[PDF] Top 20 Diseño de un sistema de gestión ambiental basado en la norma ISO 14001 en un Servicio Postventa Oficial VW
Has 10000 "Diseño de un sistema de gestión ambiental basado en la norma ISO 14001 en un Servicio Postventa Oficial VW" found on our website. Below are the top 20 most common "Diseño de un sistema de gestión ambiental basado en la norma ISO 14001 en un Servicio Postventa Oficial VW".
Intraoperative use of spectral-domain optical coherence tomography during Descemet’s stripping automated endothelial keratoplasty
... intraoperatively during DSAEK using a handheld Fourier-domain OCT (Bioptigen Inc, Durham, NC), which has a resolution of 10 µ ...The use of a higher resolution ... See full document
12
The Graft Thickness in Descemet Stripping Automated Endothelial Keratoplasty: What Is the Importance to the Final Visual Outcome?
... used during graft ...segment optical coherence tomography (AS-OCT), during the post- operative ...(calculated during graft preparation) and the thickness measured in the ... See full document
50
<p>Microscope Integrated Intraoperative Optical Coherence Tomography-Guided DMEK in Corneas with Poor Visualization</p>
... Fuchs endothelial corneal dystrophy (n=4), failed graft (n=2), iridocorneal endothelial syndrome (n=1) and failed Descemet stripping automated endothelial keratoplasty ... See full document
7
Descemet stripping automated endothelial keratoplasty in Fuchs’ corneal endothelial dystrophy: anterior segment optical coherence tomography and in vivo confocal microscopy analysis
... stroma, Descemet membrane and endothelium) and of their cellular components (superficial and basal cells, nerve fibers, stromal keratocytes, endothe- lial cells) ...performed during preoperative evaluations ... See full document
14
Confocal microscopy findings in deep anterior lamellar keratoplasty performed after Descemet's stripping automated endothelial keratoplasty
... segment optical coherence tomography (OCT) by Visante (Carl Zeiss, Meditec, Jena, Germany) showed mild diffuse anterior stromal opacity which was inferred to be due to the chronic nature of the ... See full document
39
Correlation of anterior segment optical coherence tomography measurements with graft trephine diameter following descemet stripping automated endothelial keratoplasty
... The use of high resolution ASOCT scans in the future will also provide greater de- tail with more quantitative measurements that may be useful in studying outcomes and optimizing surgical ...maximize ... See full document
11
Visualization of precut DSAEK and pre-stripped DMEK donor corneas by intraoperative optical coherence tomography using the RESCAN 700
... Descemet’s stripping automated endothelial keratoplasty (DSAEK) [1–7] or Descemet’s membrane endothelial keratoplasty (DMEK) has been preferably used for the treatment of corneal ... See full document
150
Evaluation of retinal nerve fiber layer thickness and optic nerve head changes in early to moderate glaucoma patients and compare them with age matched individuals using spectral domain optical coherence tomography
... /6 6/6 16mmhg 19mmhg Open Open -5.23dB -12.35dB 7.47dB 8.14dB 486µ 486µ 76µ 75µ 2.56 1.86 0.78 0.98 0.67 0.71 0.65 0.7 0.455 0.433 105µ 65µ 95µ 79µ 35µ 60µ 62µ 33µ 11 3269526 Muthukamatchi,G 50 M POAG POAG 6/6 6/6 16mmhg ... See full document
2
Opacification of hydrophilic intraocular lenses after Descemet stripping automated endothelial keratoplasty
... the endothelial graft had failed several years previously, and it is therefore possible that prolonged low-grade intraocular inflammation was unidentified behind a cloudy ... See full document
21
Suturing Technique to Promote Graft Attachment in Challenging Cases of Descemet Stripping Endothelial Keratoplasty
... Mean endothelial cell count measured by specular microscope (EM-3000, Tomey, Erlangen, Germany) was 1569 cells/mm² at 12 months postoperatively, representing a mean endothelial cell loss of ... See full document
30
<p>Visibility of the Retina Through an Air-Filled Anterior Chamber During Simultaneous Vitrectomy and Descemet’s Stripping Automated Endothelial Keratoplasty</p>
... Although modern small-gauge PPV has become a very safe procedure, the potential risk remains for intraopera- tive iatrogenic retinal detachment, which may require tam- ponade of the retina. The present study described ... See full document
9
Descemet-stripping automated endothelial keratoplasty for vitrectomized cases with traumatic aniridia and aphakic bullous keratopathy
... for Descemet-stripping automated endothelial keratoplasty (DSAEK) is largely limited to phakic or pseudophakic cases of endothelial dysfunction with normal pupils, because the ... See full document
16
Outcomes of Descemet stripping automated endothelial keratoplasty (DSAEK) for corneal endothelial disorders
... IOP was assessed for all the patients pre operatively and also during the immediate postop, 1 month, 3 month and 6 month follow up. Pre operative intra ocular pressure was normal in all the patients. However, in ... See full document
10
Visual and subjective outcomes of phototherapeutic keratectomy after Descemet’s stripping endothelial keratoplasty
... In this paper, we report on a series of a relatively high number of patients with PTK after DSEK and report the results not only of objective criteria such as best corrected visual acuity (BCVA) but also of subjective ... See full document
15
Double-pass microkeratome technique for ultra-thin graft preparation in Descemet's stripping automated endothelial keratoplasty
... Another disadvantage of the double-pass technique is that the second pass may create a smaller diameter cut. Often the largest diameter punch for a given recipient cornea is used to provide more endothelial cells ... See full document
19
Spectral domain OCT versus time domain OCT in the evaluation of macular features related to wet age-related macular degeneration
... Figure 1 (A) Macular horizontal line scan by time domain (TD) OCT. (B) Macular horizontal line scan by spectral domain (SD) OCT. The comparison between the two OCT tools points out that hard exudates ... See full document
11
Macular findings in Spectral Domain Optical Coherence Tomography and OCT Angiography in a patient with Kearns–Sayre syndrome
... 4. Bande Rodriguez M, Pose Bazarra S, Treus Suarez A, Abraldes Lopez-Veiga M, Fernandez Rodriguez MI, Rodriguez Cid MJ. Kearns–Sayre syndrome: ophthalmic manifestations. An Pediatr (Barc). 2015;82(1):e151–3. 5. ... See full document
19
Spectral-domain optical coherence tomography evaluation of postoperative cystoid macular oedema following phacoemulsification with intraoperative complication
... 2010. Intraoperative complication was defined based on similar studies and included the presence of any of the following conditions, whether in isolation or in combination: posterior cap- sule rent, ... See full document
7
Outcomes of descemet stripping automated endothelial keratoplasty using imported donor corneas
... of endothelial cell density (ECD) and viability secondary to prolonged donor death-to-operation time, and unexpected consequences caused by the transportation over longer distances such as tissue damage or the ... See full document
19
<p>Outcome of Descemet membrane endothelial keratoplasty for graft failure after Descemet stripping automated endothelial keratoplasty</p>
... and endothelial cell density (ECD) measurements which were obtained by Pentacam AXL (Oculus GmbH, Wetzlar, Germany) and endothelial microscopic evaluation (Ocu- lus/Nidek CEM-530, Oculus GmbH, Wetzlar, ... See full document
16
Related subjects