• No se han encontrado resultados

El estudio de la víctima

I.2 El retorno de la víctima

I.2.2 El estudio de la víctima

LED

LED Indication Description Constant Red

Customisable to show terminal is in a call and transmitting and also used, when connected to a charger, to show that charging has failed.

Constant Green Terminal is in a call and Receiving or terminal is charging and battery is fully charged

Flashing Amber Incoming individual call or SDS/Status message.

Two Red Flashes Call setup detected Flashing Amber, four rapid

flashes at a time, repeated Transmit Inhibit enabled or Fallback Mode detected.

Intermittent Flashing Red Terminal is trying to connect to a network or Battery low warning

Constant Amber Terminal is charging Short green Flash Terminal is powering on

MOD-06-366 sepura

17 January 2007 Page 87 of 103

TETRA Terminals

User Guide Issue 1 © Sepura Limited 2007

ALERTS

Alerts are generated by the terminal under the circumstances given in the tables below.

A

UDIBLE

A

LERTS

Alert Meaning Specification

Volume Change Alert The terminal is increasing speaker volume same as Warning Alert Battery Low Alert Generated when low battery level is detected 400Hz 500ms

Repeated

Repeat period = 30s Clear Speech Pip Tone Alert Generated whilst in a call without end to end

encryption

775Hz 100ms Repeated Repeat period = 5s Key Click Alert Generated for every key press

Generated for every key press and hold

1500Hz 100ms

Beep Alert Response to user initiated input 400Hz 200ms

Warning Alert Response to non user initiated events 400Hz 200ms

Invalid Function Alert User error 400Hz 1s

Wait For Tx Alert User has pressed PTT but not yet been granted permission to transmit

783Hz 100ms, Off 400ms Continuous

Tx Granted Alert Alert when user is granted permission to transmit in a half duplex call

659Hz 200ms

Tx Not Granted Alert Alert when user is not granted permission to transmit in a half duplex call

659Hz 1s

Lone Worker Prompt Alert Alert to prompt user to press a button whilst lone-worker function is enabled

1500Hz 150ms off 100 ms, repeat 3 times

No Service Alert Terminal is not in service 775Hz 200ms,

400Hz 200ms Generated twice New Message Alert Terminal has received new message 775Hz 500ms, Off 1s

New Emergency Message Alert Terminal has received new emergency status message

775Hz 300ms, 400Hz 300ms Generated ten times Remote Half Duplex Call Alert Called party is being alerted of a Half duplex call

setup

785Hz + 465Hz 1s, Off 1s Continuous

Remote Duplex Call Alert Called party is being alerted of a Duplex call setup

775Hz 2s, Off 2s Continuous Warbled Half Duplex Call Alert Terminal is alerting an incoming half duplex On/off

hook call

785Hz + 465Hz 1s, Off 1s Continuous

Emergency Call Alert Terminal is alerting an incoming Emergency call 500Hz 600ms, Off 400ms Continuous.

Duplex Call Alert Terminal is alerting an incoming Duplex On/off hook call

775Hz 2s, Off 2s Continuous Warbled

MOD-06-366 sepura

17 January 2007 Page 88 of 103

TETRA Terminals

User Guide Issue 1 © Sepura Limited 2007

Alert Meaning Specification

New Call Alert Alert when call setup is complete 523Hz 300ms, 783Hz 300ms Unobtainable Alert Call setup cannot be completed, or remote

disconnection of duplex call.

400Hz 3s

Call Cleared Alert Generated when a call is cleared. 783Hz 300ms, 523Hz 300ms

Engaged Alert User is engaged in a call 400Hz 370ms, Off 370ms

Continuous Battery Flat Alert Generated prior to the terminal switching-off owing

to a flat battery

400Hz 400ms, Off 300ms Generated four times

In Service Alert Terminal is in service same as Warning Alert

Start Listening Alert Alert in half duplex call when someone else has been given permission to transmit

783Hz 200ms

Stop Listening Alert Alert in half duplex call when permission to transmit granted to someone else has ended and no-one else has permission to transmit

523Hz 1s

Stop Talking Alert Alert for initiator of Live Mike emergency call at end of each Transmit cycle

523Hz 1s

Emergency Direct Call Alert Alert to indicate start of Emergency Direct Setup Call to both initiator and receiver

988Hz + 1046Hz 100ms, 1480Hz + 1568Hz 100Ms Generated twice Emergency Call Non Tx Alert Alert in Emergency Group call generated while

terminal not in transmit

Off 7.1s then 554Hz 100ms, 494Hz 100ms,

Tone Signalling Feedback Alert Generated while a key customised to transmit tone signalling is pressed

800Hz

Volume Control Soft Keys Alert Alert to indicate volume has been set using the volume up/down soft keys

1500Hz 100ms

Whisper Mode Enable Alert Alert to indicate that Whisper Mode has been enabled

988Hz 100ms, 1319Hz 200ms

Whisper Mode Disable Alert Alert to indicate that Whisper Mode has been disabled

1319Hz 100ms, 988Hz 200ms

Transmit Inhibit Enable Alert Alert to indicate that transmit inhibit has been enabled

988Hz 100ms, 1319Hz 200ms

Transmit Inhibit Disable Alert Alert to indicate that transmit inhibit has been disabled

1319Hz 100ms, 988Hz 200ms

Transmission Inhibited Alert Alert to indicate that attempted transmission is not allowed

933Hz 1s

Wait for Transmission Alert Alert when user has pressed PTT but has not been granted permission to transmit

783Hz 100ms, Off 400ms Continuous

Transmission Granted Alert Alert when user is granted permission to transmit in a half duplex call

659Hz 200ms

Transmission Not Granted Alert Alert when user is not granted permission to transmit in a half duplex call

659Hz 1s

No Service Alert Alert to indicate that the terminal is not in service 775Hz 200ms, 400Hz 200ms, Generated twice Covert Mode Enable Alert Alert to indicate that Covert Mode has been

enabled

988Hz 100ms, 1319Hz 200ms

MOD-06-366 sepura

17 January 2007 Page 89 of 103

TETRA Terminals

User Guide Issue 1 © Sepura Limited 2007

Alert Meaning Specification

Covert Mode Disable Alert Alert to indicate that Covert Mode has been disabled

1319Hz 100ms, 988Hz 200ms

Gateway Found Alert to indicate the terminal is in range of a Gateway

400Hz 200ms, Off 200ms, Generated three times Gateway Lost Alert to indicate the terminal is not in range of a

Gateway

400Hz 200ms, Off 200ms, Generated twice

Communication Type Mismatch to Direct Alert

Alert to indicate that the terminal is in range of a gateway and is receiving a direct call from another terminal which is outside the range of the Gateway

400Hz 30ms, Off 30ms Generated twice Repeated Repeat period = 5s Communication Type Mismatch

to Gateway Alert

Alert to indicate that the terminal is out of range of a Gateway and is receiving a call from another terminal via a Gateway

400Hz 30ms, Off 30ms Generated three times Repeated

Repeat period = 5s New GPS Destination Alert Generated when the terminal accepts a change of

GPS destination command

1046Hz + 1319Hz 100 ms, 1046Hz + 1568Hz 100 ms Generated twice

Paging Alert Generated to page the user 1319Hz + 1397Hz 500ms,

1397Hz + 1480Hz 200ms Generated continuously.

V

IBRATOR

A

LERTS

Alert Meaning Specification

Voice Call Vibrator Alert Alert to indicate that the terminal has received a hooking call.

500ms on, 500ms off, 500ms on, 500ms off, 500ms on, 2s off.

Message Received Vibrator Alert

Alert to indicate that the terminal has received a Status message or SDS message.

500 ms on, 250 ms off, 500 ms on, 1s off Generated a maximum of 5 times

MOD-06-366 sepura

17 January 2007 Page 90 of 103

TETRA Terminals

User Guide Issue 1 © Sepura Limited 2007