• No se han encontrado resultados

The HP OpenView Operations for UNIX Integration (referred to as OpenView) is Operations Center’ 

component for integrating with the HP OpenView Operations product line from Hewlett‐Packard.

OpenView supports configurations where the management server can reside on the same or different  machine as the Oracle database. The OpenView integration supports both configurations.

The integration relies on efficient sampling of the different database tables for retrieving new and  updated message and server data. The OpenView messages contain a number of time stamps that  record the message state‐transitions that can be extracted for recording business metrics.

Configure the OpenView integration to enable or disable management functions (e.g.,  acknowledging alarms) within the Operations Center environment. There are three possible  integration strategies:

Š OpenView Server Install Integration strategy: Install Operations Center and configure the HP  OpenView Operations for UNIX adapter on the host OpenView server. This configuration  enables management functions and does not require installing an ORB on the management  server.

Object Type Property

Incident severity

Node Group status

Node status

Interface status

IP Address none

IP Subnet none

L2 Connection status

Property Value Severity/Condition

CRITICAL CRITICAL

WARNING INFO

MINOR MINOR

MAJOR MAJOR

NORMAL OK

DISABLED UNKNOWN

UNKNOWN UNKNOWN

NOSTATUS UNKNOWN

Š OVOORB Integration strategy: Install the OVOORB on each OpenView server. This strategy 

Š Section 2.13.1, “Integrating Operations Center with HP OpenView Operations for UNIX,” on  page 95

Š Section 2.13.2, “Quick Start for default OpenView Installations,” on page 96

Š Section 2.13.3, “View‐only Integrations,” on page 96

Š Section 2.13.4, “Hierarchy File and Alarm Fields,” on page 96

Š Section 2.13.5, “Historical Alarms,” on page 96

Š Section 2.13.6, “Alarm Counts,” on page 96

Š Section 2.13.7, “Alarm Operations,” on page 98

Š Section 2.13.8, “Management Operations,” on page 99

Š Section 2.13.9, “Executing OVO Applications,” on page 100

2.13.1 Integrating Operations Center with HP OpenView Operations for UNIX

Review this section to determine the best strategy for integrating Operations Center with 

For more instructions, see Chapter 10, “ORB Installation,” on page 251.

4 Create an adapter for each instance of HP OpenView Operations.

For more instructions, see Section 5.1, “Creating an Adapter,” on page 193.

5 Modify the HP OpenView adapter properties.

For more instructions, see Section A.15, “HP OpenView Operations for UNIX,” on page 319.

2.13.2 Quick Start for default OpenView Installations

The integration adapter properties default values match the default OpenView Installation.

To integrate OpenView using the default OpenView installation:

1 Create an adapter for the HP OpenView Operations system.

For more instructions, see Section 5.1, “Creating an Adapter,” on page 193.

2 Set the DB Host adapter property equal to the hostname of the Oracle database server.

3 Set the DB Pass adapter property equal to the password of the Oracle user specified when  configuring the adapter.

The default adapter property value is OpC_op.

4 Start the adapter.

2.13.3 View-only Integrations

To create a view‐only integration:

1 Create an adapter for the HP OpenView Operations system.

For instructions, see Section 5.1, “Creating an Adapter,” on page 193.

2 Verify that the following properties are specified: DB Host, DB Name, DB Poll, DB Port, DB  Type, and DB User.

3 Leave the following properties unspecified (empty): OVO Password and OVO Server.

4 Start the adapter.

2.13.4 Hierarchy File and Alarm Fields

The integration ships with a default hierarchy file, DefaultOVOHierarchy.xml. The file contains a  list of all of the available alarm fields that the Operations Center XML generator can evaluate.

2.13.5 Historical Alarms

Historical alarms are acknowledged alarms that exist on the OpenView server.

To display only real‐time alarms and hide all acknowledged alarms in Operations Center:

1 Create an alarm filter in the Operations Center console to display only alarms that are not  acknowledged (where Acknowledged equals False).

 For more information see  Filtering Alarms the Operations Center 5.0 User Guide.

2.13.6 Alarm Counts

The following status bars in the Operations Center Alarms view display alarm counts:

Š The filter bar displays the total number of active alarms by severity regardless of alarm  ownership:

Š The title bar identifies the total number of active alarms by severity with regard to alarm  ownership:

These counts do not include alarms owned by the current and other users.

Š The status bar identifies the total number of active alarms regardless of alarm ownership.

It is located at the bottom of the window and shows a single tally of all alarms.

For example, assume nine active alarms are the responsibility of an OpenView user. There are no  messages owned by this or any other user. Figure 2‐8 shows the Operations Center Alarms view for  these nine alarms:

Figure 2-8 Alarms View

Both the Filter and Title Bar show 1 MAJOR alarm, 2 INFO alarms and 6 OK alarms. The Status bar  shows the total number of alarms equals 9.

Figure 2‐9 shows the alarm counts from OpenView’s Message Browser. It shows 1 MAJOR alarm, 2  INFO alarms and 6 Normal (OK) alarms, the same as Operations Center. Note the 2 ownership  counts (the pink and white counters) both show 0.

Figure 2-9 OpenVieew Message Browser shows the same alarms as Operations Center

Now, assume the operator right‐clicks the INFO alarm with the message SWAP Utilization (92.00%)  is greater than 80.00% and then clicks Own from the drop‐down menu. The operator claims 

ownership of the alarm. The alarm remains in the browser. The new counts are shown in Figure 2‐10.

In Figure 2‐9, the filter bar shows 1 MAJOR alarm, 2 INFO alarms and 6 OK alarms. The status bar  also shows the total number of alarms, 9 (1 + 2 + 6). Neither indicator changes based on alarm  ownership.

However, note that the title bar count changed. It now shows 1 MAJOR alarm, 1 INFO alarm, and 6  OK alarms. Alarm ownership affects these counts. When the operator claimed ownership of the  alarm, the number of INFO alarms in the title bar count decreased by 1. Note that the alarm is still  visible in the Alarms view.

In Figure 2‐10, OpenView’s message browser alarm counts show 1 MAJOR alarm, 1 INFO alarm, and  6 OK alarms. Note the “owned by me” counter (the pink one) increased by 1.

Figure 2-10 OpenView Message Browser: The pink “owned by me” counter increased after the alarm ownership changed

To summarize:

Š Alarm ownership affects the title bar counts.

Š The filter and status bars in Operations Center display the total number of alarms, regardless of  alarm ownership.

Š Operations Center does not display the “owned by me” and “owned by others” counter  displayed in the OpenView message browser window.

2.13.7 Alarm Operations

The following operations are available for all alarms:

Š Properties: Shows all the details about a single message.

Š Print: Sends output to printer.

Š Additional management right‐click alarm operations are available to the user depending on the  integration strategy selected when integrating HP OpenView Operations for UNIX (see “Adding  Custom Alarm Properties” on page 90).

To enable these additional management operations, one of the following must occur:

Š An existing Operations Center server installation is on the same machine as the OpenView  management server.

Š The OVOORB must be deployed.

To configure Operations Center on the OpenView Management Server, do the following as  necessary: