• No se han encontrado resultados

User Profile | Read Only, Maint., Read/Write, Admin.

The NMS Wake Up Config. command manages the Wake Up trap (Wake Up functionality).

Operations

Verify the Wake Up functionality status

Set the execution parameters and activate the Wake Up functionality Disable the Wake Up functionality

GUI

NMS Wake Up Config. contextual area

See also

Wake Up functionality (info)

Verify the Wake Up functionality status

User Profile | Read Only, Maint., Read/Write, Admin.

1. Select Main > NMS Wake Up Config.

The NMS Wake Up Config. contextual area displays the sending status of the Wake Up trap and the current setting of the relevant sending parameters.

Set the execution parameters and activate the Wake Up functionality

User Profile | Read/Write, Admin.

WARNING The execution parameters (NMS IP Address, Timeout, etc.) cannot be modified when the Wake Up functionality is already active. To modify them, it is necessary Disable the Wake Up functionality and them modify them.

1. Select Main > NMS Wake Up Config.

2. Set the IP address of the server, which the Wake Up trap must be sent to, in the NMS IP Address box.

3. Set the time interval, for which the Wake Up trap is sent at the end of which it is automatically disabled, in the Timeout (Minutes) box.

Typing or selecting the arrows of the box, set a number between 0 and 1440 minutes.

The setting of the value 0 indicates that the trap is sent until when the user manually disables it or the NMS server automatically disables it when intercepts it.

4. Set the physical location (for example, the name of the site) of the equipment in the NE Location box.

The setting of the parameter is optional.

5. Select the Enable option.

6. Press Apply and confirm.

Disable the Wake Up functionality

User Profile | Read/Write, Admin.

1. Select Main > NMS Wake Up Config.

2. Select the Disable option or reset the value present in the NMS IP Address box (value 0.0.0.0).

3. Press Apply and confirm.

NMS Wake Up Config. contextual area

The contextual area displays the configuration parameters of the Wake Up functionality.

Parameter

Status. Transmission status of Wake Up trap. The sending of the Wake Up trap is:

Active, when the Enable option is selected and a valid value (different from 0.0.0.0) is set as IP address of the server (option NMS IP Address).

Inactive, when the Disable option is selected and the value 0.0.0.0 is set as IP ad-dress of the server (option NMS IP Adad-dress).

NMS IP Address. IP address of the server which the Wake Up trap must be sent to. With server we mean the machine where the supervision system NMS5UX-B or NMS5LX or a different man-agement system, able to manage the reception of the Wake Up trap, is installed.

Timeout (Minutes). Time interval for which the Wake Up trap, when enabled, is sent to the server. The setting of the value 0 indicates that the trap is sent until when the user manually disables it or the NMS server automatically disables it when intercepts it.

NE Location. Optional parameter. The user can insert the physical location (for example the name of the site) of the equipment in this field. This information is communicated to the remote manager together with the characteristics of the equipment. The supervision system NMS5UX-B or NMS5LX does not use this information.

Push-button

Apply. Confirm the changes.

Refresh. Update the context.

Help. Open the help on-line.

See also

NMS Wake Up Config. (command)

Set the execution parameters and activate the Wake Up functionality Disable the Wake Up functionality

Wake Up functionality (info)

Wake Up functionality (info)

The Wake Up functionality allows the user enabling the spontaneous forward, from the equipment to a re-mote server, of a SNMP trap for the notification of the equipment commissioning (Wake Up trap).

Auto Discovery

This functionality has been implemented as help to the Auto Discovery modality available in the supervision systems NMS5UX-B and NMS5LX.

The Auto Discovery mode has the purpose to point out new equipment in the network, not man-aged by the supervision system yet. More information about the Auto Discovery modality is re-ported in the relevant documentation.

This chapter shows only the management of the Wake Up trap by the equipment. The imple-mentation of the Wake Up functionality is the following.

WEB LCT

Via WEB LCT application, it is possible:

• Define the IP address of the server where the supervision system, which the trap must be sent to (NMS IP Address option) is installed.

• Define the time interval for which the trap must be sent, after which the sending of the trap is automatically disabled (Timeout option).

If the value 0 is set for the Timeout option, the Wake Up trap will be sent until when the user manually disables it or the NMS server automatically disables it when intercepts it.

• Activate and deactivate the sending of the trap.

To activate the Wake Up functionality, it is necessary to set a valid value (different from 0.0.0.0) as IP address of the server (NMS IP Address option) and select the Enable op-tion.

To deactivate the functionality, it is necessary to select the Disable option or reset the NMS IP Address option (value 0.0.0.0).

When the Wake Up functionality is activated, the equipment starts sending the Wake Up trap every minute for the time interval defined by the user (Timeout option). For example, if the val-ue 60 has been set as timeout, the trap is sent each 60 minutes. At the end of 60 minutes, the sending of the trap is automatically disabled.

If, in the period when the sending of the trap is enabled, the supervision system intercepts the Wake Up notification records the presence of the new equipment in its database and disables the sending of the Wake Up trap by the equipment (trap switch-off).

See also

NMS Wake Up Config. (command) NMS Wake Up Config. contextual area Verify the Wake Up functionality status

Set the execution parameters and activate the Wake Up functionality Disable the Wake Up functionality