The front panel allows you to adjust the water temperature and view the operating status or error codes. Remove the protective sheet from the front panel before using it.
4.4.1 LCD Display
DISPLAY (Icon) Function Remarks
Heating
Displays Heating icon upon heating demand (Space Heating mode)
Hot Water
Displays Hot Water icon upon hot water demand (DHW setting mode)
Supply water Control
Displays the Supply Water Control mode status
Return Water Control
Displays the Return Water Control mode status
Segment
Displays the data set in each Segment according to display status
Combustion
Displays the Combustion status. Flashes the Combustion icon at 1 second intervals when performing combustion freeze protection
Checkup (Error)
Displays the Error icon when an error occurs. The Boiler may still maintain basic operations (temperature settings, etc.) if it displays the error icon only.
Outdoor Reset
Displays the Outdoor Reset function status
GPM Displays the system flow rate (in GPM)
Psi
Segment Status Display Function Remarks WAIT Shown while waiting for a response from the Main Controller when the Boiler performs an error test or error history load
RST Shown on Error Reset
CLR Shown on deleting the error history and parameters.
INIT Shown on Factory Reset
4.4.2 Buttons
Button
Description or Name Diagnostic Reset Power Mode Plus Minus
Short Key Function Remarks
[Diagnostic] short key Display of information for service
[Mode] short key Sets heating temperature/hot water temperature Displays/confirms of information for customers
Converts () in order of Setting heating temperature
=> Setting hot water temperature => Displaying customer information => Setting heating temperature (in Normal Mode only)
[Reset] short key Error code release/cancellation
[Plus] short key Item movement/increase and displays Level 1 Error code (for Level 1 Error status)
Long Key Combination Function Remarks [Power] long key
(300msec) Power ON / OFF [Mode] long key
(2 seconds) Error history display
Must be in normal mode or Error Display mode
[Reset] long key
(5 seconds) Individual deletion of Error History / Tech Data Works only at the relevant mode
[Diagnostic] long key
(5 seconds) Advancement into Test Menu
Must be in normal mode 1. Parameter Setting 2. Error Check Mode Menu
3. Operation condition setting mode [Diagnostic] long key
(10 Seconds) Version display Possible only with power turned OFF
[Diagnostic]+[Plus] +[Reset]+[Power]
long key (5Seconds) Factory reset Possible only with power turned OFF
※ All button LEDs will be turned on to their maximum when buttons are pressed, and will be turned on at medium brightness at 5 second intervals from the moment they are released and will be completely turned off after maintaining minimal brightness for 5 and 10 second periods.
※ The button will be recognized as pressed once only when released after being pressed for over 50 msec from the time of pressing (Short Key)
※ If the button is pressed until the Long Key reference time from initial pressing, then it will be recognized as a Long Key at the time the conditions are met.
4.4.3 Turning the Boiler On or Off
To turn the boiler on or off, press the [Power] button.
If the unit is experiencing an error the error code will continue to display on the front panel even if the unit is turned OFF.
Item Description Display
Power ON Normal Operating mode with Power turned On
When the temperature of the present supply water is 120℉
and the water pressure is 12.3psi (Fahrenheit specification)
5 sec flashing
When the temperature of the present supply water is 60.0℃
and its water pressure is 12.3psi (Celsius specification) 5 sec flashing Power OFF Off status with power Off
All displays off except status icons (the status icon is shown normally according to function status)
※ When the power is first applied, please turn the panel segments and icons on for 3 seconds (in order to check LCD defect)
※ The firmware version of panel will be displayed for 2 seconds after 3 seconds from power application
NOTE
If the Air purge is operating, the Segment repeats to display ‘AIR’ for 5 seconds and water pressure for 5 seconds. When displaying the water temperature of the space heating supply, the supply or return water icon flashes, depending on the space heating control mode
4.4.4 Normal Operation
1. Enter <Normal Operating mode> pressing the [Power] button for more than 300ms at Power Off mode> 2. The Boiler will display the temperature and pressure of
present supply water at 5 second intervals.
3. The Segment repeats to display ‘AIR’ for 5 seconds and water pressure for 5 seconds while Air Purge is in operation 4. When displaying the temperature of present supply water
(for 5 seconds) , the Supply water Control and Return Water Control icons flash according to the Heating Control mode.
5. The Psi icon flashes when displaying the water pressure (for 5 seconds)
6. The Error icon flashes at 1 second intervals when a Level 1 error occurs.
7. Pressing the [+] or [-] button briefly when a Level 1 error occurs will convert the Boiler to <Level 1 Error Display mode>. <Level 1 Error Display mode> displays the error code and returns to <Normal Operating mode> after 5 seconds. When the error is released during <Level 1 Error Display mode>, the Boiler will convert to <Normal Operating mode>. However, the Boiler will not accept any input from the button during <Level 1 Error Display mode>.
8. For a Level 1 error, pressing Auto Release or [Reset] button once will release the error after displaying ‘RST’ for 3 seconds, if the Boiler meets the conditions to release the error.
9. The Boiler operates normally during a Level 1 error. 10.Entering <Error History mode> is available via <Normal
Item Description Display