HEALTHCARE1 SPACELABS

HEALTHCARE1 TAEMA TAEMA

BleaseGenius/Genius MRI BleaseSirius Alys 2000 Clarys 2000

WHERE MARKETED Worldwide Worldwide Worldwide, except North

America Worldwide, except North

America

FDA CLEARANCE Yes Yes No No

CE MARK (MDD) Yes Yes Yes Yes

CONFIGURATION Mobile Mobile Mobile Mobile, wall, pendant

PIPELINE GAS INLETS 3 (O2, N2O, air) 3 (O2, N2O, air) 3 (O2, N2O, air) 3 (O2, N2O, air) GAS CYLINDER YOKES 2 maximum 4 maximum 2 optional (O2, air) 2 optional (O2, air) VAPORIZERS, AGENTS Isoflurane, halothane,

enflurane, sevoflurane Isoflurane, halothane,

enflurane, sevoflurane Isoflurane, halothane, enflurane, desflurane, sevoflurane

Isoflurane, halothane, enflurane, desflurane, sevoflurane

Type Plenum-type variable

bypass, fully compensated Plenum-type variable

bypass, fully compensated Variable bypass, heated

(desflurane) Variable bypass, heated (desflurane)

Number 1 maximum 2 maximum 2 1 active, 2 storage

Interlock Fully compatible Fully compatible Yes Yes

SUCTION SYSTEM Optional, direct/venturi Direct Optional Optional

O2 FAIL-SAFE Alarm Multigas cutoff, full alarms Acoustic alarm, N2O block Acoustic alarm, N2O block HYPOXIC MIXTURE

FAIL-SAFE Gear-driven ratio system2 Gear-driven ratio system2 Mechanical limit, O2 alarm Mechanical limit, O2 alarm AUTOMATIC

VENTILATOR 2200 Blease700/900 Electronic controls,

pneumatically driven Electronic controls, pneumatically driven

Bellows, size Adult/pediatric Adult/pediatric 1 size 1 size

Type Ascending, bag in bottle Ascending, bag in bottle Descending Descending Primary controls

Ventilation modes Adult, pediatric, CMV Adult, pediatric, CMV,

PPCV, SIMV+PSV, AdPSV Manual, spontaneous, VC,

PCV Manual, spontaneous, VC,

PCV

Inspiratory flow, L/min 0-100 0-100, variable 0-80 0-80

IE ratio Not specified 2:1 to 1:5 1:3 to 1:1 1:3 to 1:1

Inspiratory pause NA Off, 5-50% 0-20% Ti 0-20% Ti

Pressure limit, cm H2O 20-80, adjustable 10-70, 10-50 pediatrics,

adjustable 10-90, adjustable 10-90, adjustable

PEEP, cm H2O 0-20 variable 0-20 electronic variable

PEEP 0-25 electronic 0-25 electronic

Other controls Adult and pediatric modes,

standby, MV/TV selection Adult and pediatric modes, standby in both modes, spirometry MV/TV selection3

Plateau sigh, expiratory

pause Plateau sigh, expiratory

pause System checks Self-verification test Self-verification and leak

test, dynamic compliance, compensation, fresh-gas flow compensation

Autotest, leakage,

compliance Autotest, leakage,

compliance

MODEL SPACELABS

HEALTHCARE1 SPACELABS

HEALTHCARE1 TAEMA TAEMA

BleaseGenius/Genius MRI BleaseSirius Alys 2000 Clarys 2000

SCAVENGING SYSTEM Active AGSS Active vacuum or exhaust AGSS, high or low flow, passive

Vacuum/exhaust Vacuum/exhaust

AUTO RECORD KEEPER Optional Optional Not specified Not specified

ANESTHESIA DATA

MANAGEMENT Optional Optional External optional, digital

output, RS232 External optional, digital output, RS232 MONITORS

Airway pressure Peak and mean Peak and mean Piezoelectric Piezoelectric

Where measured Y-piece Y-piece Inspiratory limb Inspiratory limb

High-pressure alarm 10-70 cm H2O 70 to -4 cm H2O 11-81 mbar 11-81 mbar Subatmospheric

pressure alarm Not specified -10 cm H2O, fixed, internal Yes Yes

Continuing pressure

alarm PEEP referenced PEEP referenced Yes Yes

Low pressure/apnea 5-60 cm 70 to -4 cm H2O Yes Yes

Other pressure alarms Not specified Low-pressure 5-50 cm H2O,

adjustable, apnea4 None specified None specified

Expiratory volume/flow Not specified MV and TV Yes Yes

Type of sensor Not specified Spirolite expiratory volume Hot wire Hot wire

Where measured Not specified Circuit Expiratory port Expiratory port

Rate alarm Not specified Yes Yes Yes

Apnea alarm Not specified Low expired volume Yes Yes

Reverse-flow alarm Not specified No Yes Yes

High/low minute

volume Not specified Yes Yes Yes

High/low flow Not specified Yes No No

Other expiratory alarms Not specified High expired volume Sensor disconnect, sensor

fail Sensor disconnect, sensor

fail

O2 concentration Adjustable Adjustable alarms Yes Yes

Type of sensor Galvanic cell Galvanic cell Galvanic cell Galvanic cell

Response time, sec Not specified Not specified 5 5

CO2 concentration Not specified Optional External optional External optional Apnea alarm Not specified Adjustable External optional External optional

N2O Not specified Optional External optional External optional

Agent monitors Not specified Optional External optional External optional Type of agents Not specified Not specified External optional External optional

Auto ID Not specified Optional External optional External optional

Agent concentration

alarm Not specified Optional External optional External optional

This is the second of four pages covering the above

MODEL SPACELABS

HEALTHCARE1 SPACELABS

HEALTHCARE1 TAEMA TAEMA

BleaseGenius/Genius MRI BleaseSirius Alys 2000 Clarys 2000

ECG Not specified Optional External optional External optional

Heart rate Not specified Optional External optional External optional

ST segment Not specified Optional External optional External optional

Noninvasive BP Not specified Optional External optional External optional

Invasive BP Not specified Optional External optional External optional

Temperature Not specified Optional External optional External optional

Pulse oximeter Not specified Optional External optional External optional

Other monitors None specified None specified None None

Other features None specified User-definable defaults, language option, waveform, bar graph

None specified None specified

DISPLAYS Not specified Optional Yes Yes

Number Not specified Not specified 2 2

Type Not specified Not specified ED ED

Integrated Not specified No Yes Not specified

Interface with others Not specified Yes Yes (through RS232) Yes (through RS232)

DATA INPUT Not specified No Rotary knob, softkeys,

hardkeys Rotary knob, softkeys,

hardkeys

PRIORITIZED ALARMS Not specified Optional Yes Yes

MRI COMPATIBILITY Yes No Not specified Not specified

PHYSICAL FEATURES

H x W x D, cm (in) 67.5 x 40 x 180 (26.6 x 15.7

x 70.9) 148 x 70 x 75 (58.3 x 27.6 x

29.5) 134 x 69 x 81 (52.8 x 27.2 x

31.9) 134 x 74 x 75 or 75 x 60 x

73 (52.8 x 29.1 x 29.5 or 29.5 x 23.6 x 28.7) Weight, kg (lb) 25 (55.1)3 115 (253.5); without patient

monitors 100 (220.5) 70 (154.4) or 52 (114.7)

Shelves, cm (in) 1, not specified Not specified Not specified Not specified Drawers, cm (in) Optional 1, not specified 3 maximum, multiple

configurations Not specified Not specified

Writing shelf, cm (in) Not specified Optional, flip-up Not specified Not specified

POWER REQUIRED, VAC Battery powered 100-260 100/240 100/240

Auxiliary outlets 1 4 4 4

This is the third of four pages covering the above model(s). These specifications continue onto the next page.

MODEL SPACELABS

HEALTHCARE1 SPACELABS

HEALTHCARE1 TAEMA TAEMA

BleaseGenius/Genius MRI BleaseSirius Alys 2000 Clarys 2000

BACKUP BATTERY Yes Yes Optional Optional

Type AA Internal Not specified Not specified

Use per charge, hr Not specified 2 Not specified Not specified

PURCHASE INFORMATION

Price Not specified Not specified Not specified Not specified

Warranty 1 year 1 year 1 year 1 year

Service contract Optional Optional Yes Yes

Delivery time, ARO Not specified Varies Not specified Not specified

OTHER SPECIFICATIONS MRI compatibility up to

1,000-gauss line. Auxiliary O2 option; front-loading drawer options;

worksurface and flowblock illumination; motion-activated vaporizer lighting;

choice of canister sizes;

touchscreen ventilator control or touch and trak;

auxiliary common gas outlet option.

Automatic compliance compensation; automatic sensor calibration.

Automatic compliance compensation; automatic sensor calibration.

UMDNS CODE(S) 10134 10134 10134 10134

LAST UPDATED May 2008 May 2008 December 2005 December 2005

Supplier Footnotes 1Formerly Blease. 1Formerly Blease.

Model Footnotes

Data Footnotes 2Rotameter controls are knock resistant with a guard in front of them. 3Includes cylinder box and pipelines;

excludes trolley and wall mounting.

21 vaporizer connected to the ventilator and up to 3 vaporizers in parking.

3Fresh-gas compensated.

4Also pressure cycling and low supply-gas pressure.

MODEL TAEMA TAEMA ULCO