Note: This detail should be used only where the deck is supported by the wall. An expansion joint detail should be used for non wall-supported deck. Contact BITEC Technical Services if building movement is a concern.

24" max.

4" min.

BITEC base flashing membrane, extend 2" minimum up under wall flashing membrane

BITEC modified bitumen membrane with opt. surfacing or coating, extend 4" min. above cant

1st and 2nd ply as required, fully adhered, extend 2" min. above the cant. Set in hot asphalt.

Exterior plywood on cleat or tapered blocking to provide shape

Cant strip, securely nailed or set in bitumen Wood blocking, secured with appropriate fasteners, match insulation thickness

Fasteners 8" o.c. above base sheet Coping - Designed to meet FMRC 1-49 requirements

Wall flashing membrane

Fasteners approx. 18" o.c. at coping

Fasteners 8" o.c.

Sealant

Termination bar Counterflashing Solid wood blocking

Prime masonry surfaces

Exterior siding, brick, etc.

Modified bitumen or asphalt bleed out at edge of base flashing

,





,,









,, ,, ,,

Note: This detail should be used only where the deck is supported by the wall. An expansion joint detail should be used for non wall-supported deck. Contact BITEC Technical Services if building movement is a concern.

Modified bitumen or asphalt bleed out at edge of base flashing

Base sheet and/or 1st ply as required, fully adhered, extend 2" min. above the cant BITEC base flashing membrane,

extend 2" up under wall flashing membrane

BITEC base flashing interply membrane, extend 2" min. up under the next membrane

BITEC modified bitumen membrane with optional surfacing or coating, extend 4"

minimum above cant

One or two pies of Type IV or Type VI interply felts set in hot asphalt; extend to 4"

above the cant

Fasteners 8" o.c. above the base sheet Fasteners approx. 18" o.c. at coping Coping - Designed to meet FMRC 1-49 requirements

Fasteners 8" o.c.

Termination bar Counterflashing

24"

max.

Wall flashing membrane Interply membrane(s)

Solid wood blocking

Prime masonry surfaces Exterior plywood on cleat or

tapered blocking to provide shape

Exterior siding, brick, etc.

(masonry wall construction shown)

Cant strip, securely nailed or set in bitumen Wood blocking, secured with appropriate fasteners, match insulation thickness

Sealant

4" min.

7B. High Parapet Base Flashing at Masonry Walls

7C. Multi-Ply Base Flashing at Masonry Parapets

BUR-MOD SYSTEMS

Required for 15 & 20 Yr. Warranty For 10 or 12 Yr. Warranty Only BUR

MOD

BUR MOD

,







,, ,,









Note:

Sheet lead minimum of 2-1/2 lbs. per foot.

4"

Roll lead flashing 1"

down into the pipe

Modified bitumen or asphalt seal around all pipe penetrations

Modified bitumen target flashing over the field membrane joints.

Base sheet or 1st, and 2nd ply as required

BITEC modified bitumen field membrane with optional surfacing or coating Set lead flange in modified bitumen sealant. Prime the flange top and bottom before stripping. 4" min. flange width

BITEC smooth surface modified bitumen collar membrane, extend 6" min.

beyond edge of metal flange Roof insulation

Plumbing vent stack

Treated wood blocking

Modified bitumen sealant

Rounded corners

Modified bitumen or asphalt bleed out at edges

,















,





,



, , , , ,

Note

This detail allows the opening to be completed before the stack is placed. The metal sleeve and the clearance necessary will depend on the temperature of the material handled by the stack.

4" min.

Roof insulation

Wood curb, 10" nominal height

Cant strip, set in bitumen or nailed

Metal sleeve where required (Insulate void for cold pipes) Wood blocking, secured to

deck with appropriate fasteners, match the insulation thickness

High temperature Elastomeric sealant if not welded

BITEC modified bitumen base flashing with 8" min. height above roof surface

BITEC modified bitumen field membrane with optional surfacing or coating. Extend 4" min. above cant

Base sheet or 1st, and 2nd ply as required, extend 2" min.

above cant. Set Type IV &

Type VI ply felts in hot asphalt Draw band or weld the umbrella to stack Metal umbrella

(Rain collar or storm collar) Seal top of flashing with fabric tape and sealant

Counterflashing fastened approx. 12" o.c. with a minimum of 3 per side Removable counterflashing Fasteners approx. 8" o.c.

Rounded corners

Modified bitumen or asphalt bleed out at edges

28. Plumbing Vent Flashing

30. Hot Stack Flashing Curb

BUR-MOD SYSTEMS

For 10 or 12 Yr. Warranty Only BUR

MOD

BUR MOD

For 10 or 12 Yr. Warranty Only

GENERAL REQUIREMENTS

N O T E S

All Information is given in good faith, but nor-mal tolerances of manufacture and testing will apply. BITEC reserves the right to improve and change its products at any time without prior notice or advice. The use of BITEC prod-ucts is determined by local conditions and

indi-vidual requirements of each contract. In con-sideration of the many factors involved, BITEC cannot be held responsible for the application of its products and for conditions beyond its control. All claims filed against BITEC war-ranties will be subject to the provisions set

forth at the date of warranty issuance, and any addendums thereto. Under no circum-stances will BITEC be held liable for any age, whether personal injury or property dam-age, which occur during or after the application of the membrane.

TM

Visit our web site at www.bi-tec.com

MANUFACTURERS OF ADVANCED TECHNOLOGY WATERPROOFING MEMBRANES P.O. Box 497 • Morrilton, Arkansas 72110 • Fax (501) 354-3019 • Phone (800) 535-8597

#4-3M-01/02-6