Three control units belong to the crane control: If one control unit fails, theCrane control displaydisplays an error message as in the diagram opposite:

SYSTEM is in the second line. In the third line you will find UNIT 0, 1 or 2, for the control units on the connections 0 to 2.

The number code in the fourth line is of secondary importance.

The following table shows which crane functions are out of operation when the control unit fails on a connection:

Error message on the display

Error and effect

Action

UNIT 0:

Control unit on

connection 0 defective, function of the crane control, main hoist and auxiliary hoist blocked.

The truck crane can be rigged by changing the connection lines on another control unit in on-the-road mode;

Changing the connections in the control units, p. 16-66.

UNIT 1:

Control unit on

connection 1 defective, telescoping gear, derricking gear, counterweight lifting cylinder and locking pins, superstructure lock and tilt crane cab and, with additional equipment, derricking of lattice extension blocked.

UNIT 2:

Control unit on

connection 2 defective, slewing gear and fast speeds blocked.

UNIT 1: 0 0 0 0 0 0 1 0

ERROR MESSAGE

STATUS: 0 0 0 0 0 0 1 0 SYSTEM

If there is an error message about drive units it will appear in the second line of the affec-ted drive unit (e. g. the telescoping gear).

You also get different entries and number codes in the two bottom lines.

+

If you have already acknowledged the error message, you can call up the Display statesmenu and then

>

thememory error submenu and view the error message there again;

Display states menu - Memory error submenu, p. 13-82.

In the first line you will see the message ERROR MEMORY and the number of the error (e. g. 3). The displays in the other lines are the same as with the error message.

The messages here are only an example which will be dealt with at the end of the following sections.

Using the messages in the bottom two lines you can

– determine the part on which the error occurred;

Determining defective part, p. 16-61.

– determine the area of the error, depending on the detected part;

Determining error area, p. 16-62.

– locate more precisely the cause of the error;

Error causes and effects, p. 16-63.

H

In the following sections you will find more information on the displayed errors. If, in the sections, you are asked to contact GROVE Product Sup-port, please note down the number code beforehand and have it ready.

Ö

When you have noted down the error codes you can acknowledge the error message. To do this press theENTERkey.

After you have carried out the acknowledgement process, the display shows the indication which was displayed before the error message.

TELESCOPING SYSTEM ERROR MESSAGE

STATUS: 0 0 0 0 0 0 0 1 J3502: 0 1 0 0 0 0 0 0

MEMORY ERROR TELESCOPING SYSTEM J3502: 0 1 0 0 0 0 0 0

STATUS: 0 0 0 0 0 1 0 0

3

18.03.1999

Determining defective part

The first message in the third line of the display describes the defective part (e. g. Y2301). The following table shows all the possible messages and their meaning.

Message Error Further troubleshooting

J3501

Error on a control lever

Determine cause of error;

Error causes and effects, p. 16-63.

J3502

A3502 Error on length indicator

A100

Error with the

communication with the SLI

ECOS Logic error detected by crane control

Other message (e. g. Y2301)

Error on another part (valve, digital input, pressure sensor)

Determine error area;

Determining error area, p. 16-62.

Example

In the display used as an example there is the message Y2301; according to the table there is an error on a part whereby you must first mine the area of the error before you can deter-mine the cause of the error.

MEMORY ERROR TELESCOPING GEAR Y2301: 0 0 0 0 0 0 0 1

STATUS: 0 0 0 0 0 1 0 0

3

The area where the error is is shown by the number code in the last line behind STATUS (e. g. 0 0 0 0 0 1 0 0 ). The following table shows possible number codes and the corresponding areas.

Number code Error in area Further troubleshooting 0 0 0 0 0 0 0 1 Control lever

Determine cause of error in the affected area;

Error causes and effects, p. 16-63.

0 0 0 0 0 0 1 0 Digital input 0 0 0 0 0 1 0 0 Output

0 0 0 0 1 0 0 0 Analogue input

0 0 0 1 0 0 0 0

CAN-Bus (always displayed together with ECOS, A100 or A3502) 1 0 0 0 0 0 0 0 ECOS (also displayed as

a part)

Example

In the display used as an example the number code 0 0 0 0 0 0 0 1 is in the last line.

The table assigns this number code an error in the output area.

The “output” area is in the table in the next section. Here you can determine the cause of the error in this area.

MEMORY ERROR TELESCOPING GEAR Y2301: 0 0 0 0 0 0 0 1

STATUS: 0 0 0 0 0 1 0 0

3

18.03.1999

Error causes and effects

Once you have determined the defective part or the area where the error is, the table will give you more information on the cause and the effects.

In this table the number code in the third line behind the part (e. g. 0 0 0 0 0 0 0 1 behind Y 2301) is decisive.

Defective part or area

Number code in the third line on the display

Cause of error Effect/

Remedy

defective Control lever emergency

reception Inform GROVE Product Support 0 0 0 0 0 0 1 0 Hardware error

Communica-tion with SLI A100

0 0 0 0 0 0 01

No data

reception from SLI

When there is no display on the SLI, check fuse SI13;

Telescoping error messages p.16-65

Digital input 0 0 0 0 0 0 0 1 Line breakage/

24V short Inform GROVE Product Support 0 0 0 0 0 0 1 0 Earth contact

part or area

the third line on the display

Remedy

Output

0 0 0 0 0 0 0 1 Line breakage/

24V short

Inform GROVE Product Support 0 0 0 0 0 0 1 0 Earth contact

0 0 0 0 0 1 0 0 Line breakage 0 0 0 0 1 0 0 0 Output

Low resistance 0 0 0 1 0 0 0 0 Output

High resistance Analogue

input

0 0 0 0 0 0 0 1 24V short

Notify GROVE Product Support 0 0 0 0 0 0 1 0 Earth contact/

line breakage

Example

In the display used as an example the number code 0 0 0 0 0 0 0 1 is in the third line.

In the previous section we determined that the er-ror was in the output area.

According to the table this number code means that there is a Line breakage or a 24V short.

In this case you must inform GROVE Product Support and have the supply line checked.

MEMORY ERROR TELESCOPING GEAR Y2301: 0 0 0 0 0 0 0 1

STATUS: 0 0 0 0 0 1 0 0

3

18.03.1999