host
This chapterdescribeshowtoattacha Hewlett-Packard(HP)AlphaServer OpenVMShost toastorageunitwithfibre-channeladapters.
Supported
fibre-channel
adapters
for
the
HP
AlphaServer
OpenVMS
host
system
You canattachastorageunittoanHPAlphaServerthatisrunningtheOpenVMS operating systemwiththefollowingfibre-channeladapters:
v KGPSA-CAadaptercard
v KGPSA-DA(FCA-2354) adaptercard
v KGPSA-EA(FCA-2384)adaptercard
Note: YoudonotneedtheSubsystemDeviceDriverbecauseOpenVMSmanages
multipathing.
For informationaboutadapters thatyou canusetoattachthestorageunittothe HPhostandtheHPAlphaServermodels,seehttp://www-
1.ibm.com/servers/storage/disk/ds8000.
Fibre-channel
OpenVMS
attachment
requirements
Reviewthefollowingrequirements beforeyouattachthestorageunittoyourhost system:
v Ensurethatyoucanreference thedocumentation foryourhostsystem andthe
IBMTotalStorage DS8000User’sGuide.TheUser’sGuideisontheTotalStorage CDthatyou receivewiththestorageunit.
v SeetheInteroperabilityMatrixat
http://www.ibm.com/servers/storage/disk/ds8000/interop.htmlfor detailsaboutthe releaselevelforyouroperating system.
v AnIBMservicesupportrepresentativemustinstallandconfigureanIBMstorage
unit.
Fibre-channel
OpenVMS
attachment
considerations
Table5 liststhemaximumnumberofadaptersyou canhavefor anAlphaServer. Table5.MaximumnumberofadaptersyoucanuseforanAlphaServer
AlphaServername Maximumnumberofadapters
800 2 1200 4 4000,4000a 4 4100 4 8200,8400 8 DS10,DS20,DS20E 2
Table5.MaximumnumberofadaptersyoucanuseforanAlphaServer (continued) AlphaServername Maximumnumberofadapters
GS60,GS60E,GS140 8
GS80,GS160,GS320 8
Supported
OpenVMS
feature
codes
For moreinformationaboutthefeaturecodesforthestorageunitandthedistances thataresupportedbyfibre-channelcablesfor thestorageunit,see IBM
TotalStorage DS8000IntroductionandPlanningGuide.
Supported
microcode
levels
for
the
HP
OpenVMS
host
system
For moreinformationaboutthemicrocodelevelsfor thestorageunit,seeIBM TotalStorage DS8000IntroductionandPlanningGuide.
Supported
switches
for
the
HP
OpenVMS
host
system
IBMsupportscascadedswitches inconfigurations upto amaximumof8 switches withamaximumof 3interswitchhopsfor anypath.Usetwo hopsfor normal operationswiththethirdhopreservedforbackup paths.
For moreinformationonsupportedswitches,seetheInteroperabilityMatrixat http://www.ibm.com/servers/storage/disk/ds8000/interop.html
Attaching
the
HP
AlphaServer
OpenVMS
host
to
a
storage
unit
using
fibre-channel
adapters
ThefollowingsectionsdescribeattachingtheHPAlphaServerOpenVMShost toa storageunitusingfibre-channeladapters:
v Confirmtheinstallationoftheoperatingsystem
v InstallingtheKGPSA-xxadaptercard
v Setupthestorageunit
v Confirmswitchconnectivity
v Confirmstorageconnectivity
v Configurestorage
v Restrictions
v Troubleshootingfibre-attachedvolumes
Supported
operating
system
levels
for
fibre-channel
attachment
to
an
HP
OpenVMS
host
This sectionliststhesupportedoperating systemlevelsfor fibre-channelattachment to anOpenVMShostsystem.
You canattachastorageunittoanOpenVMShostwiththefollowingsystemlevels: v 7.3
v 7.3-1
SeetheHPdocument,GuidelinesforOpenVMSCluster Configurations,for a discussionabout workingwithfibre-channeldevicesandsystemparameterssuch asMSCP_CMD_TMO, MVTIMEOUT,andMPDEV_LCRETRIES.
Confirming
the
installation
of
the
OpenVMS
operating
system
This sectionprovidesstepsto confirmtheinstallationof theOpenVMSoperating system.
Ensure thatthestorageunit supportsattachmenttotheOpenVMSoperating system levelthatyouareinstalling.See“Supportedoperatingsystem levelsfor
fibre-channelattachmenttoanHPOpenVMShost”onpage 52for alistof supportedOpenVMSoperatingsystem levels.
1. Usetheshowsystemcommandto showthecurrentversionof theOpenVMS
operating systemthatyouhave installed.Figure28showsanexampleof what isdisplayedwhenyouusetheshowsystemcommand.
2. Ensure thatyouhaveinstalledthemostcurrentversionof patchesand
HP-recommended remedialkits.Somekitsaredependentonotherkits.You must installsomekitsbeforeyou installanotherkit.Seethedocumentationfrom HPformoreinformation.
3. Usetheproductshow historycommandto checkthepatchesthatare
installedonyoursystem.Figure29showsanexampleof whatyousee when youuse theproductshowhistorycommand.
Installing
the
KGPSA-xx
adapter
card
in
an
OpenVMS
host
system
This sectionprovidesthestepsyoumust followtoinstall theKGPSA-xxadapter card.
1. ShutdowntheHewlett-PackardAlphaServerhostsystem.
$ show system
OpenVMS V7.3-2 on node DS20 5-FEB-2004 15:15:16.88 Uptime 1 01:45:09
Figure28.ExampleofshowsystemcommandtoshowsystemcommandontheOpenVMS operatingsystem
$ product show history
--- --- --- --- PRODUCT KIT TYPE OPERATION DATE ANDTIME
--- --- --- --- DEC AXPVMS VMS731_LAN V6.0 Patch Install 04-AUG-200415:34:30
DEC AXPVMS VMS731_UPDATE V1.0 Patch Install 04-AUG-200415:28:37
DEC AXPVMS VMS731_PCSI V1.0 Patch Install 04-AUG-200415:22:10
CPQ AXPVMS CDSA V1.0-2 Full LP Install 04-AUG-200413:59:00
DEC AXPVMS DWMOTIF V1.2-6 Full LP Install 04-AUG-200413:59:00
DEC AXPVMS OPENVMS V7.3-1 Platform Install 04-AUG-200413:59:00
DEC AXPVMS TCPIP V5.3-18 Full LP Install 04-AUG-200413:59:00
DEC AXPVMS VMS V7.3-1 Oper System Install 04-AUG-200413:59:00
--- --- --- --- 8 items found
$
Figure29.Exampleoftheproductshowhistorycommandtochecktheversionsofpatches alreadyinstalled
2. Usetheproceduresthatareprovided bythemanufacturerof theadaptercard
to installtheKGPSA-xxhost adapter.
3. Restart thehost (nonclusteredconfigurations)or eachclustermember
(clusteredconfigurations).
4. Bringeach hostsystemto ahaltconditionat theconsolelevel.
5. Type set mode diagat theHewlett-PackardAlphaServer consoleto placethe
consoleindiagnosticmode.
Note: Thisstepisonly forcertainAlphaServer models.
6. Type wwidmgr-showadapter toconfirm thatyouinstalledeach adapterproperly.
7. If necessary,updatetheadapterfirmware.
Figure30shows anexampleof whatyousee whenyoutype set modediag
and wwidmgr -show adapter. Figure30 shows theworldwidenode name
(WWNN).Youalso needtheworldwideportname (WWPN)toconfigurethe storageunithost attachment.TodeterminetheWWPNfortheKGPSAadapters, replacethe}2} intheWWNNwitha }1}.
Setting
the
mode
for
the
KGPSA-xx
host
adapter
in
an
OpenVMS
host
system
This taskdescribessettingthemodefor theKGPSA-xxhostadapterfor anHP OpenVMShost system.
You mustinstalltheKGPSA-xxhostadapterbeforeyoucansetthemode.
TheKGPSA-xxfibre-channeladaptercardmustbesetto FABRIC.Usethe
wwidmgr -showadapterconsolecommandto seethesettingfor theCur.Topo
and NextTopovariables.Figure31onpage 55showsexampleoutputfromthe
wwidmgrcommand.
1. Type # shutdown -hnow to shutdown the operating system.
2. Place theAlphaServerintoconsolemode.
3. Type wwidmgr -show adapter to checkthemode.Figure31onpage 55shows
exampleoutputfromthewwidmgrcommand. P00>>>set mode diag
Console is in diagnostic mode P00>>>wwidmgr -show adapter
polling for units on kgpsa0, slot 9, bus 0, hose0... kgpsaa0.0.0.9.0 PGA0 WWN 2000-0000-c922-69bf
polling for units on kgpsa1, slot 10, bus 0, hose0... kgpsab0.0.0.10.0 PGB0 WWN 2000-0000-c921-df4b
item adapter WWN Cur. Topo Next
Topo
[ 0] kgpsab0.0.0.10.0 2000-0000-c921-df4b FABRIC
FABRIC
[ 1] kgpsaa0.0.0.9.0 2000-0000-c922-69bf FABRIC
FABRIC
[9999] All of the above. P00>>>
Figure30.Exampleofthesetmodediagcommandandthewwidmgr-showadapter command
4. Type wwidmgr -set adapter -item 9999 -topo fabric to set the KGPSAhost
adaptermode toFABRIC.
5. Type inittoinitializethesystem.
6. Type wwidmgr -show adapter to check themode.
Setting
up
the
storage
unit
to
attach
to
an
HP
AlphaServer
OpenVMS
host
system
with
fibre-channel
adapters
This sectiondescribessettingupthestorageunit toattachtoanHPAlphaServer OpenVMShost systemwithfibre-channeladapters.
Adding
or
modifying
AlphaServer
fibre-channel
connections
for
the
OpenVMS
host
Tocreate,remove,ormodifytheAlphaServer connections,usetheIBM
TotalStorageDSStorage Manager.Whenyoucreateaconnection,itisnecessary to specifytheworldwideportnameofthehostconnection.See“Locatingthe worldwideportname(WWPN),”onpage225for proceduresonhowto locatethe WWPN.
Defining
OpenVMS
fibre-channel
adapters
to
the
storage
unit
This sectionliststhestepsyoumust performto defineOpenVMSfibre-channel adapters tothestorageunit.
You mustcreateastoragecomplexbeforedefiningeach hostadaptertothe storageunit. UsetheIBMTotalStorageDSStorageManager tocreateastorage complex.Youcanusethefollowingmenu path:clickReal-time manager,click
Managehardware,clickStoragecomplexes.
Todefineeachhost adapterto thestorageunit,performthefollowingstepsusing theIBMTotalStorageDSStorage Manager.
Note: Theseinstructionsassume thatyouarefamiliarwiththeIBMTotalStorage
DSStorageManager.
1. LogontotheIBMTotalStorageDSStorage ManagerandclickReal-time
manager,clickManagehardware,clickHost systems. 2. FromtheSelectactionbox,clickCreate,thenclickGo.
3. FromtheGeneralhostinformation screen,completethefollowingfieldsfor
each fibre-channelhost adapter.Whenfinished,click OK. v Hosttype
v Nickname
v Description
4. FromtheDefinehostports screen,specifythehostports forthishost. Click
Addto addeachhost portto thedefinedhostportstable.
item adapter WWN Cur. Topo Next Topo
[ 0] pga0.0.4.1 2000-0000-C923-1765 FABRIC FABRIC
5. FromtheDefinehostWWPNscreen,specifytheworld-wideportnamesforthe
selectedhosts.Whenfinished,clickNext.
6. FromtheSelectstorageimagesscreen,specifythestorageimagefor
attachment. ClickAddto addthestorageimagetotheselectedstorageimages table.Whenfinished,clickNext.
7. FromtheSpecifystorageimage parametersscreen,specifythefollowing
parametersfor eachstorageimage. v Hostattachmentidentifier
v VolumeGroupfor hostattachment
v Typeof I/Oport(any validstorageimageI/OportoraspecificI/Oport)
8. Click theApplyassignmentbuttontoapplythecurrentattachmentassignment.
Usethisbuttontogothroughthispagerepeatedlyfor eachhostattachment identifierthatyouwanttoassignto thestorageimage.Whenfinished,clickOK. 9. FromtheVerificationscreen,verifythedatathatrepresentsthenewhost
attachments.Whenfinished,clickFinish.
Configuring
fibre-channel
host
adapter
ports
for
OpenVMS
Toconfigurethehostadapterports,usetheIBMTotalStorageDSStorageManager.
OpenVMS
fibre-channel
considerations
When youassignanOpenVMShosttoa specificstorageunitadapterport,ensure thatyou donotassignanyotherhost typetothesamestorageunitadapter.Donot allow anyotherhostthatisnotassignedto thatadaptertoaccessthe
OpenVMS-specificstorageunitadapterport.
Using fabriczoning, youmustcreateazonestrictly forOpenVMShosts.The storageunitfibre-channeladapterportto whichyouassignedastorageunithost must resideexclusivelywithinthisOpenVMSzone.Failuretoensurethisexclusivity mightcauseanOpenVMShosttohang. Ifthisoccurs, youmustrebootthe
OpenVMShost.
OpenVMS
UDID
Support
Each OpenVMSfibre-attachedvolumerequiresa user-definedidentifieror unit device identifier(UDID).Thisisanonnegativeintegerthatisusedinthecreationof theOpenVMSdevice name.Allfibre-attachedvolumeshaveanallocationclassof
$1, followedbytheletters,DGA, followedbytheUDID.AllstorageunitLUNs thatyou assign toanOpenVMSsystemmust haveaUDIDsothattheoperating systemcan detectandname thedevice. LUN0alsomust havea UDID;however,thesystem displays LUN0 as$1GGA<UDID>,notas$1DGA<UDID>.SeetheHPdocument,
Guidelinesfor OpenVMSClusterConfigurationsfor moreinformationabout fibre-attachedstoragedevices.
You canusetheIBMTotalStorageDSStorageManageror theDS8000command line interface(DSCLI)to setavalueina storageunit volumenamefield thatis used byAlphaServersystemsastheUDIDfor thevolume. (Inthis document,we provide DSCLI examples.)You canfindtheDSCLI ontheCDthatyoureceive withthestorageunit.SeetheIBMTotalStorageDS8000Command-Line Interface User’s Guideformoreinformation.
TheDSCLIisageneralpurposeutilitythatsupports variousstorageunitfunctions. TheDSCLIallows16alphanumericcharactersasinputwhenyoucompletethe storageunitvolume namefield.OpenVMSUDIDvalues mustbeanintegerwithin
therangeof 0to 32767.Therefore,youmust ensurethattheinput isvalidfor UDID support.TheutilitydoesnotenforceUDIDrules.It acceptsvalues, suchas
AaBbCcDd,thatarenotvalidforOpenVMS.Itispossibleto assignthesameUDID
valueto multiplestorageunitvolumes.However,each volumethatyouassignto an OpenVMSsystem musthave avaluethatisuniquefor thatsystemorthroughout theOpenVMSclusterto whichthatsystembelongs.ReviewtheHPOpenVMS documentation forUDIDrules,andverifythatyourinputisvalid.
Note: VolumeswithUDIDsgreaterthan 9999cannotbeMSCP-servedinan
OpenVMSclusterto othersystems.
ThefollowingexampleusestheDSCLIto addorchangeaname toanexistingDS volume. IntheexampletheDSCLIisininteractivemodeanda configurationprofile file hasbeendefined.ThefinalcommandusestheAlphaServer consoleto list fibre-attachedvolumes.
1. Usethechfbvolcommandtochangethename ofafixedblockvolume:For
example to setthe UIDDvalueto 21, type: chfbvol -name 210001
Thevalueforthename parameterintheDSCLIcommandistheUDIDfieldfor theHPAlphaServer.
Note: Thefirstvolume,LUN0, willbereportedasa CCLdevice, andnotasa
diskvolume.
2. Tomakeavolumegroup called“VMS_A0”andadda volumetoit,type:
mkvolgrp -type scsimap256 -volume 0001 VMS_A0
This commandreturnsthevolumegroupID.Thefollowingisexampleoutput: CMUC00030I mkvolgrp: Volume group V0 successfully created.
3. TocreateanOpenVMShost withtheDSCLIandassociatea volumegroup
with it, type: mkhostconnect -wwname 10000000ABCDEF98 -hosttype HpVms
-volgrp v0 ES40_A
This commandreturnsthehostconnectionID.Thefollowingisexampleoutput: CMUC00012I mkhostconnect: Host connection 0005 successfully created.
4. Todisplaythedefinedattributesfor ahostconnection,type:showhostconnect
0005
Thefollowingisexampleoutput:
Name ES40_A ID 0005 WWPN 10000000ABCDEF98 HostType HpVms LBS 512 addrDiscovery LUNPolling Profile HP - Open VMS portgrp 0 volgrpID V0 atchtopo - ESSIOport all
5. Todisplaythevolumesinavolumegroup, and,itsattributes,type:showvolgrp
v0
Thefollowingisexampleoutput: | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Name VMS_A0 ID V0
Type SCSI Map 256 Vols 002A 0000F 0001
6. Usethe wwidmgr -showwwid commandat theAlphaServer consoleto list
fibre-attachedvolumesthathavebeendetected byitsfibre-channelhost adapters. Ifavolume hasnoUDIDorhasaninvalidUDID,thevolumeUDID numberisminusone(-1)orzero(0).Whenitisbooted,OpenVMSdoesnot detectavolume with-1or 0asaUDIDnumber.
OpenVMS
LUN
0
-
Command
Control
LUN
ThestorageunitassignsLUNnumbersusingthelowestavailablenumber.Thefirst storageunitvolume thatisassignedto ahostisLUN0, thenext volumeisLUN1, andsoon.Whenastorageunitvolume isunassigned,thesystemreusestheLUN numberthatit hadwhenassigninganothervolumeto thathost.
TobecompatiblewithOpenVMS,thestorageunitvolumethatbecomesLUN0for anOpenVMSsystemisinterpretedastheCommandConsoleLUN(CCL),or pass-through LUN.Thestorageunitdoes notsupportCCLcommandfunctions. This storageunitvolume(LUN0for OpenVMS)doesnotdisplaywhenyouissue
the wwidmgr -show wwidAlphaServer consolecommand. WhenOpenVMS is
runninganda UDIDhasbeen setfor thatstorageunitvolume,thestorageunit volume LUN0displaysasaGGAdevice type,notasaDGAdevice.Although OpenVMS doesnotstrictly requireaUDIDfortheCCL, theSHOWDEVICEcommand displays CCLdevicecreationif yousetaUDID.Youcandisplaythemultiplepaths and diagnosefailedpathsto thestoragecontrollerusingtheSHOWDEVICE/FULL
command.
Guidelines:Thefirst storageunit volumethatyouassignto anOpenVMSsystem can becomeLUN0.However, thevolume thatyou assignmustbeusedbythe system foronly supportcapabilityandmustbeattheminimumsize.Ahostcannot use thevolume foranyotherpurpose.MultipleOpenVMShosts,evenindifferent clusters,thataccessthesamestorageunit,canshare thesamestorageunit volume asLUN0, becausetherewillbenootheractivityto thisvolume.
At theAlphaServer console,when youissue thewwidmgr -showwwid command, LUN0 doesnotdisplay.Onlyfibre-channelstoragedevicesarelistedintheoutput. ThestorageunitLUN0ispresentedasaCCLdevice, andtherefore,isnotshown.
Confirming
fibre-channel
switch
connectivity
for
OpenVMS
This sectionliststhestepsyou mustperformto confirmfibre-channelswitch connectivity fortheOpenVMShostsystem.
1. Openatelnetsessionandloginto theswitchasanadministrator.
2. Confirm thateachhostadapterhasperformeda fabriclogintotheswitch.
Figure32onpage 59shows anexampleofwhatdisplayswhenyoutypethe
switchshowcommand.
3. Confirm thateachstorageunithostadapterhasperformeda fabriclogintothe
switch.Figure32onpage59showsanexampleof whatdisplays whenyou type theswitchshowcommand.
| | | | | | | | | | |
Confirming
fibre-channel
storage
connectivity
for
OpenVMS
Perform thefollowing stepsto confirmthefibre-channelstorageconnectivityfor the OpenVMShost system.
1. Resetthehost (nonclusteredconfigurations)or eachclustermember(clustered
configurations).
2. Bringeach hostsystemto ahaltconditionat theconsolelevel.
3. If requiredby thehost, typeset mode diagat theHewlett-PackardAlphaServer
consoletoplacetheconsoleindiagnosticmode.