Has 10000 "Sistema Contable basado en NIIF para PYMES en la empresa IMPEXCA S.A en el municipio de Matagalpa, en el I semestre del año 2015." found on our website. Below are the top 20 most common "Sistema Contable basado en NIIF para PYMES en la empresa IMPEXCA S.A en el municipio de Matagalpa, en el I semestre del año 2015.".
Single-Stage Power Electronic Converters with Combined Voltage Step-Up/Step-Down Capability
... output voltage and it can be a forward, a flyback or any other step down isolated dc-dc ...two converters to perform AC/DC conversion, single-stage converters have been ... See full document
18
Design and Implementation of New Resonant Step Down/Up Converters
... converter power density. This conditionis commonly attained by zero voltage switching (ZVS) and zero current switching ...type converters include the basic pulse width modulation (PWM) buck-boost and ... See full document
12
Dual Step-Up Converter Fed with Single Stage CC-CSI with High Voltage Gain
... dual step-up converter fed with single stage capacitor commutated current source inverter with high voltage ...context, power electronics performs important tasks making viable ... See full document
11
Coupled Inductor based Interleaved Boost Converter for Enhanced Time Response
... energy power conversion systems in industrial applications are Efficiency, power quality, and ...photovoltaic power stations. The power conversion of the photovoltaic system is divided into ... See full document
98
High Power Factor Bridgeless SEPIC Rectifier for Drive Applications
... converter stage also suffers from many limitations like, large sized EMI filter, input–output isolation cannot be implemented easily, larger PFC inductance, high start up inrush current, and there is a lack ... See full document
18
PV Cell Fed High Voltage Gain Coupled Inductor Based Input Parallel Output Series DC-DC Converter for Grid Connected System
... high step-up gain is the use of the voltage-lift technique, showing the advantage that the voltage stress across the switch is ...the single switch may suffer high current for high ... See full document
43
PV Cell based Single Stage Step-Up or Step-Down DC–AC Converter
... dc–ac converters whose main feature is its capacity to provide an instantaneous output voltage higher or lower than the input voltage without an intermediate power stage or ... See full document
47
An Integrated Step-Down Converter Using Single-Stage Single-Switch Double Buck Converter
... dc voltage to feed their loads, but also a high-input power factor(PF) to reduce harmonic distortion in the current drawn from the electric power ...the power electronics field and ... See full document
12
Single Phase Bridgeless Zeta PFC Converter with Reduced Conduction Losses
... years, single phase ac-dc PFC converters have received much attention due to the dramatic growth in the use of electronic equipment and these ac-dc converters introduce harmonic ...lower ... See full document
98
A Novel Bidirectional DC-DC Converter with Battery Protection
... low voltage stresses across the switches, higher step-up and step-down voltage gains and efficiency is also high when compared to conventional boost/buck ...the ... See full document
102
High Step-Up Power Conversion for Photovoltaic Applications.
... stable power supply to the load, (iii) act as an emergency energy source when the primary sources are ...respectively. Combined with a rectifier or an inverter, the battery can achieve AC-DC or DC-AC ... See full document
14
Harvesting electrical energy from a stationary bike : an experimental approach : a thesis presented in partial fulfillment of the requirements for the degree of Master of Engineering in Electronics and Computer Systems Engineering, School of Engineering and Advanced Technology, Massey University, Palmerston North, New Zealand
... set up for optimum EH and modifications were made as ...and power output recorded, the findings showed that while energy was harvested the quantity was not ...a step in research, in the journey ... See full document
78
High Boost Converter and Hybrid Cascaded H Bridge Inverter for Photovoltaic System
... in power electronics technologies the renewable energy sources utilization become an increasing trend for electrical ...in power system and power ...output voltage of DC/DC converter and ... See full document
56
Maximum Boost Control of Step up-Step down Voltage Source Converter with X-Shape Diode-Capacitor Network
... line voltage by controlling the front boost ...less power device requirement and higher efficiency in high voltage gain ...dc/ac voltage regulation in renewable energy ...capacitor ... See full document
49
Implementation of Multi level inverter for SEPIC Converter with Grid Connected PV System
... m power tracking for PV panel using DCDC converter is developed [10] without using ...maximum power transfer under all atmospheric ...electric power for longer time , than a crystalline si solar cell ... See full document
15
Review of High Step up Converter with Voltage Multiplier for Photovoltaic System
... provide step up conversion without high gain due the limitation of conduction losses in the circuit ...the power electronic devices connected. The voltage gain is difficult to obtain ... See full document
64
Learning a Deep Hybrid Model for Semi Supervised Text Classification
... To directly handle the problem of discriminative learning when labeled data is scarce, (Ororbia II et al., 2015) proposed deep hybrid architectures that could effectively leverage small amounts of labeled and large ... See full document
146
A NOVEL High Step-Up Converter with a Voltage Multiplier Module for a Photovoltaic System
... high step-up interleaved converter introduced in is also suitable as a candidate for high step-up, high-power conversion of the PV system, and the other high step-up ... See full document
59
Creating Entrepreneurship in Skill based Educational Institutes in Western Maharashtra
... array voltage is periodically incremented or decremented, till MPPT is ...array power, the subsequent perturbation is made in the same (or opposite) ...peak power tracker continuously hunts or seeks ... See full document
15
Digital Testing Kit For Three Phase Distribution Transformer
... 36V supply is given to op-am LM358 through the transformer, this 36V supply will step down at next op-am IC741 which acts as zero crossing detector. Property of IC 741 is to convert the sinusoidal wave into ... See full document
23
Related subjects