• No se han encontrado resultados

[PDF] Top 20 Empleo de un biosorbente para el tratamiento de agua

Has 10000 "Empleo de un biosorbente para el tratamiento de agua" found on our website. Below are the top 20 most common "Empleo de un biosorbente para el tratamiento de agua".

JUNTA GENERAL ORDINARIA 2017

Evaluation of unilateral cage-instrumented fixation for lumbar spine

... Performing unilateral PLIF using a single interbody cage has several ...interbody cage through a unilateral approach compromises fewer anatomic structures than two cages inserted through a ... See full document

47

Sincronización del sistema de tracción del proceso de recubrimiento con polietileno de los coils que conforman los catéteres para la empresa Boston Scientific Costa Rica

The postoperative lumbar spine: enhanced MR evaluation of the intervertebral disk

... To eliminate any potential treatment bias, analysis was restricted to the control group of patients, who had no investigational device inserted into the laminectomy site at the time of surgery. All 94 patients in the ... See full document

94

Gênero, sexualidade e educação sexual: o que pensam os/as docentes

Ganglion cyst on the posterior cruciate ligament: a case report

... A 25-year-old male professional hockey player with right sided hip pain was diagnosed with myofascopathy of the right psoas major and rectus femoris. The patient maintained a conservative treatment regimen and was ... See full document

21

SINTESIS ESTATAL MIÉRCOLES 18 DE FEBRERO DE 2015

Is unilateral pedicle screw fixation superior than bilateral pedicle screw fixation for lumbar degenerative diseases: a meta-analysis

... screw fixation increases the stability of the spine, and it also increases the implant costs and the incidence of neurologic ...And, unilateral pedicle screw fixation was associated with an ... See full document

8

Montevideo, Octubre Ing. Agr. Ana Inés Antón

Modified posterior lumbar interbody fusion using a single cage with unilateral pedicle screws: a retrospective clinical study

... Posterior lumbar interbody fusion (PLIF) is widely per- formed for patients suffering from degenerative lumbar spine diseases, such as spinal stenosis, lumber spondylo- listhesis and lumber disc ... See full document

37

Para acceder al documento haz clic AQUÍ

The role of cage height on the flexibility and load sharing of lumbar spine after lumbar interbody fusion with unilateral and bilateral instrumentation: a biomechanical study

... long cage, unilateral instrumentation provided signifi- cantly lower flexibility than the cage alone configuration for the three tested motions, but offers higher flexibility than bilateral ... See full document

60

Pengaruh Service Quality terhadap Satisfaction dan Customer Loyalty Koperasi Dadirah di Dili Timor-Leste

Comparison of outcomes between cortical screws and traditional pedicle screws for lumbar interbody fusion: a systematic review and meta-analysis

... In lumbar interbody fusion, CS fix- ation and PS fixation can achieve a good fusion effect, and there is no statistically significant difference between the two ... See full document

34

Izquierdazos y derechazos contra la cultura de masas

Riding position and lumbar spine angle in recreational cyclists: a pilot study

... assess lumbar spine angle in three different cycling positions, and explored the relationship between lumbar spine angle and riding position, anthropometry, bike measures and low back pain ... See full document

10

Curso de posgrado: La filosofía de Andrew Feenberg Docente: Dra. Carolina Inés Araujo (UNT)

Transpedicular screw fixation in the thoracic and lumbar spine with a novel cannulated polyaxial screw system

... Sixty-seven consecutive thoracic and lumbar fusions were performed between May 2005 and September 2006. The procedures performed were: simple dorsal fusion, fusion with decompression of the spinal canal, and ... See full document

8

Las Precipitaciones y su relación con el  Balance Hídrico Superficial del sistema Hidrológico conformado por la cuenca del río Mishquiyacu, en el distrito de Pilluana, Provincia de Picota-Región San Martin

Algorhythm for Use of Percutaneous Short Fixation of Fractures Involving the Thoracolumbar Junction and Lumbar Spine

... The purpose of the decisional algorithm is to guide the surgeon in his choice between a percutaneous approach and open surgical instrumentation: its limits consist of the presence of oth[r] ... See full document

174

De doctorandos a doctores : la productividad de programas doctorales en distintos campos disciplinares

Patient demographics and MRI based measurements predict redundant nerve roots in lumbar spinal stenosis: a retrospective database cohort comparison

... The preoperative data of 300 consecutive LSS patients who underwent single- or multi-level microsurgical bilat- eral decompression via a unilateral approach (also known as “ cross over ” or “ over the top ” ... See full document

101

UN ENFOQUE EDUCATIVO PARA LA ENSEÑANZA DEL DISEÑO Y LA COMUNICACIÓN VISUAL.

Biomechanical comparison of anterior lumbar interbody fusion: stand alone interbody cage versus interbody cage with pedicle screw fixation a finite element analysis

... the spine is relatively simple compared to that in posterolateral fusion ...a cage is widely used to maintain the height of the intervertebral discs and to restore the stability of the spinal ...screw ... See full document

12

El Radicalismo y la política santafesina en la Argentina de la primera república

Robot assisted midline lumbar fusion with cortical bone trajectory screw

... lumbar degenerative disease, including lumbar spondylolisthesis, lumbar stenosis. 29 patients are assisted by 3D-fluroscopy real time navigation(Styker). 26 patients use the Robot assisted technique. ... See full document

24

mhtml:file://c:\documents and Settings\mloizux\Escritorio\DAL 05-JUL-07 (2-AL)...

Morphological changes of contralateral intervertebral foramen induced by cage insertion orientation after unilateral transforaminal lumbar interbody fusion

... spondylolistheses, recurrent disc herniation, spinal stenosis with segmental instability, and discogenic back pain that is unresponsive to conservative treatment [3 – 5]. TLIF has many advantages over other infusion ... See full document

7

Balmaceda y la izquierda Chilena : una mirada al partido comunista y el partido socialista a partir del imaginario político Balmacedista, Chile 1938-1973

Biomechanical comparison of a novel transoral atlantoaxial anchored cage with established fixation technique a finite element analysis

... fusion cage filled with bone graft was inserted into the C1-2 joint in a direction parallel to the sagittal ...After cage placement, a suitable TARP plate was rigidly fixed to screws from C1 to C2 to ... See full document

171

MIDDLETOWN TOWNSHIP PUBLIC SCHOOLS Office of School Business Administrator P.O. Box 4170 Middletown, NJ Tel: Fax:

Pressure distributions inside intervertebral discs under unilateral pedicle screw fixation in a porcine spine model

... the unilateral pedicle screw fixation and the force of the spine was not fully ...whole spine could not be fully ...whole spine and the difference between bilateral and ... See full document

8

Reinventar el Gobierno: problemas y perspectivas

SPINAL MOBILITY IN GRADUATED PHYSIOTHERAPIST

... cervical spine and lumbar spine, to compare the acquired data with the normative data of spinal range of motion for cervical and lumbar spine and to find out the incidence of deviation ... See full document

16

INCIDENCIA DE DOS CAMPAÑAS EN REDES SOCIALES EN LA IMAGEN CORPORATIVA DE CLARO ECUADOR

Original Article Clinical outcomes and cost analysis for unilateral versus bilateral pedicle screw fixation in two levels during minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF): a comparative analysis

... or unilateral TLIF procedure for the treatment of degenerative lumbar ...of unilateral pedicle screw (UPS) versus bi- lateral pedicle screw (BPS) in degenerative lumbar diseases after ... See full document

32

La biblioteca en el telfono mvil

Biomechanical Analysis of Fusion Segment Rigidity Upon Stress at Both the Fusion and Adjacent Segments: A Comparison between Unilateral and Bilateral Pedicle Screw Fixation

... screw fixation models, both the UF-HL and UF-TL models demonstrated ...the unilateral fixation models demonstrated dif- ferent increments in AF stress related to the extent of de- ... See full document

9

Norma de calidad de mora despitonada

Comparative analysis of posterior lumbar interpedicular screw fixation using x ray versus navigation or intraoperative CT spine

... J Bone Joint Surg Am. 2017 Mar 1;99(5):365-372. doi: 10.2106/JBJS.16.00230.Role of Weekly Teriparatide Administration in Osseous Union Enhancement within Six Months After Posterior or Transforaminal Lumbar ... See full document

14

Show all 10000 documents...