HydroTest

Yield Min Yield Ultimate Liters Liters

O . D .

(mm) Nominal

Weight K g / m

TUBE LOAD BODY (Newtons)

INTERNAL PRESSURE (kPa)

TORSIONAL YIELD

( N - m )

INTERNAL CAPACITY per meter

EXTERNAL DISPLACEMENT

per meter w/ min.

Wall

TUBING AREA (sq. cm)

Internal Min

PRECISION

TUBE TECHNOLOGY

Tel. 281-458-2883 Fax. 281-458-2886

Email: [email protected]

O . D . (110™ Metric Data Tabloid Rev.003 3/99) Test pressure value equals 90% of internal yield pressure rating. Maximum working pressure is a function of tube condition and is determined by user.

* Available as continuously milled tubing (CM™) or conventional butt-welded tubing sections (W™). All data is for new tubing at minimum strength.

Other sizes and wall thicknesses available on request. See individual size sheets for additional wall thicknesses.

O . D .

1"

COIL TUBING DATA

PRECISION

TUBE TECHNOLOGY

HS-110 - 1.000 - Rev.003 3/99

Available Grades:

NOTE: ABOVE DATA IS FOR NEW TUBING AT SPECIFIED MINIMUM STRENGTHS.

Houston, Texas

Telephone: (281) 458-2883 Fax: (281) 458-2886

1 . 0 0 0 0 . 1 0 9 0.104 0.782 1.040 33,000 35,100 19,700 21,900

0.293 0.493 618 684

1 . 0 0 0 0.104 24.95 0.59

O . D . Specified

Wall Minimum

TUBING AREA (sq. in.) DIMENSIONS

(Inches)

Internal Min.

w/ Wall Min.

TORSIONAL YIELD (ft. / lbs.) Yield Ultimate

INTERNAL CAPACITY per 1000 ft.

Gallons Barrels Gallons Barrels EXTERNAL DISPLACEMENT

per 1000 ft.

40.80 0.97

O . D . Specified

Wall Specified

Wall Minimum

I . D . Calculated DIMENSIONS

(Inches) Nominal

Weight Lbs. / ft.

TUBE BODY LOAD ( L b s . )

Yield Minimum

Tensile Minimum

INTERNAL PRESSURE (psi) HydroTest

9 0 %

Internal Yield Min

Torque Values Calculated Using Minimum Wall Thickness and Minimum Yield Strength.

Other sizes/wall thickness available on request.

Tube Body Load: Yield & Tensile Minimum calculated on Specified Wall.

Hydro Test: Test Pressure Value is 90% of the Minimum Internal Yield Pressure Rating.

Internal Yield: Internal Pressure to cause yielding using Minimum Yield Strength and Minimum Wall Thickness.

Maximum Working Pressure is a function of tube condition and is determined by the user.

HS-110™ CM™

(CONTINUOUSLY-MILLED TUBING)

O . D .

1 -1/4"

COIL TUBING DATA

PRECISION

TUBE TECHNOLOGY

HS-110 - 1.250 - Rev.003 3/99

NOTE: ABOVE DATA IS FOR NEW TUBING AT SPECIFIED MINIMUM STRENGTHS.

Houston, Texas

Telephone: (281) 458-2883 Fax: (281) 458-2886 1 . 2 5 0

1 . 2 5 0 1 . 2 5 0 1 . 2 5 0 1 . 2 5 0 1 . 2 5 0 1 . 2 5 0

0 . 1 0 9 0 . 1 1 6 0 . 1 2 5 0 . 1 3 4 0 . 1 4 5 0 . 1 5 6 0 . 1 7 5

0.104 0.111 0.118 0.128 0.138 0.148 0.167

1.032 1.018 1.000 0.982 0.960 0.938 0.900

1.332 1.408 1.506 1.601 1.715 1.827 2.014

42,200 44,600 47,700 50,700 54,400 57,900 63,800

44,900 47,500 50,800 54,000 57,900 61,700 68,000

17,700 18,800 19,900 21,500 23,100 24,700 27,600 15,900

16,900 17,900 19,400 20,800 22,200 24,800

0.374 0.397 0.420 0.451 0.482 0.512 0.568

0.853 0.830 0.808 0.776 0.745 0.715 0.659

1,030 1,081 1,129 1,195 1,257 1,316 1,417

1,117 1,178 1,238 1,320 1,399 1,475 1,610 1 . 2 5 0

1 . 2 5 0 1 . 2 5 0 1 . 2 5 0 1 . 2 5 0 1 . 2 5 0 1 . 2 5 0

0.104 0.111 0.118 0.128 0.138 0.148 0.167

43.45 42.28 40.80 39.34 37.60 35.90 33.05

1.03 1.01 0.97 0.94 0.90 0.85 0.79

O . D . Specified

Wall Minimum

TUBING AREA (sq. in.) DIMENSIONS

(Inches)

Internal Min.

w/ Wall Min.

TORSIONAL YIELD (ft. / lbs.) Yield Ultimate

INTERNAL CAPACITY per 1000 ft.

Gallons Barrels Gallons Barrels EXTERNAL DISPLACEMENT

per 1000 ft.

63.75 63.75 63.75 63.75 63.75 63.75 63.75

1.52 1.52 1.52 1.52 1.52 1.52 1.52

Available Grades:

O . D . Specified

Wall Specified

Wall Minimum

I . D . Calculated DIMENSIONS

(Inches) Nominal

Weight Lbs. / ft.

TUBE BODY LOAD ( L b s . )

Yield Minimum

Tensile Minimum

INTERNAL PRESSURE (psi) HydroTest

9 0 %

Internal Yield Min

Torque Values Calculated Using Minimum Wall Thickness and Minimum Yield Strength.

Other sizes/wall thickness available on request.

Tube Body Load: Yield & Tensile Minimum calculated on Specified Wall.

Hydro Test: Test Pressure Value is 90% of the Minimum Internal Yield Pressure Rating.

Internal Yield: Internal Pressure to cause yielding using Minimum Yield Strength and Minimum Wall Thickness.

Maximum Working Pressure is a function of tube condition and is determined by the user.

HS-110™ CM™

(CONTINUOUSLY-MILLED TUBING)

O . D .

1 -1/2"

COIL TUBING DATA

PRECISION

TUBE TECHNOLOGY

HS-110 - 1.500 - Rev.003 3/99

Available Grades:

NOTE: ABOVE DATA IS FOR NEW TUBING AT SPECIFIED MINIMUM STRENGTHS.

Houston, Texas

Telephone: (281) 458-2883 Fax: (281) 458-2886 1 . 5 0 0

TUBING AREA (sq. in.) Yield Ultimate

INTERNAL CAPACITY per 1000 ft.

Gallons Barrels Gallons Barrels EXTERNAL DISPLACEMENT

per 1000 ft.

91.80

(Inches) Nominal

Weight Lbs. / ft.

TUBE BODY LOAD ( L b s . ) PRESSURE (psi) HydroTest

9 0 %

Internal Yield Min

Torque Values Calculated Using Minimum Wall Thickness and Minimum Yield Strength.

Other sizes/wall thickness available on request.

Tube Body Load: Yield & Tensile Minimum calculated on Specified Wall.

Hydro Test: Test Pressure Value is 90% of the Minimum Internal Yield Pressure Rating.

Internal Yield: Internal Pressure to cause yielding using Minimum Yield Strength and Minimum Wall Thickness.

Maximum Working Pressure is a function of tube condition and is determined by the user.

HS-110™ CM™

(CONTINUOUSLY-MILLED TUBING)

O . D .

1 -3/4"

COIL TUBING DATA

PRECISION

TUBE TECHNOLOGY

HS-110 - 1.750 - Rev.003 3/99

NOTE: ABOVE DATA IS FOR NEW TUBING AT SPECIFIED MINIMUM STRENGTHS.

Houston, Texas

Telephone: (281) 458-2883 Fax: (281) 458-2886 1 . 7 5 0

TUBING AREA (sq. in.) Yield Ultimate

INTERNAL CAPACITY per 1000 ft.

Gallons Barrels Gallons Barrels EXTERNAL DISPLACEMENT

per 1000 ft.

124.95

Available Grades:

O . D .

(Inches) Nominal

Weight Lbs. / ft.

TUBE BODY LOAD ( L b s . ) PRESSURE (psi) HydroTest

9 0 %

Internal Yield Min

Torque Values Calculated Using Minimum Wall Thickness and Minimum Yield Strength.

Other sizes/wall thickness available on request.

Tube Body Load: Yield & Tensile Minimum calculated on Specified Wall.

Hydro Test: Test Pressure Value is 90% of the Minimum Internal Yield Pressure Rating.

Internal Yield: Internal Pressure to cause yielding using Minimum Yield Strength and Minimum Wall Thickness.

Maximum Working Pressure is a function of tube condition and is determined by the user.

HS-110™ CM™

(CONTINUOUSLY-MILLED TUBING)

O . D .

2"

COIL TUBING DATA

PRECISION

TUBE TECHNOLOGY

HS-110 - 2.000 - Rev.003 3/99

Available Grades:

NOTE: ABOVE DATA IS FOR NEW TUBING AT SPECIFIED MINIMUM STRENGTHS.

Houston, Texas

Telephone: (281) 458-2883 Fax: (281) 458-2886 2 . 0 0 0

TUBING AREA (sq. in.) Yield Ultimate

INTERNAL CAPACITY per 1000 ft.

Gallons Barrels Gallons Barrels EXTERNAL DISPLACEMENT

per 1000 ft.

163.20

(Inches) Nominal

Weight Lbs. / ft.

TUBE BODY LOAD ( L b s . ) PRESSURE (psi) HydroTest

9 0 %

Internal Yield Min

Torque Values Calculated Using Minimum Wall Thickness and Minimum Yield Strength.

Other sizes/wall thickness available on request.

Tube Body Load: Yield & Tensile Minimum calculated on Specified Wall.

Hydro Test: Test Pressure Value is 90% of the Minimum Internal Yield Pressure Rating.

Internal Yield: Internal Pressure to cause yielding using Minimum Yield Strength and Minimum Wall Thickness.

Maximum Working Pressure is a function of tube condition and is determined by the user.

HS-110™ CM™

(CONTINUOUSLY-MILLED TUBING)

O . D .

2 -3/8"

COIL TUBING DATA

PRECISION

TUBE TECHNOLOGY

HS-110 - 2.375 - Rev.003 3/99

NOTE: ABOVE DATA IS FOR NEW TUBING AT SPECIFIED MINIMUM STRENGTHS.

Houston, Texas

Telephone: (281) 458-2883 Fax: (281) 458-2886 2 . 3 7 5

2 . 3 7 5 2 . 3 7 5 2 . 3 7 5 2 . 3 7 5 2 . 3 7 5

0 . 1 2 5 0 . 1 3 4 0 . 1 4 5 0 . 1 5 6 0 . 1 7 5 0 . 1 9 0

0.118 0.128 0.138 0.148 0.167 0.180

2.125 2.107 2.085 2.063 2.025 1.995

3.011 3.215 3.462 3.706 4.122 4.445

95,400 101,900 109,700 117,500 130,600 140,900

101,600 108,500 116,800 125,100 139,100 150,000

10,700 11,600 12,400 13,300 15,000 16,100 9,600

10,400 11,200 12,000 13,500 14,500

0.837 0.904 0.970 1.035 1.158 1.241

3.593 3.527 3.460 3.395 3.272 3.189

4,672 5,004 5,326 5,639 6,210 6,582

4,908 5,277 5,640 5,996 6,654 7,090 2 . 3 7 5

2 . 3 7 5 2 . 3 7 5 2 . 3 7 5 2 . 3 7 5 2 . 3 7 5

0.118 0.128 0.138 0.148 0.167 0.180

184.24 181.13 177.37 173.64 167.31 162.38

4.39 4.31 4.22 4.13 3.98 3.87

O . D . Specified

Wall Minimum

TUBING AREA (sq. in.) DIMENSIONS

(Inches)

Internal Min.

w/ Wall Min.

TORSIONAL YIELD (ft. / lbs.) Yield Ultimate

INTERNAL CAPACITY per 1000 ft.

Gallons Barrels Gallons Barrels EXTERNAL DISPLACEMENT

per 1000 ft.

230.14 230.14 230.14 230.14 230.14 230.14

5.48 5.48 5.48 5.48 5.48 5.48

Available Grades:

O . D . Specified

Wall Specified

Wall Minimum

I . D . Calculated DIMENSIONS

(Inches) Nominal

Weight Lbs. / ft.

TUBE BODY LOAD ( L b s . )

Yield Minimum

Tensile Minimum

INTERNAL PRESSURE (psi) HydroTest

9 0 %

Internal Yield Min

Torque Values Calculated Using Minimum Wall Thickness and Minimum Yield Strength.

Other sizes/wall thickness available on request.

Tube Body Load: Yield & Tensile Minimum calculated on Specified Wall.

Hydro Test: Test Pressure Value is 90% of the Minimum Internal Yield Pressure Rating.

Internal Yield: Internal Pressure to cause yielding using Minimum Yield Strength and Minimum Wall Thickness.

Maximum Working Pressure is a function of tube condition and is determined by the user.

HS-110™ CM™

(CONTINUOUSLY-MILLED TUBING)

O . D .

2 -5/8"

COIL TUBING DATA

PRECISION

TUBE TECHNOLOGY

HS-110 - 2.625 - Rev.003 3/99

Available Grades:

NOTE: ABOVE DATA IS FOR NEW TUBING AT SPECIFIED MINIMUM STRENGTHS.

Houston, Texas

Telephone: (281) 458-2883 Fax: (281) 458-2886 2 . 6 2 5

2 . 6 2 5 2 . 6 2 5 2 . 6 2 5 2 . 6 2 5

0 . 1 3 4 0 . 1 4 5 0 . 1 5 6 0 . 1 7 5 0 . 1 9 0

0.128 0.138 0.148 0.167 0.180

2.357 2.335 2.313 2.275 2.245

3.574 3.850 4.124 4.590 4.953

113,300 122,000 130,700 145,500 157,000

120,600 129,900 139,200 154,900 167,100

10,500 11,300 12,100 13,600 14,600 9,400

10,100 10,900 12,200 13,200

1.004 1.078 1.152 1.290 1.383

4.408 4.334 4.260 4.122 4.029

6,209 6,617 7,014 7,742 8,220

6,516 6,970 7,416 8,243 8,793 2 . 6 2 5

2 . 6 2 5 2 . 6 2 5 2 . 6 2 5 2 . 6 2 5

0.128 0.138 0.148 0.167 0.180

226.66 222.45 218.28 211.17 205.63

5.40 5.30 5.20 5.03 4.90

O . D . Specified

Wall Minimum

TUBING AREA (sq. in.) DIMENSIONS

(Inches)

Internal Min.

w/ Wall Min.

TORSIONAL YIELD (ft. / lbs.) Yield Ultimate

INTERNAL CAPACITY per 1000 ft.

Gallons Barrels Gallons Barrels EXTERNAL DISPLACEMENT

per 1000 ft.

281.14 281.14 281.14 281.14 281.14

6.69 6.69 6.69 6.69 6.69

O . D . Specified

Wall Specified

Wall Minimum

I . D . Calculated DIMENSIONS

(Inches) Nominal

Weight Lbs. / ft.

TUBE BODY LOAD ( L b s . )

Yield Minimum

Tensile Minimum

INTERNAL PRESSURE (psi) HydroTest

9 0 %

Internal Yield Min

Torque Values Calculated Using Minimum Wall Thickness and Minimum Yield Strength.

Other sizes/wall thickness available on request.

Tube Body Load: Yield & Tensile Minimum calculated on Specified Wall.

Hydro Test: Test Pressure Value is 90% of the Minimum Internal Yield Pressure Rating.

Internal Yield: Internal Pressure to cause yielding using Minimum Yield Strength and Minimum Wall Thickness.

Maximum Working Pressure is a function of tube condition and is determined by the user.

HS-110™ CM™

(CONTINUOUSLY-MILLED TUBING)

O . D .

2 -7/8"

COIL TUBING DATA

PRECISION

TUBE TECHNOLOGY

HS-110 - 2.875 - Rev.003 3/99

NOTE: ABOVE DATA IS FOR NEW TUBING AT SPECIFIED MINIMUM STRENGTHS.

Houston, Texas

Telephone: (281) 458-2883 Fax: (281) 458-2886 2 . 8 7 5

2 . 8 7 5 2 . 8 7 5

0 . 1 5 6 0 . 1 7 5 0 . 1 9 0

0.148 0.167 0.180

2.563 2.525 2.495

4.541 5.059 5.462

143,900 160,300 173,100

153,200 170,700 184,300

11,000 12,400 13,400 9,900

11,200 12,100

1.268 1.421 1.524

5.224 5.071 4.968

8,541 9,445 10,041

8,987 10,002 10,680 2 . 8 7 5

2 . 8 7 5 2 . 8 7 5

0.148 0.167 0.180

268.01 260.12 253.98

6.38 6.19 6.05

O . D . Specified

Wall Minimum

TUBING AREA (sq. in.) DIMENSIONS

(Inches)

Internal Min.

w/ Wall Min.

TORSIONAL YIELD (ft. / lbs.) Yield Ultimate

INTERNAL CAPACITY per 1000 ft.

Gallons Barrels Gallons Barrels EXTERNAL DISPLACEMENT

per 1000 ft.

337.24 337.24 337.24

8.03 8.03 8.03

Available Grades:

O . D . Specified

Wall Specified

Wall Minimum

I . D . Calculated DIMENSIONS

(Inches) Nominal

Weight Lbs. / ft.

TUBE BODY LOAD ( L b s . )

Yield Minimum

Tensile Minimum

INTERNAL PRESSURE (psi) HydroTest

9 0 %

Internal Yield Min

Torque Values Calculated Using Minimum Wall Thickness and Minimum Yield Strength.

Other sizes/wall thickness available on request.

Tube Body Load: Yield & Tensile Minimum calculated on Specified Wall.

Hydro Test: Test Pressure Value is 90% of the Minimum Internal Yield Pressure Rating.

Internal Yield: Internal Pressure to cause yielding using Minimum Yield Strength and Minimum Wall Thickness.

Maximum Working Pressure is a function of tube condition and is determined by the user.

HS-110™ CM™

(CONTINUOUSLY-MILLED TUBING)

O . D .

3 -1/2"

COIL TUBING DATA

PRECISION

TUBE TECHNOLOGY

HS-110 - 3.500 - Rev.003 3/99

Available Grades:

NOTE: ABOVE DATA IS FOR NEW TUBING AT SPECIFIED MINIMUM STRENGTHS.

Houston, Texas

Telephone: (281) 458-2883 Fax: (281) 458-2886 3 . 5 0 0

3 . 5 0 0

0 . 1 7 5 0 . 1 9 0

0.167 0.180

3.150 3.120

6.230 6.733

197,400 213,400

210,200 227,200

10,200 11,000 9,200

9,900

1.749 1.877

7.872 7.744

14,447 15,397

15,146 16,200 3 . 5 0 0

3 . 5 0 0

0.167 0.180

404.84 397.16

9.64 9.46

O . D . Specified

Wall Minimum

TUBING AREA (sq. in.) DIMENSIONS

(Inches)

Internal Min.

w/ Wall Min.

TORSIONAL YIELD (ft. / lbs.) Yield Ultimate

INTERNAL CAPACITY per 1000 ft.

Gallons Barrels Gallons Barrels EXTERNAL DISPLACEMENT

per 1000 ft.

499.80 499.80

11.90 11.90

O . D . Specified

Wall Specified

Wall Minimum

I . D . Calculated DIMENSIONS

(Inches) Nominal

Weight Lbs. / ft.

TUBE BODY LOAD ( L b s . )

Yield Minimum

Tensile Minimum

INTERNAL PRESSURE (psi) HydroTest

9 0 %

Internal Yield Min

Torque Values Calculated Using Minimum Wall Thickness and Minimum Yield Strength.

Other sizes/wall thickness available on request.

Tube Body Load: Yield & Tensile Minimum calculated on Specified Wall.

Hydro Test: Test Pressure Value is 90% of the Minimum Internal Yield Pressure Rating.

Internal Yield: Internal Pressure to cause yielding using Minimum Yield Strength and Minimum Wall Thickness.

Maximum Working Pressure is a function of tube condition and is determined by the user.

HS-110™ CM™

(CONTINUOUSLY-MILLED TUBING)

PRESSURE CAPACITY

Documento similar