3.2.5.  DETECTION  OF  PALYTOXINS  IN  OSTREOPSIS  CELLS  BY  LC-­‐MS/MS      

Extracts   of   the   natural   Ostreopsis   cells   samples,   prepared   as   previously   reported   for   the   ELISA,   were   analysed   by   LC-­‐MS/MS.   The   method   for   the   analysis   was   initially  optimized  as  explained  below.  

Chromatographic  separation  was  carried  out  using  an  Agilent  1290  Infinity  UHPLC   system   consisting   of   a   binary   pump,   a   high   performance   autosampler,   and   a   thermostated   column   compartment.   The   study   was   based   on   the   optimization   of     LC-­‐MS/MS   method   reported   by   Ciminiello   et   al.   (2008).   In   particular,   LC-­‐MS/MS   analyses   were   carried   out   using   a   3   µm   Gemini   C18   (150   x   2.00   mm)   column   (Phenomenex)   maintained   at   room   temperature   and   eluted   at   0.2   mL/min   with   water  (Eluent  A)  and  95%  acetronitile/water  (Eluent  B),  both  containing  30  mM   acetic   acid.   The   following   gradient   systems   were   also   proposed:   a   fast   gradient   elution   (20%   to   100%   B   over   10   minutes   and   hold   5   minutes),   which   allowed   elution  of  palytoxin  at  6.60  minutes,  and  a  slow  gradient  elution  (20%  to  50%  B   over  20  minutes,  50%  to  80%  B  over  10  minutes,  80%  to  100%  B  in  1  minute,  and   hold   5   minutes),   which   allowed   chromatographic   separation   between   palytoxin   and  ovatoxin-­‐a.  Mass  spectral  experiments  were  carried  out  with  LC-­‐MS  systems:  

an   Agilent   1100   LC   binary   system   coupled   to   a   PE-­‐SCIEX   API   2000   triple-­‐

quadrupole  MS  equipped  with  a  Turbospray  source.    

 

The   following   chromatographic   parameters   were   investigated   and   optimized:  

gradient,   acetic   acid   content,   flow.   Diluted   samples   and   standards   (10   µL)   were   injected   without   any   further   clean-­‐up.   The   samples   in   the   autosampler   were   cooled   to   7ºC.   MS   detection   was   performed   using   an   Agilent   Technologies   6460   TripleQuad   LC/MS   triple   quadrupole   mass   spectrometer   (Agilent   Technologies;  

Santa  Clara,  USA).    

On  the  other  hand  the  following  key  parameters  were  also  optimized:  

 

- Fragmentor  (V)  

- Collision  Energy  (50  eV)   - Gas  Temperature  (300  °C)   - Flow  (L/min)  

  87   - Nebulizer  (psi)  

- Sheath  Gas  Temperature  (°C)   - Sheath  Gas  Flow  (L/min)   - Capillary  Voltage  (5500  V)   - Noozle  Voltage  (V)  

   

MS  detection  was  carried  out  in  positive  ion  mode.  The  Full  SCAN  mode  method   was   carried   out   using   a   Fragmentor   of   100   V   and   in   the   range   m/z   700-­‐1500.  

Selected  Ion  Monitoring  (SIM)  was  carried  out  selecting  the  327.1  ion  transition,   with   a   Fragmentator   of   380   V   and   a   Dwell   time   of   200   ms.   This   transition   corresponds  to  the  common  fragment,  to  the  shared  A  moiety  by  all  the  toxins  of   the  PLTX  group.  

Ciminiello   et   al.   (2008)   carried   out   the   LC-­‐MS   analysis   in   Multiple   Reaction   Monitoring  (MRM)  mode  by  monitoring  the  representative  transitions  m/z  1340.7  

—>  327.1  (Declustering  Potential  of  8  V),  1331.7  —>  327.1  (DP  =  8  V)  and  906.1  —

>   327.1   (DP   =   50V)   for   ovatoxin-­‐a.   The   transitions   m/z   1340.7   —>   327.1   and   1324.7  —>  327.1,  were  used  for  quantitation  of  putative  palytoxin  and  ovatoxin-­‐a,   respectively.    

For   the   confirmation   of   the   quantitative   results   obtained   for   ovatoxin-­‐a,   Ciminiello’s  group  used  the  Selected  Ion  Monitoring  (SIM).  The  following  ions  were   monitored  for  ovatoxin-­‐a  m/z  890.1,  896.1,  1297.7,  1306.7,  1315.7,  1324.7,  1335.7,   1343.7  whereas  the  following  ions  were  monitored  for  palytoxin  m/z  906.1,  901.1,   1313.7,  1322.7,  1331.7,  1340.7,  1351.7,  1359.7.    

After  the  optimization  of  all  the  parameters  for  the  LC-­‐MS/MS  analysis  and  when   the   calibration   curve   was   done   basing   the   experiments   in   PLTX   standard,   three   samples   from   the   South   Coast   of   Portugal   were   analysed   and   quantified.   These   samples   were   gently   yielded   by   Dr.   Pedro   Reis   from   the   IPIMAR   of   Lisbon   (Portugal).    

Quantitative  results  were  obtained  by  direct  comparison  of  peak  areas  to  standard   solutions  of  palytoxin  at  similar  concentration  injected  in  the  same  experimental   conditions.  

   

  88   3.2.5.1.  Derivatization  

Strata-­‐X  Polymeric  Solid  Phase  Extraction  Sorbents  (SPE)(Fig.  33)  reversed  phase   sorbent  retains  analytes  by  hydrophobic  interaction  and  has  H-­‐  and  π-­‐π  bonding   capabilities  for  enhanced  retention  of  polar  and  aromatic  analytes.  The  enhanced   retention   mechanism   of   Strata-­‐X   SPE   can   be   very   powerful   for   applications   that   require   simultaneous   extraction   of   polar   analytes   and   non-­‐polar   parent   compounds.  The  strong  retention  mechanisms  of  Strata-­‐X  SPE  allow  for  aggressive   washing   with   organic   solvents   to   remove   impurities   without   breakthrough   of   analyte.  Strata-­‐X  SPE  offers  reversed  phase  selectivity  without  the  limitations  such   as  improper  clean-­‐up,  breakthrough,  pH  considerations,  and  method  development   concerns.  Strata-­‐X  Polymeric  Solid  Phase  Extraction  Sorbents  (SPE)  provides  clean   samples  and  high  recoveries  for  polar  and  non-­‐polar  compounds.  

   

Figure  33:  Strata-­‐X  stationary  phase.    

   

 

The   derivatization   of   palytoxin   was   carried   out   as   reported   by   Selwood   et   al.  

(2012).  In  particular,  palytoxin  and  algal  extracts  were  loaded  onto  60  mg  Strata-­‐X   SPE  cartridge  (Phenomenex),  pre-­‐conditioned  with  3  mL  methanol  followed  by  3   mL  Milli-­‐Q  water.  The  sample  (1  mL)  or  standard  was  loaded  in  the  Strata-­‐X  SPE   column  drop  by  drop  in  order  that  the  molecule  was  retained  in  the  column.  The   column  was  washed  with  2  mL  methanol:water  (2:3  v/v)  followed  by  2  mL  Milli-­‐Q   water.   The   sample   or   standard   was   then   oxidized   on   the   SPE   column   by   passing   through   2   mL   of   50   mM   periodic   acid   at   ca   1   mL/min.   The   column   was   washed   with  2  mL  Milli-­‐Q  water  and  the  oxidation  products  were  then  eluted  using  3  mL  of   methanol-­‐water   (3:2  v/v)   containing   0.1   %  v/v   acetic   acid.   The   eluent   was   filtered   using   0.22   µm   Millipore   filter   and   transferred   into   a   glass   vial   for   LC-­‐MS/MS   analysis.   Oxidation   of   palytoxins   or   ovatoxins   using   periodic   acid   generates   two-­‐

  89  

nitrogen   containing   aldehyde   fragments;   an   amino   aldehyde   common   to   these   toxins,  and  an  amide  aldehyde  that  may  vary  depending  on  toxin  type.  

A  vacuum  system  was  used  to  load  the  reagents  and  the  samples,  if  needed.  

The  MRM  mode  analysis  after  oxidation  step  was  carried  out  basing  in  two  main   molecule  fragments  obtained  after  the  derivatization  of  the  toxin.  These  fragments   were   m/z   300.2   and   343.2,   corresponding   to   the   amino   aldehyde   and   amide   aldehyde,  respectively,  and  wee  selected  as  Precursor  Ions.    

For   each   one   of   them,   two   transitions   were   selected   in   order   to   have   one   qualitative   and   other   quantitative   transition,   as   Product   Ions.   For   the   amino   aldehyde  fragment  (m/z  300.2),  the  300.2  —>  107.1  (q)  and  300.2  —>  221.2  (Q)   were   selected.   On   the   other   hand,   342.2   —>   123.3   and   342.2   —>   76.1   were   the   selected  transitions  for  the  amide  aldehyde  fragment  (m/z  343.2).  

     

3.2.6.  EVALUATION  OF  PALYTOXIN  CYTOTOXICITY  ON  CARDIOMYOCYTES    

3.2.6.1.  Primary  cultures  of  cardiomyocytes  

Rat  cardiomyocytes  were  isolated  as  described  by  Harary  and  Farley  (1963),  with   modifications.  Experiments  complied  with  the  Italian  Decree  n.  116/1992  s  well  as   the  EU  Directive  2010/63/EU)  and  the  European  Convention  ETS  123.    

Briefly,   1-­‐to   3-­‐day-­‐old   Wistar   rats,   obtained   from   a   local   conventional   breeding   colony,   were   euthanized   by   decapitation   and   allowed   to   bleed.   The   hearts   were   aseptically  removed  by  surgical  dissection,  taking  ventricles  only,  placed  in  a  Petri   dish   containing   ice-­‐cold   Ca2+   and   Mg2+-­‐free   Hank’s   balanced   salt   solution   and   washed  thoroughly  to  remove  excess  blood.  The  hearts  were  minced  into  1  mm3   fragments,  Hank’s  solution  was  replaced  by  10  mL  of  trypsin  solution  (0.1  %  w/v),   and  the  preparation  was  transferred  to  a  trypsinator  at  32  °C-­‐35  °C  with  a  stirring   rate   of   150-­‐200   rpm   for   15   minutes.   Fragments   were   allowed   to   settle,   and   the   supernatant  was  removed  after  each  trypsinization.    

The  first  trypsinization,  containing  mainly  cell  debris,  red  blood  cells,  pericardial   and   endothelial   cells,   was   discarded.   Cells   from   subsequent   trypsinizations   were   collected  in  50  mL  sterile  Falcon  tubes,  20  mL  of  complete  growth  medium  (Ham’s  