[PDF] Top 20 Benevolo Leonardo - Historia de La Arquitectura Moderna
Has 10000 "Benevolo Leonardo - Historia de La Arquitectura Moderna" found on our website. Below are the top 20 most common "Benevolo Leonardo - Historia de La Arquitectura Moderna".
Outcome of 2 cc pure sulfur hexafluoride gas tamponade for macular hole surgery
... of macular hole, and pre- operative lens ...age, macular hole diameter, BCVA and ...by 2 or more lines on the Snellen VA chart at 6 months follow-up while anatomical success was de- ... See full document
27
PIMS (Positioning In Macular hole Surgery) trial – a multicentre interventional comparative randomised controlled clinical trial comparing face down positioning, with an inactive face forward position on the outcome of surgery for large macular holes: study protocol for a randomised controlled trial
... Random allocation to the alternatives of face-down or face-forward positioning presents a possible ethical issue because of the uncertainty over which is safer and more effective. In particular, there is some concern ... See full document
7
Audit of Macular Hole Surgery, Visual Outcome Prediction on OCT Appearance of Macular Hole
... The selection of patients was from a consecutive group of patients undergoing the same procedure was performed as a standard. Selection of 25 gauge pars plant vitrectomy, C2F6 (16%), internal limiting membrane peel with ... See full document
332
Efficacy of autologous platelets in macular hole surgery
... and gas temponade followed by FDP for 10 ...anatomical outcome if the surgical technique was accompanied by ILM ...the macular holes corresponds to the minimum diameter of the macular ... See full document
25
Macular hole surgery: an analysis of risk factors for the anatomical and functional outcomes with a special emphasis on the experience of the surgeon
... after surgery with a mean postoperative visual acuity of ...visual outcome of the surgeons in group I/surgeons with 0–3 years of experience compared to group IV/surgeons with 6 years of experience was ... See full document
11
Positioning In Macular hole Surgery (PIMS): statistical analysis plan for a randomised controlled trial
... In Macular hole Surgery) trial, a multicentre, interventional, comparative, randomised controlled clinical trial comparing face-down with face-forward positioning on the outcome for ... See full document
166
Patient adherence to the face-down positioning after macular hole surgery
... All the patients who had signed consent forms for the surgery and FDP received instructions on FDP. Pars plana vitrec- tomy was performed by experienced surgeons. Further, each patient also underwent ... See full document
13
Sulfur hexafluoride (SF6) versus perfluoropropane (C3F8) tamponade and short term face-down position for macular hole repair: a randomized prospective study
... after surgery, all the patients underwent a complete ophthalmic exami- nation, including best corrected visual acuity (BCVA), Goldman applanation tonometry, fundus examination and optical coherence tomography ... See full document
54
Functional and morphological results of treatment of macula-on and macula-off rhegmatogenous retinal detachment with pars plana vitrectomy and sulfur hexafluoride gas tamponade
... Sixty-two patients with RRD were included in this prospect- ive study from March 2016 to October 2017 in the Depart- ment of General Ophthalmology in Lublin, Poland. The study was performed in accordance with the ... See full document
12
Primary rhegmatogenous retinal detachment with inferior retinal breaks postoperative prone positioning results: 1 day versus 7 days
... after surgery when a gas tamponade is used is considered essential for achieving success in retinal detachment (RD) ...after surgery owing to medical, physical, or social ...a tamponade ... See full document
69
<p>Hybrid 23/27 Gauge Vitrectomy – Combining the Charm of 27G with the Efficacy of 23G</p>
... vitrectomy surgery systems with a valved cannula, 24 as well as commercially available double-cutting probes with constant fl ow properties 25 at standard cutting rates of 2500 cpm (23G) and 8000 cpm (27G and ... See full document
8
Quantifying metamorphopsia with M-CHARTS in patients with idiopathic macular hole
... thickness macular hole treated surgically and followed up for 6 months at the Kyushu University Hospital between June 2012 and May ...SF6 gas tam- ... See full document
66
Preparation and Application of TiO2 Nanotube Array Gas Sensor for SF6 Insulated Equipment Detection: a Review
... between gas response and concentration, it is found that the change between them presents a fitting curve ...of gas ac- cording to the corresponding gas ... See full document
10
Occult choroidal neovascularization after successful macular hole surgery treated with ranibizumab
... (C3F8) gas tamponade were performed to treat the macular hole of the right ...for 2 weeks postoperatively. One month after the surgery, fluid accumulation under the macula and ... See full document
14
Long term result of silicone oil versus gas tamponade in the treatment of traumatic macular holes
... The internal limiting membrane (ILM) was removed, using Eckardt end-gripping pick forceps, pinching the ILM about 2 disc diameters away from the foveal centre. Rhexis of the ILM was done leaving the foveal side ... See full document
12
Adherence to the face down positioning after vitrectomy and gas tamponade: a time series analysis
... the surgery. Although the nurses continued these examinations until the gas disappeared or the patient was discharged, we included only the first three consecutive days postsurgery in our initial study [34, ... See full document
27
<p>Emulsification of Different Viscosity Silicone Oil in Complicated Retinal Detachment Surgery: A Randomized Double-Blinded Clinical Trial</p>
... SO tamponade at the KKU Eye Center, Department of Ophthalmology, Faculty of Medicine, Khon Kaen University, Khon Kaen, Thailand from 2016 to 2018 were recruited into the ... See full document
12
Distribution of Electrical Power Using GIS
... or gas insulated switchgear system available for the high voltage, only SF6 (sulphur hexafluoride) is used both for interruption medium and insulation because dielectric strength is so excellent of ... See full document
62
Effect of sulfur hexafluoride gas and post annealing treatment for inductively coupled plasma etched barium titanate thin films
... microelectronic silicon-based devices involving BTO films, dry etching processes should be developed [10,11]. However, there is currently no feasible technology known for the etching of BTO films. In addition, the data ... See full document
30
Adherence to face-down and non-supine positioning after macular hole surgery
... In the same period, patients with MHs ≥400 μm in diameter, which were thought to be difficult to close [29, 36] were treated with a different surgical tech- nique using the inverted inner limiting membrane flap [9, 37]. ... See full document
6
Related subjects