[PDF] Top 20 Relación entre funciones ejecutivas, atención selectiva y consumo de sustancias Psicoactivas en estudiantes
Has 10000 "Relación entre funciones ejecutivas, atención selectiva y consumo de sustancias Psicoactivas en estudiantes" found on our website. Below are the top 20 most common "Relación entre funciones ejecutivas, atención selectiva y consumo de sustancias Psicoactivas en estudiantes".
Comparison of three different fixation constructs for radial neck fractures: a biomechanical study
... the biomechanical results for this fix- ation method are ...the radial head and neck fracture is less than for the plate fixation ...the radial head and although the wound exposure is ... See full document
13
Biomechanical efficacy of AP, PA lag screws and posterior plating for fixation of posterior malleolar fractures: a three dimensional finite element study
... and fixation can be achieved by antero-posterior (AP) lag ...internal fixation is maintained either by postero-anterior (PA) lag screws or by posterior ...the different fixation ...comparative ... See full document
10
The effect of different screw rod design on the anti rotational torque: a biomechanical comparison of three conventional screw rod constructs
... included different conventional spinal screw-rod fixation systems (Legacy, Medtronic ...preliminary study (for testing the machine and adjusting the custom jig before the experiment), and the ... See full document
27
Comparison of three different internal fixation implants in treatment of femoral neck fracture—a finite element analysis
... come. Biomechanical and laboratory studies suggest that although a sliding hip screw provides greater resistance to shearing force (the major cause of implant failure par- ticularly in displaced and unstable ... See full document
15
Biomechanical comparison using finite element analysis of different screw configurations in the fixation of femoral neck fractures
... research, biomechanical behaviors of five different configurations of screws used for stabi- lization of femoral neck fracture under axial loading have been examined, and which configuration is best ... See full document
25
Effect of different orientations of screw fixation for radial head fractures: a biomechanical comparison
... ics study; Synbone brand models was well represented in the hand and upper extremity biomechanics ...our biomechanical experiments, the divergent screw group showed the highest axial compression stiffness ... See full document
37
Biomechanical analysis of the annular ligament in Monteggia fractures using finite element models
... The commonly accepted pathogenesis of the Monteggia fracture is that the extended elbow with the olecranon is compressed by the humeral fossa after the distal end of the forearm touches the ground [1,2]. Bearing this in ... See full document
20
Open reduction and internal fixation with bone grafts for comminuted mason type II radial head fractures
... internal fixation for a closed Mason type II radial head fracture were retrospectively ...II fractures treated without bone grafting were ...the radial head fracture was achieved in all ... See full document
41
Maximizing outcomes in the treatment of radial head fractures
... the radial head in cases of comminuted radial head fractures, given the good functional outcomes and low complication rate with these ...after fixation or replacement of the radial head ... See full document
8
Radial neck fracture presenting to a Chiropractic clinic: a case report and literature review
... condition. Fractures of the radial head are relatively ...all fractures, between 1.5 and 4.5 percent of fractures in adults, and approximately one third of all fractures of the elbow ... See full document
15
Biopolymer augmentation of the lag screw in the treatment of femoral neck fractures - a biomechanical in-vitro study
... fracture fixation with a hip screw has been studied clinically and biomechanically [12, 15, ...unstable fractures classified as type A2 and A3 by the Ao classification is a ... See full document
16
MINI OPEN APPROACH FOR INTERNAL FIXATION OF RADIAL HEAD FRACTURES
... Mini-open fixation of radial head and fix the ...for fixation) Once the fracture is fixed the stability is checked under direct vision and image intensifier views are used for confirmation of the ... See full document
92
Ultrasonography guided reduction of pediatric radial neck fractures
... Steinmann pin. After satisfactory reduction was con- firmed on US, the radial head is buttressed by the thumb of the operator. We used fluoroscopy for in situ fixation with a second K-wire. The trajectory ... See full document
39
Surgical management of Hawkins type III talar neck fracture through the approach of medial malleolar osteotomy and mini-plate for fixation
... plane fractures of talus [3, ...talar neck fractures and includes three classifications based on initial fracture displace- ment: a non-displaced fracture (type I), a displaced frac- ture ... See full document
103
Comparison between minimally invasive, percutaneous osteosynthesis and locking plate osteosynthesis in 3 and 4 part proximal humerus fractures
... humeral fractures using either the PHILOS Plate (Synthes, Oberdorf, Switzerland) or the Humerusblock (Synthes, Oberdorf, ...humeral fractures (AO/OTA classification A3, B1-3, ...metaphyseal fractures ... See full document
173
Surgical treatment of zygomatic bone fracture using two points fixation versus three point fixation a randomised prospective clinical trial
... ful comparison. Displaced zygoma fractures are vulner- able to secondary malposition as a result of masticatory forces even after some kind of fixation ...zygomatic fractures is to restore and ... See full document
21
Comparison of Surgical Outcomes in Thoracolumbar Fractures Operated with Posterior Constructs Having Varying Fixation Length with Selective Anterior Fusion
... segment fixation but it was interesting to compare the correction values of KA between Group II and III after implant ...in comparison of Groups II and III, though it was statistically insignificant ... See full document
13
Clinical and radiological outcome analysis of neck of femur fractures treated with bipolar hemiarthroplasty: An Institutional study
... The ascending cervical branches arise from the extra-capsular arterial ring. Anteriorly they penetrate the hip joint capsule at the intertrochanteric line and posteriorly they pass beneath orbicular fibres of the ... See full document
20
Suboptimal outcomes after closed reduction and internal fixation of displaced femoral neck fractures in middle aged patients: is internal fixation adequate in this age group?
... Femoral neck fractures (FNFs) are an important health concern, with multiple causes, such as trauma, malig- nancy, and bone metabolism ...stress fractures should be especially considered in ath- ... See full document
28
Original Article Comparison of the biomechanical function and clinical effects of plate and multi-pin fixation in the treatment of Sanders II calcaneal fractures
... pin fixation was that surgeons usu- ally put patients in plantar flexed position and then neutral position due to the concern for pin fixation stability in ...this study, the von Mises stress was ... See full document
7
Related subjects