Guide Volume 1: Mathematical Model. National Institute of Standards and Technology, Department of Commerce, USA.

Norman, C.S., DeCanio, S.J. and Fan, L. (2008). The Montreal Protocol at 20: Ongoing Opportunities for Integration with Climate Protection. Global Environmental Change.18, 330-340.

Padalkar, A.S., Mali, K.V. and Devotta, S. (2014). Simulated and Experimental Performance of Split Packaged Air Conditioner Using Refrigerant HC-290 as a Substitute for HCFC 22. Applied Thermal Engineering. 62, 277-284.

Palm, B., (2008). Hydrocarbons as Refrigerants in Small Heat Pump and Refrigeration Systems- A Review. International Journal of Refrigeration. 31, 552-563.

Park, K.J., Seo, T. and Jung, D. (2007). Performance of Alternative Refrigerants for Residential Air- Conditioning Applications. Applied Energy. 84, 985-991. Park, K.J. and Jung, D. (2007). Thermodynamic Performance of HCFC 22

Alternative Refrigerants for Residential Air- Conditioning Application. Energy and Buildings. 39, 675-680.

Park, K.J., Shim, Y.B. and Jung, D. (2009). A “Drop In” Refrigerant 431a for Replacing HCFC 22 in Residential Air Conditioners and Heat Pumps. Energy Conversion and Management. 50, 1671-1675.

Paroche, K. and Gupta, R.C. (2012). Performance Analysis of Reciprocating Compressor Using Eco- Friendly Refrigerants. International Journal of Mechanical, Automotive and Production Engineering. 2(9), 320-329.

Powell, R.L. (2002). CFC Phase-Out: Have We Met the Challenge? Journal of Fluorine Chemistry.114, 237-250.

Purkayastha, B. and Bansal, P.K. (1998). An Experimental Study on HC290 and a Commercial Liquefied Petroleum Gas (LPG) Mix as Suitable Replacements for HCFC 22. International Journal of Refrigeration. 21(1), 3-17.

201

Ramu, N.S., Kumar, P.S. and Mohanraj, M. (2014). Performance Assessment of R- 32/R-125/R-600a Mixtures as Possible Alternatives to R-22 in Compression Refrigeration Systems. International Journal of Mechanical and Mechatronics Engineering. 14(2), 12-22.

Rasti, M., Hatamipour, M.S., Aghamiri, S.F. and Tavakoli, M. (2012). Enhancement of Domestic Refrigerator’s Energy Efficiency Index Using a Hydrocarbon Mixture Refrigerant. Measurement. 45, 1807-1813.

Riffat, S.B., Alfonso, C.F., Oliveira, A.C. and Reay, D.A. (1996). Natural Refrigerants for Refrigeration and Air- Conditioning. Applied Thermal Engineering. 17(1), 33-42.

Rose, E. (2017) Cold Case- Refrigerants Overview. CIBSE Journal. May 2017, 39- 43.

Roy, R and Mandal, B.K. (2014). First Law and Second Law Analysis of Mechanical Vapour Compression Refrigeration System using Refrigerants CFC 12, R- 134a and R-290. International Journal of Current Engineering and Technology. 3, 191-195.

Sarbu, I (2014). A Review on Substitution Strategy of Non-Ecological Refrigerants from Vapour Compression-Based Refrigeration, Air-Conditioning and Heat Pump Systems. International Journal of Refrigeration. 46, 123-141 Sattar, M.A., Saidur, R. and Masjuki, H.H. (2008). Experimental Investigation on the

Performance of Domestic Refrigerator Using Isobutane and Mixture of Propane, Butane and Isobutane. Proceedings of the 1st International Conference of IET Brunei Darulsalam Network. Brunei Darulsalam.

Sekiya, A., Yamabe M., Tokuhashi, K., Hibino, Y., Imasu, R., and Okamoto, H. (2006). Evaluation and Selection of CFC Alternatives. Fluorine and The Environment, Volume 1, 33-87.

Shiels, V and Lyons, B. (2008). The Quality of Natural Refrigerants- The Importance of Specifying High Purity Products. BOC, The Priestley Centre, 10 Priestley Road, The Surrey Research Park, Guildford, Surrey GU2 7XY, U.K.

Singapore Civil Defence Force (SCDF). (2011). Letter on: Review on the Use of Hydrocarbon Refrigerant in Singapore. 6th December 2011. Ministry of

Singapore Civil Defence Force (SCDF). (2013). Letter on: Regulatory Requirements for the Usage of Flammable Refrigerant in Stand- Alone Commercial Refrigeration System in Singapore. 25th January 2013. Ministry of Home Affairs, Singapore.

SIRIM QAS. (2016). Air Conditioner: Energy Efficiency Test. http://www.sirim- qas.com.my/core-files/uploads/2016/AIR-CONDITIONER.pdf, accessed 15.09.2018

Teng, P.T., Mo, H.E., Lin, H., Tseng, Y.H., Liu, R.H. and Long, Y.F. (2012). Retrofit Assessment of Window Air- Conditioner. Applied Thermal Engineering. 32, 100-107.

Thangavel, P. and Somasundram, P. (2013). Part Load Performance Analysis of Vapour Compression Refrigeration System with Hydrocarbon Refrigerants. Journal of Scientific and Industrial Research. 72, 454-460.

The Linde Group (Linde) (2008), Natural Refrigerants- R 290 Refrigerant Grade Propane. Linde AG, Linde Gases Division, Pullach, Germany.

Trott, A.R. and Welch, T. (2000). Refrigeration and Air- Conditioning. 3rd Edition, Butterworth-Heinemann, U.K.,

United Nations (UN), (1987). Montreal Protocol on Substances that Deplete the Ozone Layer (with annex), UN Treaty Series, New York.

United Nations (UN), (1998). Kyoto Protocol to the United Nations Framework Convention on Climate Change, New York.

UNEP, (1992). The Copenhagen Amendment: The Amendment to the Montreal Protocol Agreed by the Fourth Meeting of the Parties (1992). http://www.unep.ch/ozone/Ratification_status/copenhagen_amendment.shtml assessed 03.04.2017

UNEP, (2001). Intergovernmental Panel on Climate Change (IPCC) – 3rd

Assessment Report (AR 3)

https://www.ipcc.ch/ipccreports/tar/wg1/pdf/WGI_TAR_full_report.pdf, accessed 30.11.2016

UNEP, (2007). Intergovernmental Panel on Climate Change (IPCC) – 4th

Assessment Report (AR 4)

https://www.ipcc.ch/publications_ipcc_fourth_assessment_report_synthesis_r eport.html, accessed 30.11.2016

203

UNEP, (2010). Report of the Refrigeration, Air- Conditioning and Heat Pumps - Technical Options Committee, 2010 Assessment Report.

https://unep.ch/ozone/Assessment_Panels/TEAP/Reports/RTOC/RTOC-Assessment- report-2010.pdf, accessed on 30.11.2016

UNEP, (2013). Intergovernmental Panel on Climate Change (IPCC) - 5th Assessment Report (AR 5) https://www.ipcc.ch/pdf, accessed 30.11.2016

UNEP, (2016), Frequently Asked Questions Relating to the Kigali Amendment to the Montreal Protocol. http://ec.europa.eu/clima/sites/clima/files/faq_kigali- amendment_en.pdf, accessed 03.04.2017

U.S, EPA, (2015), SNAP Report. www.epa.gov/ozone/snap/index.html, accessed, 26.09.2015.

Wang, S.K. (1993), Handbook of Air Conditioning and Refrigeration. Mc Graw-Hill, New York, USA.

Wang, Z., Yang, Z., Li, J., Ren, C., Lu, D., Wang, J., Zhang, X. and Wu, W. Research on the Flammability hazards of an Air Conditioner using Refrigerant R-290. International Journal of Refrigeration. 36, 1483-1494. Wu, J.H., Yang, L.D. and Hou, L. (2012). Experimental Performance Study of a

Small Wall Room Air- Conditioner Retrofitted with R-290and R-1270. International Journal of Refrigeration. 35, 1860-1868.

Wu, X., Hu, S. and Mo, S. (2013). Carbon Footprint Model for Evaluating the Global Warming Impact of Food Transport Refrigeration Systems. Journal of Cleaner Production. 54, 115-124.

Wongwises, S. and Chimres, N. (2005). Experimental Study of Hydrocarbon Mixtures to Replace HFC 134a in a Domestic Refrigerator. Energy Conversion and Management. 46, 85-100.

Yang, L.D., Wu, J.H. and Hou, J. (2012). Experimental Performance Study of a Small Wall Room Air Conditioner Retrofitted with R 290 and R 1270. International Journal of Refrigeration. 35, 1860-1868.

Yang, Z. and Wu, X. (2013). Retrofits and Options for Alternative of HCFC 22. Energy. 59, 1-21.

Yu, C.C. and Teng, T.P. (2014). Retrofit Assessment using Hydrocarbon Refrigerants, Applied Thermal Engineering. 66, 507-518.

Yu, J., Xu, Z. and Tian, G. (2010). A Thermodynamic Analysis of a Transcritical Cycle with Refrigerant Mixture R-32/R-290 for a Small Heat Pump Water Heater. Energy and Buildings. 42, 2431-2436.

Yvon, M. and Champassith, A. (2009). CFD Simulations of Atmospheric Gas Dispersion using Fire Dynamics Simulator (FDS). Journal of Loss Prevention in the Process Industries. 22 (3), 316-323

Zhang, W., Yang, Z., Li, J., Ren, C.X., Lu, D., Wang, J. and Wu, W. (2013). Research on the Flammability Hazards of an Air Conditioner using Refrigerant R-290. International Journal of Refrigeration. 36, 1483-1494.

Documento similar