pSeries

host

This chapterprovidesinstructions,requirements,andconsiderations forattaching anIBMRS/6000orIBMeServerpSerieshostto astorageunit.

Installing

the

2107

host

attachment

package

on

IBM

pSeries

AIX

hosts

This sectionprovidestheinstructionsto installthehostattachmentpackagefor the storageunit. RunthehostattachmentpackageoneachAIXhostsystem thatis attached tothestorageunit.

Preparing

for

installation

of

the

host

attachment

package

on

IBM

pSeries

AIX

hosts

This sectiondescribespreparingfor installationof thehostattachmentpackageon IBMpSeriesAIXhosts.

1. Attach thestorageunit toyourhostsystem.See“Generalinformationabout

attachingto open-systemshostwithfibre-channeladapters”onpage16. 2. Turn onthehostsystem andallattachments.

3. Ensure thatyouhaverootaccess.

4. Ensure thatyouhaveadministrator knowledge.

5. Ensure thatyouhaveknowledgeoftheSystemManagementInterfaceTool

(SMIT).

Note: Youarenotrequiredto varyoff thevolume groupbeforeyouinstall the

newversion.

Installing

the

host

attachment

package

on

IBM

pSeries

AIX

hosts

This sectionprovidesinstructionsfor installingthehostattachmentpackageonIBM pSeriesAIXhosts.

You musthave superuserauthorityto completetheinstructions.

Note: Thefollowingprocedureisanexample.Theexampleuses/dev/cd0forthe

addressof theCD.Youraddressmightbedifferent.

1. Fromyourdesktop window,type smitinstall_updateto godirectly to the

installationpanel.

2. ClickInstallSoftware andpressEnter.

3. PressF4to opentheInputDevice/DirectoryforSoftwarewindow.

4. SelecttheCDdrivethatyouareusingfor theinstallation,forexample,

/dev/cd0.

5. PressEnter.TheInstallandUpdatefromtheLatestAvailable Softwarewindow

opens.

6. ClickSoftwaretoInstall andpressF4.

7. SelectSoftwarePackagesandpressF7.

Thesoftwarepackagenameisdevices.fcp.disk.ibm.rte.

8. PressEnter.TheInstallandUpdatefromtheLatestAvailable Softwarepanel

opensagainwiththename oftheselectedsoftwarehighlighted.

10. PressEntertoinstallthesoftware.SMITrespondswiththefollowing question:

Are you sure?

11. PressEntertocontinue.Theinstallationprocessmighttakeseveralminutes.A

messagedisplayswhentheinstallationprocessiscomplete. 12. PressF10whentheinstallationprocessiscomplete.

13. ExitfromSMIT.

14. Removethecompactdisc.

15. Restartthehostsystemor unconfigureandreconfigurethedisks.You must

restartthehostsystem orunconfigureandreconfigurethedisksbeforethe changescantake effect.

Upgrading

the

host

attachment

package

on

IBM

pSeries

AIX

hosts

You canupgradethehost attachmentpackageonanIBMpSerieshosts.

For currentinformationabout upgradingthehostattachment packageonanIBM pSeriesAIXhosts,seetheIBMTotalStorageMultipathSubsystemDeviceDriver User’s Guide.

Attaching

with

fibre-channel

adapters

This sectionprovidesinstructions,requirements, andconsiderationsfor attachingan RS/6000 orpSerieshostsystemto astorageunitwithfibre-channeladapters.

Supported

fibre-channel

adapter

cards

for

IBM

pSeries

hosts

Thefollowingfibre-channeladaptersaresupportedfor RS/6000orpSerieshost systems:

v Featurecode 6228

v Featurecode 6239

v Featurecode 5716

This sectionalso describesthehost systemrequirementsandprovidesthe proceduresto attachastorageunittothefollowinghost systems:

v RS/6000

v pSeries

v eServerp5withfibre-channeladapters

v RS/6000ScalablePOWERParallel(SP)Complex

v pSeriesSPComplex

Note: ForanRS/6000or pSerieshost system,youcanuseeither ofthefollowing

topologies:

v Point-to-point(switched fabric)topology

v Arbitratedloop topology

TheRS/6000andpSerieshostsystemsdonotsupportmorethanone host busadapterontheloop.TheRS/6000andpSerieshostsystems supporta directconnection oftheRS/6000andpSerieshostsystemstoa storageunitbyusingthefibre-channelarbitratedloop topology.

For informationaboutrunningMPIOonapSerieshostsystem,orfor alistof open-systems hosts,operatingsystems,adaptersandswitchesthatIBMsupports,

see theInteroperabilityMatrixat

http://www.ibm.com/servers/storage/disk/ds8000/interop.html.

Fibre-channel

attachment

requirements

for

IBM

pSeries

hosts

This sectionlistthefibre-channelattachmentrequirementsforIBMpSerieshosts. This sectionliststherequirementsforattachingthestorageunittoyourhost system:

v Ensurethatyouhave theinstallationscriptfiles.ThesefilesareontheCDthat

youreceivewiththestorageunit.

v Ensurethatyouhave 1MBminimumof harddiskspaceavailableto installthe

AIXhostattachmentpackage.

v Ensurethatyoucanreference thedocumentation foryourhostsystem andthe

IBMTotalStorage DS8000User’sGuide.TheUser’sGuideisontheTotalStorage CDthatyou receivewiththestorageunit.

v Fordetails aboutthereleaselevelforyouroperatingsystem,seethe

InteroperabilityMatrixat

http://www.ibm.com/servers/storage/disk/ds8000/interop.html.

Eitheryou oranIBMservicesupportrepresentative(SSR)mustperformthe following taskstoinstallandconfigureastorageunit:

1. TheIBMSSRinstallsthestorageunitbyusingtheproceduresintheIBM

TotalStorage DS8000ServiceGuide.

2. Eitheryou oranIBMSSRdefinesthefibre-portconfigurationif youdidperform

theinstallationofthestorageunitorfibre-channeladapters.

3. Eitheryou oranIBMSSRconfiguresthehostsystemfor thestorageunit. Use

theinstructionsinyour hostsystempublications.

4. Eitheryou oranIBMSSRcheckstheLUNlimitationsfortheRS/6000and

pSeries.

Note: TheSDDsupports RS/6000andpSerieshostsystemsina clustering

environment.Tohavefailover protectiononanopensystem,SDDrequires atleasttwopaths,andSDDallowsamaximumof 32paths.

Fibre-channel

attachment

considerations

for

IBM

pSeries

hosts

This sectioncontaininformationabout fibre-channelattachmentconsiderations for IBMpSerieshosts.

For upto dateinformationabouttheservers,operating systems,hostadapters, and fabricconnectionsthatIBMsupports,seetheInteroperabilityMatrixat

http://www.ibm.com/servers/storage/disk/ds8000/interop.html.

Thestorageunitsupports eServerBladeCenterJS20withblade8842 when operating inanIBMpSeries,32-bitenvironment.

Verifying

the

configuration

of

the

storage

unit

for

fibre-channel

adapters

on

the

AIX

host

system

This topicprovidesinformationtoverifytheconfigurationof thestorageunitfor fibre-channeladaptersontheAIXhostsystem.

Toverifytheconfigurationof thestorageunitontheAIXhost system,typethe following command: lsdev -Cc disk | grep 2107

Figure46displaysexampleresultsof thecommandif theconfigurationis successful.

Figure47displaysexampleresultsof thelsdiskcommandtolistallthedisksinthe systemswhich donotcontain2107diskdevices.

Making

SAN

changes

for

IBM

pSeries

hosts

This topicdescribesSANchangesthatyouneedtomakeforanIBMpSerieshosts. Before youchangetheswitchportconnectedtothestorageunitortheswitch domain ID,performthestepsbelowtoremovethefibre-channeladapter: The5716, 6228,and6239host adaptercardsdonotsupportdynamicSAN

configurationchanges.DonotchangethedomainIDoftheswitchportof theswitch connected tothestorageunit;otherwise,youmightlosetheconnectionto the storageunit.

1. Run theumountcommandto unmountthefilesonthefilesystem.

For example,typeumountx,wherex isthefile systemname.Ifyou areonan SPhost, goto step2,otherwisegotostep 4.

2. For SPenvironments,typesuspendvsdtosuspendthevirtualshareddiskswith

thevolumegroups.

3. For SPenvironments,typestopvsdto stopthevirtualshareddisksthatare

associatedwiththevolume groups.

4. Run thevaryoffvgcommandforthe2107volumegroup.

For example, type varyoffvg VGname

5. Type rmdev -dl fcs(x) -R onthecommand line to removethe fibre-channel

adapter.Thevalueofx representsthefibre-channelnumberthatyouwantto remove.

6. Type cfgmgrtoreinstalltheadapterandrediscoverthe2107hdisks.

7. Type varyonvgtovaryonthevolumegroups.

8. Remountthefilesystem.

hdisk3 Available 30-68-01 IBM FC 2107 hdisk4 Available 30-68-01 IBM FC 2107 hdisk5 Available 30-68-01 IBM FC 2107 ...

...

Figure46.Exampleofalistofdevicesdisplayedwhenyouusethelsdev-Ccdisk|grep 2107commandforfibre-channel

hdisk3 Available 30-68-01, Other FCSCSI disk device hdisk4 Available 30-68-01, Other FCSCSI disk device hdisk5 Available 30-68-01, Other FCSCSI disk device ...

...

Figure47.Exampleofalistofotherdevicesdisplayedwhenyouusethelsdiskcommandfor fibre-channel.

Support

for

fibre-channel

boot

Thefollowingsectionsdescribetheprerequisites,thetypesofIBMRS/6000or IBM pSerieshoststhataresupported,andrequiredlevelofadaptermicrocode.

Prerequisites

for

setting

up

the

IBM

pSeries

host

as

a

fibre-channel

boot

device

This sectioncontainprerequisitesforsettinguptheIBMpSerieshostasa fibre-channelbootdevice

Note: RS/6000supports fibre-channelbootwithorwithoutSDD.However, ifyou

areusingSDDwithRS/6000SP,youmustinstallAPARIY37451. Beforeyou cansetuptheRS/6000or IBMpSeriesasabootdevice,you must meet thefollowing prerequisites:

v AnIBMpSeriesor IBMRS/6000 systemwiththecorrectleveloffirmware

Forthemostcurrentlistof IBMRS/6000 orIBMpSerieshoststhatare supported,seetheInteroperability Matrixat

http://www.ibm.com/servers/storage/disk/ds8000/interop.html.

v Featurecode 5716at thecorrectmicrocodelevelandrequiresAIX5.2H,AIX5.3,

orhigher.

v Featurecode 6228at thecorrectmicrocodelevel.

v Featurecode 6239needstobeatthecorrectmicrocodelevelandrequiresAIX

5.1ML04andabove. v AIX5.1

FortheSP,PSSPmustbeat3.2withAPARIY22732(includedinPSSP3.2PTF 14).

v Acopyofthedevices.fcp.disk.ibm.rtefile.

For themostcurrentmicrocodeandfirmwarelevels,seetheInteroperabilityMatrix

at http://www.ibm.com/servers/storage/disk/ds8000/interop.html.

Fibre-channel

boot

considerations

for

IBM

pSeries

hosts

This topiclistsfibre-channelbootconsiderationsfor IBMpSerieshosts. Beforeyou planandusefibre-channel,considerthefollowingitems: v Youmust definetherootvgforeach host.

Whenavolumegroup isvariedonline,a reserveisplacedonalldisksinthe group.For rootvg,this groupisnotreleased.Youcannotsharea rootvgvolume betweenhostseven whenyoushutdown allthehostsexceptone.

v Youcancreateonlyonepathto therootvgvolumeduringtheinstallation.

v Ifyouusethemultiboot,scanningforbootable diskstakesmuchlongerwitha

largenumberofaccessiblestorageelementsintheStorageAreaNetwork. v Mirrortherootvolume group(rootvg)

Bymirroringthestorageunitrootvolumegroup, thebase functionalityand reliabilityof theoperating systemfor thestorageunitisnotaffected.

Supported

IBM

RS/6000

or

IBM

pSeries

hosts

for

fibre-channel

boot

This sectionlistssupportedIBMRS/6000orIBMpSerieshostsforfibre-channel boot.

For uptodateinformationabout thehostsfor fibre-channelbootthatIBMsupports, see theInteroperabilityMatrixat

http://www.ibm.com/servers/storage/disk/ds8000/interop.html.

Supported

levels

of

firmware

for

fibre-channel

boot

on

IBM

pSeries

hosts

This topicprovidesinformationaboutthesupportedlevelsoffirmware for fibre-channelbootonIBMpSerieshosts.

For informationaboutthemost up-to-datelevelsoffirmware,goto techsupport.services.ibm.com/server/mdownload/download.html.

Supported

levels

of

fibre-channel

adapter

microcode

on

IBM

pSeries

hosts

This topicprovidessupportedlevels offibre-channeladaptermicrocodeonIBM pSerieshosts.

For moreinformationabouttherequiredlevelofmicrocodefor youradapter,goto http://techsupport.services.ibm.com/server/mdownload

Note: Youmust getthemicrocodefromanIBMWebsite.

Installation

mechanisms

that

PSSP

supports

for

boot

install

from

fibre-channel

SAN

DASD

on

IBM

pSeries

hosts

This topicprovidesinstallationmechanismsforbootinstallfromfibre-channelSAN DASDonIBMpSerieshosts.

You candirecta PSSPto doa bootinstallonanIBMRS/6000SPnodefromthe following items:

v SAN_DISKIDwhichisderivedfromtheworldwideportnameandLUNID

Thisisthepreferredmechanism. v PVID

v HDISK

Support

for

disk

configurations

for

RS/6000

for

a

fibre-channel

boot

install

This sectionliststhemethodsthatyoucanuseto doa diskconfigurationforthe IBMRS/6000for abootinstallfromfibre-channelStorageAreaNetworks(SAN) DASD.

v Mirroredvolume

v Alternatevolume

v Individualvolume

Support

for

fibre-channel

boot

when

a

disk

subsystem

is

attached

on

IBM

pSeries

hosts

This sectionprovidessupportinformationforfibre-channelboot whena disk subsystemisattachedonIBMpSerieshosts.

For alistof opensystemshosts,operatingsystems,adapters andswitchesthat IBMsupports,seetheInteroperability Matrixat

http://www.ibm.com/servers/storage/disk/ds8000/interop.html.

Attaching

to

multiple

RS/6000

or

pSeries

hosts

without

the

HACMP

host

system

This sectionprovidestheinstructionsto attachoneor twostorageunitsto multiple host systemswithouttheHighAvailabilityClusterMulti-Processing(HACMP™) clusteringsolution.

Considerations

for

attaching

to

multiple

RS/6000

or

pSeries

hosts

without

the

HACMP

host

system

This topicprovidesconsiderationsfor attachingto multipleRS/6000 orpSeries hostswithout theHACMPhostsystem.

InstallHACMPto defineandaccessauniquejournaledfilesystem(JFS)filestored onasinglestorageunitfromanyattached hostsystem.

Whenattachingmultiplehostsystemstoa storageunit,considerthefollowing: v Multiplehost systemscannotaccessthesamevolume grouporthesame

journaledfile systemsimultaneously.

v WithoutHACMP,somesystem failuremanagementfeaturessuchasfailover are

notavailable.Therefore,afailureonthestorageunitoranyoneof theconnected hostsystemswillmostlikelyaffect theavailabilityoftheotherconnecteddevices. v Youmust varyonandmountthevolumegroupsandjournaledfilesystemsevery

timeyoustartthesystem.

v Thestorageunitdoesnotallowownershipof volumegroupstomovefromone

systemto another.

v Whenyouusethisprocedure,youcandefinebetween2 -4multiplehost

systems.

Saving

data

on

the

storage

unit

when

attaching

multiple

RS/6000

or

pSeries

host

systems

to

the

storage

unit

You cansavedataonthestorageunitwhenattachingmultipleRS/6000orpSeries host systemstothestorageunit.

Perform thefollowing stepsto preservethedatathatisstoredonastorageunitthat waspreviouslyinstalledandconnectedto ahostsystem.Thisproceduredoes not erase thedataonthestorageunit,butit removesthevolumegroupsfromthehost system:

1. Type umounttounmountallfilesystemsfromallhostsystemsconnectedto the

storageunit.

2. Type fsckoneach ofthefilesystemsonthestorageunitto verifythefile

system integrity.

3. Type varyoffvgto varyoffallthestorageunitvolumegroupsfromallofthe

host systemsconnectedtothestorageunit.

4. Type exportvgtoremoveallofthestorageunitvolumegroupsfromallthehost

systemsconnectedto thestorageunit.

5. Type rmdev -ld hdiskxto deleteall physicalvolumes(hdisks) oneach host

Restoring

data

on

the

storage

unit

when

attaching

multiple

RS/6000

or

pSeries

host

systems

to

the

storage

unit

You canrestoredataonthestorageunitwhenattachingmultipleRS/6000or pSerieshostsystemsto thestorageunit.

This procedureassumesthatyouhavepreservedthedatabyfollowingthe

instructionsin“Savingdata onthestorageunitwhenattachingmultipleRS/6000or pSerieshostsystemsto thestorageunit” onpage91.

1. Check tobesurethatthestorageunitphysicalvolumes(hdisks) areavailable.

Type lsdev -Cc diskto displaythe hdisksonthe hostsystem.

2. Type importvgxxxxwherexxxxisthename ofthevolume groupto restorethe

storageunitvolume groupsto theapplicablehostsystemsthatareconnectedto thestorageunit,onesystem atatime.

3. Type smitchvgto verifythatNoisselectedfor theActivateVolumeGroup

Automatically andAQuorumandof disksrequiredtokeepthevolume group online?

4. Type varyonvgVGnameto vary-onthestorageunit volumegroupsto the

applicable hostsystemsconnectedtothestorageunit.Perform thestepsone system ata time.

5. Type mountto mountthestorageunitvolumegroupsto theapplicable host

systemsthatareconnectedtothestorageunit.Performthestepsonesystem at atime.

6. If youwantto createnew volumegroups,gotostep3 in“Restoringdataonthe

storageunitwhenattachingmultipleRS/6000 orpSerieshostsystemstothe storageunit.”

Running

the

Linux

operating

system

on

an

IBM

pSeries

host

This sectiondescribeshow toattachapSerieshostsystemrunningtheLinux operating systemwithafibre-channeladapter.

Attachment

considerations

for

running

the

Linux

operating

system

on

an

IBM

pSeries

host

ApSerieshost supportstheSubsystemDeviceDriver(SDD)whenusingtheLinux operating system.Thefollowingsectionsprovideinformationthatyouneedto prepareyoursystemfor SDD.You canalsofindinstructionstoinstall andverify SDD.

Storage unitattachmentissupportedeither bydirectlyattachingastorageunitport to thehostadapter,orbyattachingthroughafibre-channelswitch.Youmustspecify theproperattachment topologyusingthestoragespecialist.SelectLoopto indicate directattachment.

Disabling

automatic

system

updates

ManyLinuxdistributionsgiveanadministratortheabilityto configuretheirsystems for automaticsystemupdates. RedHatprovidesthisintheformof aprogramcalled up2date, whileSUSEprovidesit asYaSTOnlineUpdate.Thesefeatures

periodicallyquery forupdatesthatareavailableforeach host,andcanbe

configuredto automaticallyinstallanynew updatesthatit finds.Thisoften includes updates tothekernel.

Hosts thatareattached totheDS8000seriesandrunningtheIBMMultipath