Ratio de Cobertura de Cartera Irregular
RESEÑA Y PERSPECTIVA OPERATIVA Y FINANCIERA
The M2000 uploads the configured data of the NE to the CME server on schedule, based on the NE selected by the user. Through scheduled synchronizing with the data on the existing network, the CME obtains the latest NE data for configuration.
l The RNC or NodeB exists on the current network.
Context
l The CME upload task is scheduled by the user.
l The CME upload task can be performed once or periodically. The options of Period are
day, week, and month.
l The CME upload task can be performed only on the RNC and the NodeB.
Procedure
Step 1 Choose Maintenance > Task Management. The Task Management window is displayed. Step 2 Click New. The New Task dialog box is displayed.
Step 3 Set the basic information of the task.
1. In the Task Name box, enter the task name.
2. In the Task Type navigation tree, select the CME upload task. 3. In the Run Type field, click Once or Period.
Step 4 Click Next to set the execution time of the task.
Step 5 Click ... and select the start time of the task in the displayed Date/Time Selection dialog box. NOTE
Start Time must be later than the current time of the server.
Step 6 Perform the corresponding operations according to the task running type, once or periodical.
Task Running Type Operation
Once Go to Step 7.
Period Specify Period and Run Times and then go to Step 7.
Step 7 Click Next and select the type of the target NE. The user can select All NE or select a specific NE. Step 8 Click Finish.
The new CME upload task is displayed in the task list. ----End
7.2.5 Creating a Planned Data Area
This describes how to create a planned data area and add an RNS into this area before data configuration on the CME integrated into the M2000. RNS data can be obtained from the current data area after data synchronization.
7 Operating the CME
WRAN CME WRAN CME User Guide
7-50 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
Prerequisite
l The CME client is started.
l 7.2.2 Loading Data from the Existing Network is complete.
Procedure
Step 1 Choose Planned > Create Planned in the main window. The New Plan dialog box is displayed, as shown in Figure 7-37.
Figure 7-37 Create a planned data area
Step 2 In the Plan Name box, enter the name of the planned data area to be created. You can define the area name. Different users can define different plan names. Step 3 Click OK. The planned data area is created.
When the planned data area is created, the area is displayed in the drop-down list under the menu bar of the CME main window, as shown in Figure 7-38.
Figure 7-38 Creating a planned data area successfully
Step 4 Load RNS data into the current data area.
1. In the navigation tree, right-click RAN and then choose Add RNS from the shortcut menu. The Select RNS dialog box is displayed, as shown in Figure 7-39.
Figure 7-39 Loading RNS data
The dialog box displays the RNSs available in the current data area. 2. Select the RNSs to be loaded to the planned data area, and then click OK. ----End
7.2.6 Opening a Planned Data Area
This describes how to open a planned data area before you configure data or resume data configuration.
Prerequisite
l The CME client is started.
l 7.2.5 Creating a Planned Data Area is complete.
Context
One user can open only one planned data area at a time.
Procedure
Step 1 In the main window of the CME, choose Planned > Open Planned. The Select Plan dialog box is displayed, as shown in Figure 7-40.
7 Operating the CME
WRAN CME WRAN CME User Guide
7-52 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
Figure 7-40 Selecting a planned data area
Step 2 In the drop-down list, click the planned data area to be opened. Then click OK. The planned data area is opened.
----End
7.2.7 Synchronizing RNS Data
This describes how to synchronize the RNS data in a planned data area with that in the current data area on the CME that is integrated into the M2000.
Prerequisite
l The CME client is started.
l An RNS is created in the planned data area.
l No RNS to be synchronized is open on the CME client.
Context
Scenarios for RNS data synchronization:
l Before you configure the data in the planned data area, synchronize the data with that in
the current data area.
Procedure
Step 1 In the RNS navigation tree on the left of the CME main window, select the RNS to be synchronized, and then choose Planned > Synchronize RNS on the menu bar. The Select RNS dialog box is displayed, as shown in Figure 7-41.
Figure 7-41 Selecting the NEs to be synchronized
Step 2 Select the NEs to be synchronized, and then click OK. The CME starts synchronizing the planned data area with the current data area. After the synchronization, the RNS data is refreshed. ----End
7.2.8 Opening an RNS
You need to open an appropriate RNS to continue an incomplete data configuration task.
Prerequisite
l The CME client is started.
l No RNS is open on the CME client.
l The RNS to be opened exists in the CME database.
Procedure
In the main window of the CME, right-click the RNS to be opened, and choose Open RNS on the shortcut menu.
----End 7 Operating the CME
WRAN CME WRAN CME User Guide
7-54 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
7.2.9 Checking Data
This describes how to check global data and Iub interface data. You need to check data integrity and redundancy after data configuration or reconfiguration.
7.2.9.1 Scheduled Data Check
The CME integrated into the M2000 can check consistency and redundancy of the RNC data on schedule. This describes how to schedule a data check task and how to view the check report.