Type "A" fire - Dry fire / organic j'yfaygif; (wood, paper, textiles, etc.) Type "B" fire - Fire in combustable liquid (oil fire)
Type "C" fire - Fire in electrical equipment Type "D" fire - Fire in light metals (owåKypönf;) Type "E" fire - Petroleum gas
Type "F" fire - Spontaneously combustable substances. (Coal, Cotton, fish meal)
( D. J. House Seamanships Techniques Pg. 167 )
-F.F.E Class VII
-Fire Fighting Equipments rsm;ESifh Extinguishers rSm - 1. Fireman's out fit & breathing apparatus. 2. International shore connection.
3. Fire pumps, fire mains, hydrants and hoses nozzle. 4. Fire control plans.
5. portable fire extinguishers. 6. Fixed fire extinguisher. 7. Fire alarms systems. 8. Fire Blanket
- Accommodation fire. - E / R fire.
- Cargo hold fire (in port & at sea) - Gallery fire.
F.F.E. CLASS VII (CARGO SHIP)
(1) Vessel navigate vkyfaecsdefwGif crew or passenger a&mufEdkifaom ae&mtm;vHk;udk 2 jets of water
a&mufEdkif&rnf/ ¤if;tjyif any store room ESifh cargo space rsm; empty jzpfonfhtcsdefwGif 2 jets of water a&mufEdkif&rnf/
GT 1000 ESifhtxuf vessel wGif power fire pump tenf;qHk; ESpfvHk;&Sd&rnf/ Fire pump wpfvHk;pDwHk;
onf hydrant ESpfckrS water jet ESpfckudk wpfjydKifwnf; pressure twlwl xGufaeap&rnf/
GT 500 ESifh 1000 Mum;wGif fire pump ESpfvHk;&Sd&rnf/ Pump wpfvHk;onf hydrant wpfckudk pressure
aumif;pGm xkwfay;Edkif&rnf/ Pump wpfvHk;pDjzifharmif;aom Pressure ESpfckwl&rnf/
(2) Emergency fire pump udk GT 500 ESifhtxuf oabFmwdkif;wGif wyfqifxm;&rnf/ ¤if; pump onf puf
cef;\tjyifbufwGif&Sd&rnf/ GT 500 ESifh 1000 Mum; vessel rsm;\ emergency fire pump onf manual operate jzpfEdkifjyD; GT 1000 txufwGif power pump jzpf&rnf/
Fire main &Sd&rnf? water service pipe rsm;ESifh hydrant rsm;&Sd&rnf/
GT 1000 ESifhtxufwGif 30 M (100 ft.) wdkif;wGif fire hose tenf;qHk;wpfck&Sd&rnf/ oabFmwpfpD;vHk;
twGuf tenf;qHk; fire hose ig;ck&Sd&rnf/ &SdorQ fire hose rsm;\t&Snfonf oabFmt&Snf\ 60% &Sd
&rnf/ Hose tydkwpfacsmif;yg&rnf/
GT 500 ESifh 1000 Mum;wGif fire hose tenf;qHk;ESpfacsmif;&Sd&rnf/ ¤if; hose ESpfacsmif;\t&Snfonf
oabFmt&Snf\ 60% &Sd&rnf/ Hose wpfacsmif;tydkyg&rnf/
Oil fire boiler or internal combustion propelling machinery space rsm;wGif tenf;qHk; hydrant
ESpfck&Sd&rnf/ wpfbufwGif wpfckxm;&rnf/ Spray Nozzle wyfxm;&rnf/
(3) &SdorQ accommodation space wdkif;ESifh service spaces rsm;wGif portable fire extinguisher tenf;qHk;
wpfckpDxm;&rnf/ GT 1000 ESifhtxufqdkvQif tenf;qHk; ig;vHk;yg&rnf/ GT 500 ESifh 1000 Mum;wGif
tenf;qHk; 3 vHk;yg&rnf/ Spare charge rsm;yg&rnf/
(4) GT 2000 ESifhtxuf oabFmrsm;wGif cargo space rsm;udk umuG,f&eftwGuf fixed fire smothering gas installation &Sd&rnf/ Gas tpm; steam udk explosive rygaomtcef;rsm;twGuf tpm;xdk;Edkifonf/ Tanker rsm;wGif foam udktpm;xdk;Edkifonf/ Tanker rsm;rSvGJí -
(i) Steel hatch cover &SdjyD;? &SdorQtayguftm;vHk;udk ydwfEdkifonfh vessel rsm;? (ii) Ore, Coal, Grain only omo,faqmifaomoabFmrsm;?
(iii) Short vuoyage oGm;aomoabFmrsm;wGif gas installation rwyfvQifvnf;&onf/ uif;vGwfcGifh
ay;xm;onf/
(5) Oil - fired boilers or oil - burning equipment &Sdaom machinery spaces rsm;wGif fixed fire extinguishing installation &Sd&rnf/ ¤if;onf -
(i) Boiler Room xJwGif 30 gallons (136 litres) qefYonfh foam extinguisher wpfvHk; (odkY) 45 Kg (100 lbs.) qefYaom CO2 extinguisher wpfvHk;&Sd&rnf/
(ii) Portable foam applicator wpfckESifh firing space wpfckpDwdkif;twGuf portable fire extinguisher
ESpfvHk;&Sd&rnf/ oJESifh a*:jym; (SCOOP) &Sd&rnf/
(6) Internal combustion type machinery &Sdaom machinery spaces rsm;wGif pressure water spraying system or smothering gas installation or HHC system wpfck&Sd&rnfhtjyif 45 litres foam extinguisher
wpfvHk; odkYr[kwf 16 Kg. capacity &Sdaom CO2 wpfvHk;&Sd&rnf/
Space wpfckvHk;udk cover jzpfrnfh vHkavmufaom portable extinguisher rsm;&Sd&rnf/
(7) Steam engine ygaom machinery space rsm;wGif ¤if; steam engine udk main engine odkYr[kwf auxiliary engine tjzpfoHk;rnfqdkvQif engine power onf 375 Kw &SdcJhvQif ¤if; engine twGuf fixed installation
wpfck odkYr[kwf 45 litres foam wpfvHk; odkYr[kwf 16 Kg CO2 wpfvHk;&Sd&rnf/ Space wpfckvHk;udk cover jzpfrnfh vHkavmufaom portable extinguisher rsm;&Sd&rnf/
(8) Fire detection and alarm system rsm;udk engine room xJwGif remote control jzifhaomfvnf;aumif;? auto jzifhaomfvnf;aumif;? aqmif&GufEdkif&ef wyfqifxm;&rnf/
(9) Fireman's outfit rsm;udk atmufygtwdkif; o,faqmif&rnf/ GT 500 ESifh 2500 Mum;wGif 2 pHk?
GT 2500 ESifh 4000 Mum;wGif 3 pHk? GT 4000 ESifhtxuf 4 pHk?
Fireman's outfit wpfcktwGuf air-hose type breathing apparatus wpfckyg0ifjyD; usefaom fireman's outfit rsm;twGuf self-contained type jzpf&rnf/ wpfpHkESifhwpfpHk wwfEdkifoí cGJxm;&rnf/
(10) International shore connection wpfcko,faqmif&rnf/ ¤if;udk oabFm\rnfonfh side wGifrqdk wyfqifEdkif
atmif pDpOfxm;&rnf/
(11) GT 500 atmufoabFmrsm;twGuf reduce scale jzifho,faqmifEdkifonf/
Fire Pumps
Emergency fire pump rSvGJí oabFmwGif&Sdaom fire pump rsm;onf total require capacity \ 80%
udkay;Ekdif&rnf/ Emergency pump tygt0if pump wpfckpDwdkif;\ capacity onf not less than 25 M3 / h
&Sd&rnf/ Cargo ship wpfpD;\ total require capacity of fire pump onf 180 M3 / h xufrsm;&efrvdkyg/ - Cargo ship 1000 tons gross ESifhtxufwGif independent fire pump atleast (2)vHk;&Sd&rnf/ - Diesel power fire pump onf 0º C temp: wGif manually vufjzifhvSnfhí vG,fulpGmEdk;Edkif&rnf/ - Pump \ service tank xJwGif fuel tenf;qHk; 3 h armif;Edkifatmif &Sdae&rnf/ Pump onf 15 h contineous armif;Edkif&rnf/ Suction head of pump wdkif;onf in service wGif under all condition of list, trim, roll and pitch wGif a&pkyfEdkifatmif vkyfxm;&rnf/
- Emergency fire pump onf E/R xJwGifr&Sd&/ ¤if;twGuf source of power onfvnf; E/R
xJwGifr&Sd&/
Fire Main
- Fire main ESifh service pipe rsm;\ diameter onf fire pump ESpfvHk; operate vkyfEdkif&ef sufficient
jzpf&rnf/ odkYaomf cargo ships rsm;wGif 140 M3 / h jzifh discharge vkyfEdkif&efom sufficient jzpfzdkY
vdkonf/
- Hydrant wpfckwGif&Sdaom maximum pressure onf fire hose wpfckcHEdkifrnfh pressure xufrydkap&/
Fire Hose
- Administration u approved vkyfaom non-perishable material ESifhjyKvkyfjyD;? ¤if;wdkYtoHk;jyKaom space twGuf sufficient length &Sd&rnf/
Nozzles
- Accommodation twGuf 12 MM xufrMuD;ap&/ - Machinery space rsm;twGuf 19 MM xufydkrMuD;ap&/ - tjcm;ae&mrsm;twGuf 16 MM size rsm;vnf;oHk;Ekdifonf/
Fireman's Outfit Personal Equipment
(1) Steam ESifh fire rS radiation heat udk umuG,fay;Edkifrnfh protective clothing wpfpHk? ¤if;\ outer surface onf water-resistance jzpf&rnf/
(2) Rubber odkYr[kwf vQyfppfrul;Edkifaom material jzifhjyKvkyfxm;onfh boots and gloves
(3) Impact 'PfudkumuG,fEdkifrnfh rigid helmet wpfvHk;?
(4) Electric safety lamp wpfvHk;? ¤if;onf tenf;qHk; 3 em&Dvif;&rnf/ (5) Axe wpfacsmif;? ¤if;onf administration u satisfaction jzpf&rnf/
Breathing Apparatus
(1) Smoke helmet or smoke mask wpfck? ¤if;onf air pump ESifh sufficient length &Sdaom air hose
yg&rnf/ Air hose t&Snfonf 36 M xufausmfvGefvQif self-contained breathing apparatus jzifh
toHk;jyK&rnf/
(2) (Self-contained breathing apparatus ¤if;wGif 1200 litres qefYaom odkYr[kwf 30 min toHk;jyKEdkifaom air cylinders rsm;yg0if&rnf/ ) Spare charges rsm; oabFmay:wGif&Sd&rnf/ Passenger 36 a,mufxuf
ydko,faom passenger ship rsm;wGif spare charge tenf;qHk; 2 ckyg0if&rnf/ ¤if;tjyif air cylinder
rsm;udk interchangable vkyfEdkif&rnf/ Sufficient length &Sdaom fire proof life line ESifh snap hook
yg0if&rnf/
B.A wGif bellow type ESifh self contained [líESpfrsdK;&Sdonf/ Bellow type wGif-
- Smoke mask or smoke helmet wpfck?
- E/R ESifh carog hole \ ae&mwdkif;udk open deck rS hatch way or door way rsm;ESifh well clear
jzpfEdkifonfh vHkavmufaomt&Snf&Sdonfh corrogated fire proof air hose, not more than 36 M
wpfacsmif;?
- Sufficient air ay;Edkifonfh bellow or air pump wpfvHk;yg&Sdonf/ Self contained type wGif -
- Compressed air 1200 liters yg0ifaom air cylinder wpfvHk; odkYr[kwf ESpfvHk;? - yg0ifaomavonf tenf;qHk; 30 min. tvkyfvkyfEdkifatmif vHkavmufrI&Sd&rnf/
- pressure guage onf cylinder xJrS air pressure enf;oGm;vQif alarm jrnf&rnf/
Type ESpfrsdK;pvHk;wGif HARNESS (odkif;MudK;) odkYr[kwf separate belt ESifh attached vkyfEdkifaom snap hook ygonfh vHkavmufaom t&Snf&Sdaom fire proof life line wpfacsmif;&Sd&rnf/ ¤if; life line udkqGJvQif B.A.
jyKwfrxGufap&/ (Life line csdwf&ef belt udk B.A. \twGif;ydkif;wGif 0wfqif&rnf/ ) Life line jzifh operate vkyfaom signal rsm;rSm
bellow type wGif wpfcsufqGJvQif avQmh(slack)
ESpfcsufqGJvQif avydkay; (more air)
oHk;csufqGJvQif csufcsif;xGufcJh^ qGJwif
Self contained type wGif - wpfcsufqGJvQif avQmhay;
ESpfcsufqGJvQif csufcsif;xGufcJh^ qGJwif
B.A udk udk udk udk udk check vkyf&ef vkyf&ef vkyf&ef vkyf&ef vkyf&ef (Monthly)
(1) Emergency by-pass control udk aocsmydwfyg/
(2) Cylinder valve rsm;udkzGifhyg? set xJwGif pressure rsm;vmaomaMumifh alarm jrnfrnf? xdktcsdefwGif pressure gauge udkMunfhjyD; cylinder rsm; fully charge jzpfrjzpf ppfaq;yg/
(3) Apparatus xJwGif air leakage &SdvQif toHMum;&rnf/ vdktyfvQif leakage ae&mrsm;udk aocsmpGm
ppfaq;jyD; tight vkyfyg? over tight rjzpfap&ef owdjyKyg/
(4) Cylinder valve rsm;udk jyefydwfjyD;? pressure gauage udk jyefppfyg/ Gauge rSrDwmonf 30 sec. twGif; zero odkY jyefrusap&/
(5) Mask rS demand valve diaphragm udk zdí air hose xJrSavrsm;ukefatmifvkyfyg/
(6) Pressure gauge shut off valve udkydwfjyD; cylinder valve rsm;udk jyefzGifhyg/ Pressure gauge onf zero
(7) Pressure shut off valve udk jyefzGifhyg/ xdkYaemuf emergency by-pass control udk jznf;jznf;csif;jyefzGifhyg/
xdktcgavrsm;onf demand valve rSwpfqifh xGufvmonfhtoHudkMum;&rnf/ xdktcg control udkjyefydwfyg/ (8) Cylinder valve rsm;udk jyefydwfyg/ Demand valve udkzdí avrsm;xkwfyg/ Pressure gauge rSrDwmonf
avQmhusvmonf 43 ATS (44.5 kg/m3 ) odkYa&mufvQif alarm jrnf&rnf/
B.A 0wfqif&ef -0wfqif&ef -0wfqif&ef -0wfqif&ef -0wfqif&ef -
(1) Mask rS visor (rSef) udk clean vkyfyg/
(2) B.A udk0wfqif&ef harness udk fit jzpfatmif adjust vkyfyg/
(3) Cylinder valve rsm;udkzGifhjyD;? mask udkwyfyg/ Mask \tay:rS side straps ESpfckudk t&ifqGJwif;yg/ jyD;rS
atmufrS straps ESpfckudk qGJwif;yg/
(4) Demand valve ESifh exhalation valve rsm; properly function vkyfrvkyfod&ef avudk oHk;av;MudrfcefY deeply ½IoGif;^xkwfyg/
(5) Cylinder valve rsm;jyefydwfjyD; vufusefavr&Sdatmif ½Ixkwfyg/
(6) avudk jyif;pGm½Iyg/ xdktcg mask onf rsufESmwGif wif;MuyfpGmuyfvmvQif mask ESifh valve rsm; air tight
jzpfaMumif; odEdkifonf/
(7) Cylinder valve rsm;udk zGifhyg/ toHk;jyK&ef ready jzpfonf/
(xkwfvkyfol\ design t& B.A wpfckESifhwpfck operation uGmjcm;aomfvnf; principle rSm twlwlyif
jzpfonf/ xdkYaMumifh toHk;rjyKcif instruction udkaocsmpGmzwf&rnf/ Drill rsm;wGifvnf; pratice vkyfí familiar jzpfatmif toHk;jyKxm;oifhonf/)
International Shore Connection
(1) GT 500 ESifhtxuf oabFmwdkif;wGif tenf;qHk;wpfckyg0if&rnf/ (2) Either side of the ship wGif connect vkyfEdkif&rnf/
(3) Standard dimensions rsm;rSm atmufygtwdkif;jzpfonf/
Outside Diameter 178 mm
Inside Diameter 64 mm
Bolt Circle Diameter 132 mm
Bolt hole (4 ayguf) Diameter 19 mm
Bolt Diameter 16 mm
Bolt Length 50 mm
Flange Thickness 14.5 mm (Min.)
Gasket 1 pcs (Max: Pressure 1.0 N/mm2 )
Washers 8 pcs
(4) International Shore Connection udk Steel or other suitable material jzifhjyKvkyfjyD; 1.0 N/mm2 pressure udkcHEdkif&nf&Sd&rnf/
(5) International Shore Connection \ face wpfbufonf flat jzpfjyD; tjcm;wpfbufonf oabFmrS hydrant ESifh hose udk permanently attach vkyfEdkifap&rnf/
(6) ¤if;udk tjcm;udpötwGuf toHk;rjyK&? tvG,fwul&,lEdkifrnfhae&mrSm xm;&rnf/ (Bridge)
Fire Control Plan
(a) Ship's Officer rsm;udk Guidance ay;&ef oabFm\ Deck wdkif;wGif Fire Control Plan udk permanently
azmfjyxm;&rnf/ ¤if; Plan wGif atmufygtcsufrsm; yg&Sd&rnf/ (1) Control Stations
(2) A class division ESifh B class divisions [lí various fire section rsm;udk enclosed vkyfí
owfrSwfjcif;
(3) Particular of fire detection and fire alarm systems (4) Sprinkler installation
(5) Fire Extinguishing appliances.
(6) Means of access to different compartments & decks etc.
(7) The position of dampers and identification numbers of the ventilating fans serving each station rsm;yg0ifonf/
(b) tao;pdwf booklet pmtkyfwGif a&;om;azmfjy&rnf/
Copy rsm;udk officer wdkif;xHay;xm;&rnf/ ukrÜPDudkvnf; one set ay;&rnf/ One copy vlwdkif; tvG,fwuljrifEdkifwJhae&mwGifxm;&rnf/ (up to date)
Company oHk; language jzifhazmfjyxm; (Oyrm - English (or) French (odkY) translation vkyfay;xm;)&
rnf/
Deck House tjyifbufwGif water tight container (Bullet) aZmufxdk;xm;&rnf/ Gangway Entrance
2 bufpvHk;wGifxm;&rnf/ L.S.A, F.F.E xm;wJhae&mrsm;udkvnf;odEdkif&rnf/